| Nr |
订货号 |
规格 |
| |
|
Please return the unit to PC for repair |
| 1 |
71076316 |
电源适配器12VDC/2500mA LEMO接口 |
| 2 |
71094796 |
接线端子 |
| |
50091703 |
常温型声速传感器
Sound velocity measuring sensors for
Prosonic Flow 93; sensor pair for
measurement of sound velocity in the
fluid.
|
| |
50091704 |
高温型声速传感器
Sound velocity measuring sensors for
Prosonic Flow 93; sensor pair for
measurement of sound velocity in the
fluid.
|
| |
71112217 |
传感器 DDU 20
Wall thickness measuring sensor for
Prosonic Flow 93T; sensor for measuring
pipe wall thickness.
|
| |
|
Overview auxiliary equipment
see spare part picture |
| |
93TA1- |
便携式超声波流量计 93T
Battery operated Ultrasonic Flowmeter
set incl. datalog function with
time stamp, 1 GB USB Stick
carry case, charger, battery pack
acoustic couple medium
8 hours continious operation.
| P Sensor set DN15-DN65 1/2-2 1/2"/6MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...100oC/-40...212oF + installation set |
| C |
-40...150oC/-40...302oF + installation set |
| P Sensor set DN50-DN300 2"-12"/2MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...80oC/-40...176oF + installation set |
| C |
0...170oC/32...338oF + installation set |
| P Sensor Set DN100-DN4000 4"-160"/1MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...80oC/-40...176oF + installation set |
| Sensor Cable: |
| 9 |
Special version, TSP-no. to be spec. |
| E |
5m/15ft, PTFE, -40...170 oC/-40...338oF |
| F |
10m/30ft, PTFE, -40...170 oC/-40...338oF |
| Approval: |
| A |
Non-hazardous area |
| E |
Non-hazardous area + EAC marking |
| Operation language: |
| A |
WEA = DE+EN+FR+IT+ES+PT+NL |
| C |
SEA = JA+ID+EN |
| E |
EES = SV+FI+NO+RU+PL+CS+EN |
| G |
CN = ZH+EN |
| >>Sound velocity sensor set: |
| D1 |
DN50-DN3000 2"-180" |
| >>Wall thickness sensor: |
| E2 |
>DN15 1/2" |
| >>Additional Test, certificate: |
| F1 |
Verification DN50 2", sensor DN15-DN65 1/2"-2 1/2" |
| F2 |
Verification DN100 4", sensor DN50-DN300 2"-12" |
| F3 |
Verification DN100 4", sensor DN100- DN4000 4"-160" |
| >>Accessory: |
| P1 |
Cable 93T - FXA193 |
| P2 |
Car charging adapter cable |
| P3 |
Rechargable battery pack 93T, 4000 mAh |
| P4 |
Installation set <4000 160" <80°C |
| P5 |
Cable 93T - FXA291 |
|
| |
DK9PT- |
超声波93T,流量计传感器
For use with Prosonic Flow 93T
portable transmitter
| P sensor: |
| 1 |
DN15-DN65, -40...100oC, 6.0MHz 1/2…2 1/2", -40…212oF |
| 2 |
DN15-DN65, -40...150oC, 6.0MHz 1/2…2 1/2", -40…302oF |
| 9 |
special version, TSP-no. to be spec. |
| A |
DN100-DN4000, -40...80oC, 1.0MHz 4…169", -40…176oF |
| B |
DN50-DN300, -40...80oC, 2.0MHz 2…12", 40…176oF |
| F |
DN50-DN300, 0...170oC, 2.0MHz 2…12", 40…176oF |
| Approval: |
| A |
non-hazardous area |
|
| |
DK9SS- |
超声波91/93/93T,传感器电缆
| Transmitter: |
| C |
Prosonic Flow 93T |
| Sensor Type: |
| E |
93T, P sensor |
| Sensor cable: |
| E |
5m/15ft, PTFE, -40...170oC/-40...338oF |
| F |
10m/30ft, PTFE, -40...170oC/-40...338oF |
|
| |
DK9SH- |
W/P型 传感器座组件 DK9SH
| Sensor holder: |
| 2 |
Clamp On, portable DN15-DN65 1/2"-2 1/2" |
| 9 |
Special version, TSP-no. to be spec. |
| B |
Clamp On, detachable retaining nut W/P sensor DN50-DN4000 2"-160" |
|
| |
DK9ZT- |
便携式超声波93T附件(含电池组,安装组件等)
| Accessorie: |
| 1 |
Cable 93T - FXA193 |
| 2 |
Car charging adapter cable |
| 3 |
Rechargeable battery pack 93T, 4000 mAh |
| 4 |
Installation set |
| 5 |
Installation set |
| 6 |
Sensor connector, adapter set W/P sensor |
| 7 |
USB Stick, 1GB |
| 8 |
Cable 93T - FXA291 |
| A |
Cable adapter, 93T to 93P DN15-65 Sensor |
| B |
Installation set |
| C |
Carrying bag |
|
| |
FXA193- |
通讯接口 FXA193
The service interface connects the
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
- Serviceinterface with RS 232C
connection cable (9 pin.)
- FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
- Service Softw.ToF Tool-Fieldtool
Package
| Approval: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
For use in non-hazardous area |
| B |
ATEX II (1) GD |
| C |
CSA/FM Class I Div. 1 |
| D |
ATEX, CSA, FM |
| Connection Cable: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
Proline device |
| B |
ToF device |
| E |
Proline and ToF device |
| F |
Ex two-wire device |
| G |
Proline device and Ex two-wire device |
| H |
Proline, ToF and Ex two-wire device |
| X |
Without connection cable |
|