Nr Order Number Specifications
F 50099250 PSONIC9X power module 85-260VAC
Kit power s. B. PSONIC9X 85-260VAC
F 50099252 flowmeter communication board
Kit P.s. B. PSONIC9X 20-55VAC16-62VDC
7 50094002 Fuse
Kit 10 fuses 250 VAC T800 MA
7 50094003 Fuse
Kit Bus/connec. B .5X/40/8X/65 field hous.
B 71093780 93 Amplification Module
Language: FR,ES,IT,NL,PT,DE,EN
B 71093781 Amplifier Board
Language: SV,FI,NO,RU,PL,CS,EN
B 71093783 Amplifier Board
Language: JA,ID,EN
B 71093785 93 Amplifier
Language: ZH,EN
B 71093786 Amplifier Board
Language: FR,ES,IT,NL,PT,DE,EN
B 71093787 Amplifier Board
Language: FR,ES,IT,NL,PT,DE,EN
B 71093788 Amplifier Board
Language: JA,ID,EN
B 71093789 93 Enlarging Plate EX
Language: ZH,EN
C 50098301 Explosion-proof current/frequency output module
Kit com 53/83/93/65 curr/freq. out Ex
C 50098300 explosion-proof current frequency/2 relay output module
Kit com 53/83/93/65 curr/freq/2Relay Ex
C 71066579 input/output board PA Ex
50/53/55/80/83/93/65
C 71107614 93 Profibus DP C13 explosion-proof communication module
D 50108002 Communication Module
53/55/83/93
C 50101264 Explosion-proof input/output board C02
Kit com Pline 53/83/93Found.Fieldbus Ex
C 71095035 input/output board C14 EX
53/55/83/93/65
D 50096833 explosion-proof output master with 3-way interface
Kit Com53/8X/93/65 curr.out 3 Interf.Ex
3 50096834 current output sub-module
Kit Sub PCB 53/8X/93/65 current out
3 50096834 current output sub-module
Kit Sub PCB 53/8X/93/65 current out
4 50096835 frequency output sub-module
Kit Sub PCB 53/8X/93/65 frequency out
4 50096835 frequency output sub-module
Kit Sub PCB 53/8X/93/65 frequency out
6 50096836 Relay Output Submodule
Kit Sub PCB Pline53/83/93 Relay out
6 50096836 Relay Output Submodule
Kit Sub PCB Pline53/83/93 Relay out
5 50096837 Status Input Submodule
Kit Sub PCB 53/8X/93/65 Status input
E 50096755 Wall-mounted display module
Kit display mod 53/83/84/93 Wall encl
10 50094017 wall-mounted plate clamping shell
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
8 50094014 Junction Module
Kit connec. board In/Output Wall encl
9 50099256 PSONIC90 wall-mounted terminal
Kit connec.plate PSONIC90 wall enclo.
9 50099257 PSONIC93 wall-mounted terminal
Kit connec.plate PSONIC93 wall enclo.
30 50108140 5X/8X/9X/65 wall-mounted wiring block
Kit Termin.Block Wall encl. 5X/8X/9X/65
2 50094004 Transmitter T-DAT Data Module
Kit T-DAT Transmitter Data Chip
12 50096840 cable plug
Kit 10 cable glands M20x1,5
12 50098042 Adapter
Kit 10 extension M20x1.5/NPT 1/2"
12 50098041 Adapter
Kit 10 extension M20x1.5/G 1/2"
12 50098037 PA master cable plug
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
12 50094984 FF master cable plug
Kit Cable gland Found. Fieldbus
50096841 Ground strap/lid locking buckle
Kit Ground terminal / Cover clamp
50098636 display (wall mounted)
11 50094041 Wall-mounted sealing cover
Kit Seal cover to Wall enclosure
FXA193-?? communication interface FXA193
The service interface connects
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
-Serviceinterface with RS 232C
connection cable (9 pin.)
-FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
-Service Softw.ToF Tool-Fieldtool
Package
DK9UI-??? Ultrasonic Flow Meter 93 Input/Output Module Conversion Assembly
A retrofit kit consists of
instruction sheet
meter documentation, retrofit label
connection
label and the exchangeable I /O modules.
50091703 Normal Temperature Sound Velocity Sensor
Sound velocity measuring sensors
Prosonic Flow 93; sensor pair
measurement of sound velocity in
fluid.
50091704 high temperature sound velocity sensor
Sound velocity measuring sensors
Prosonic Flow 93; sensor pair
measurement of sound velocity in
fluid.
50091713 wall thickness sensor
Wall thickness measuring sensor
Prosonic Flow 93; sensor for measuring
pipe wall thickness.
Overview auxiliary equipment
see spare part picture
93XXX- Prosonic 93 Transmitter S93XXX
Application:
XX1 Sensor W/P, 1-channel
XX2 Sensor W/P/U/C-Inline, 2-channel
Version:
XXX Transmitter only
Approval:
9 Special version, TSP-no. to be spec.
A Non-hazardous area
R FM NI Cl. I Div.2/CSA Cl. I Div. 2, ABCD Zone 2
Housing:
C Remote, wall, Aluminium, IP67 NEMA4X
Cable Entry Sensor:
9 Special version, TSP-no. to be spec.
A M20x1.5 cable gland; thread for cable gland for EEx d version
B Thread NPT 1/2
C Thread G 1/2
K Bus plug gland M20
L Bus plug thread NPT 1/2
M Bus plug thread G 1/2
Power Supply; Display:
7 85-260VAC; WEA, w/o display, Remote configuration WEA= language DE EN FR IT ES PT NL
8 20-55VAC / 16-62VDC; WEA, w/o display, Remote configuration WEA= language DE EN FR IT ES PT NL
9 Special version, TSP-no. to be spec.
A 85-260VAC; WEA, 4-line touch control WEA= language DE EN FR IT ES PT NL
B 20-55VAC / 16-62VDC; WEA, 4-line Touch control, WEA= language DE EN FR IT ES PT NL
C 85-260VAC; SEA, 4-line touch control SEA= language JA ID EN
D 20-55VAC / 16-62VDC; SEA, 4-line Touch control, SEA= language JA ID EN
E 85-260VAC; EES, 4-line touch control EES= language SV FI NO RU PL CS EN
F 20-55VAC / 16-62VDC; EES, 4-line Touch control, EES= language SV FI NO RU PL CS EN
G 85-260VAC; CN, 4-line touch control, CN= language ZH EN
H 20-55VAC/16-62VDC; CN, 4-line Touch control, CN= language ZH EN
Adjustment; Software Feature:
A Factory Setup; Basic Version
E ***Factory Setup; Advanced diagnostics
Output, Input:
2 4-20mA HART 4-20mA freq. relay M= modules exchangeable
4 4-20mA HART 4-20mA 2x freq. M= modules exchangeable
6 4-20mA HART 4-20mA 2x relay M= modules exchangeable
9 Special version, TSP-no. to be spec.
A 4-20mA HART frequency
B 4-20mA HART freq. 2x relay
C 4-20mA HART freq. 2x relay M= modules exchangeable
D 4-20mA HART freq. relay stat.In M= modules exchangeable
H PROFIBUS PA
J PROFIBUS DP
K FOUNDATION Fieldbus
L 4-20mA HART 2x relay stat.In M= modules exchangeable
M 4-20mA HART 2x freq. stat.In M= modules exchangeable
P PROFIBUS DP 20mA freq. stat.In M= modules exchangeable
V PROFIBUS DP 2x relay stat. In M= modules exchangeable
W 4-20mA HART 2x 20mA relay M= modules exchangeable
DK9WS- W Sensor Assembly
For use
Prosonic Flow 90/91/92T/93
Application:
1 DN15-DN65, -20…80oC, IP67, 6.0MHz Clamp On, 1/2-2 1/2", -4…176oF, NEMA4X
3 DN15-DN65, -20…80oC, IP68, 6.0MHz Clamp On, 1/2-2 1/2", -4…176oF, NEMA6P
9 Special version, TSP-no. to be spec.
A DN100-DN4000, -20...80oC, IP67, 1.0MHz, Clamp On, 4"-160", -4...176oF, NEMA4X
B DN50-DN300, -20...80oC, IP67, 2.0MHz, Clamp On, 2"-12", -4...176oF, NEMA4X
K DN200-DN4000, -40...80oC, IP68, type B Insert, 8"-160", -4...176oF, NEMA6P
M DN100-DN4000, -20...80oC, IP68, 1.0MHz, Clamp On, 4"-160", -4...176oF, NEMA6P
N DN50-DN300, -20...80oC, IP68, 2.0MHz, Clamp On, 2"-12", -4...176oF, NEMA6P
R DN100-DN4000, -20...80oC, IP67, 0.5MHz, Clamp On, 4"-160", -4…176oF, NEMA4X
T DN100-DN4000, -20...80oC, IP68, 0.5MHz, Clamp On, 4"-160", -4…176oF, NEMA6P
Approval:
9 Special version, TSP-no. to be spec.
A Non-hazardous area
R FM NI Cl. I Div.2/CSA Cl. I Div. 2, ABCD Zone 2
DK9SS- Ultrasonic 91/93/93T, sensor cable
Transmitter:
B Prosonic Flow 93
Sensor Type:
A W/P Clamp On DN15-DN65 1/2"-2 1/2"
B W/P Clamp On DN50-DN4000 2"-160"
C W Insertion
Sensor cable:
9 special version, TSP-no. to be spec.
A 5m/15ft, -20...70oC/-4...158oF
B 10m/30ft, -20...70oC/-4...158oF
C 15m/45ft, -20...70oC/-4...158oF
D 30m/90ft, -20...70oC/-4...158oF
E 5m/15ft, PTFE, -40...170oC/-40...338oF
F 10m/30ft, PTFE, -40...170oC/-40...338oF
G 15m/45ft, PTFE, -40...170oC/-40...338oF
H 30m/90ft, PTFE, -40...170oC/-40...338oF
DK9SH- W/P Type Sensor Block Assembly DK9SH
Sensor holder:
1 Clamp On, DN15-DN65 1/2"-2 1/2"
9 Special version, TSP-no. to be spec.
A Clamp On, fixed retaining nut, W/P sensor DN50-DN4000 2"-160"
B Clamp On, detachable retaining nut W/P sensor DN50-DN4000 2"-160"
C Insertion, DN200-DN300 8"-12", 1-channel
D Insertion, DN300-DN400 12"-16",1-channel
E Insertion, DN400-4000 16"-160",1-channel
F Insertion, DN400-4000 16"-160",2-channel
DK9IC- W/P Type Bundled Sensor Mounting Assembly DK9IC
Only use with Prosonic Flow 91 and 93
transmitter.
Strapping band:
1 DN15-DN32 1/2"-1 1/4" (U-bolt), W/P sensor DN15-DN65 1/2"-2 1/2"
2 DN40-65 1 1/2"-2 1/2" W/P sensor DN15-DN65 1/2"-2 1/2"
9 Special version, TSP-no. to be spec.
A Not selected
B DN50-DN200 2"-8" W/P sensor DN50-DN4000 2"-160"
C DN200-DN600 8"-24" W/P sensor DN50-DN4000 2"-160"
D DN600-DN2000 24"-80" W/P sensor DN50-DN4000 2"-160"
E DN2000-DN4000 80"-160" W/P sensor DN50-DN4000 2"-160"
Application:
1 Not selected
2 Spacing ruler DN50-DN200 2"-8" , W sensor DN50-DN4000 2"-160"
3 Spacing ruler DN200-DN600 8"-24" , W sensor DN50-DN4000 2"-160"
6 Fastening, 1 traverse, W/P sensor DN50-DN4000 2"-160"
9 Special version, TSP-no. to be spec.
DK9II- W-type plug-in sensor mounting assembly DK9II
Only use with Prosonic Flow 90 and 93
transmitter.
Application:
9 Special version, TSP-no. to be spec.
A DN100-1800 4"-72", insertion
B DN1800-4000 72"-160", insertion
DK9CB- Ultrasonic flow meter 91/93 W/P, pipe adapter
Transmitter:
B Prosonic Flow 93
Sensor type:
A W/P Clamp On DN15-DN65 1/2"-2 1/2"
B W/P Clamp On DN50-DN4000 2"-160"
C W Insertion
Cable entry:
0 Without conduit adapter sensor cable glands
1 Conduit adapter M20x1.5 sensor cable glands
2 Conduit adapter NPT1/2" sensor cable glands
3 Conduit adapter G1/2" sensor cable glands
DK9WM- 90/93 Transmitter Mounting Assembly DK9WM
Application:
A Remote 90/93 wall/ pipe mounting, panel
DK9SO- 93 Software Package DK9SO
Software kit
Software Feature:
A Advanced diagnostics
DK9CM- Couplant DK9CM
Usage:
Prosonic Flow 91W/93W/93P
Version:
1 ***Coupling medium Wacker P, -40...80oC/ -40...175oF
2 Coupling medium -40...170oC/-40...338oF, standard
3 Adhesive coupling medium -40...80oC/ -40...176oF
4 Water soluble coupling medium -20..80oC/ -4...176oF
5 ***Silgel -40...l30oC/-40...265oF
6 Coupling medium DDU19 DDU20 -20...60oC/ -4...140oF
7 Coupling medium -40...100oC/-40...212oF standard, type MBG2000
8 Pad, FPM, 0...170oC/32...338oF
A 2x permanent coupling pad, -40… 100oC/ -40… 212oF, 0.5MHz, 1MHz, 2MHz
B 2x permanent coupling pad, -40… 170oC/ -40… 338oF, 0.5MHz, 1MHz, 2MHz
C 1x permanent coupling pad, -40… 100oC/ -40… 212oF, 5MHz
D 1x permanent coupling pad, -40… 170oC/ -40 ...338oF, 5MHz