Nr Order Number Specifications
C 60000516 Oval Flange
Maximum temperature 400oC DIN 43734
Material in cast iron
Mating flange and gasket not provided.
Dimension: A=23mm, C=90mm, B =70mm
60020836 ferrule thread
Maximum temperature 350oC
Maximum pressure 1 bar.
Material in stainless steel
Dimension: A=G 3/4", d=22mm, Wr=41
60021425 ferrule thread
Maximum temperature 350oC
Maximum pressure 1 bar.
Material in stainless steel
Dimension: A=G1"1/2, d=22mm, Wr=55
60021757 ferrule thread
Maximum temperature 350oC
Maximum pressure 1 bar.
Material in stainless steel
Dimension: A=G1", d=22mm, Wr=41
71182602 seal
5x O-ring 3.69x 1.78
5x 0-ring 74.7x2.75
71044061 Device Pack
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector
A TA20A- **Junction box TA20A
Product being phased out
limited availability.
Connection head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material: Aluminium epoxy resin coating
Area temperature : max. 100 oC;
ATEX: 95 oC.
A
5
A
1
A TA30A- lug TA30A
Retainer for terminal block or head
transmitter optional display.
Cover: low, hinged, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
A
C
1
A TA30D- lug TA30D
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
C
D
B TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
A1
UR
A
2
A
D1
D2
B TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
A1
UR
A
2
A
D1
D2
F2
MY
NA
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
TXU10- Instrument debugging package TXU10
for PC-programmable devices
The program sets the connection line for a PC with USB interface
AA
AC
AD
TMT71- temperature transmitter TMT71
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC.
AA
UR
A
P
1
A
AB
A1
B4
CK
CT
CU
TMT72- temperature transmitter TMT72
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification: Pt100, 4-wire, 0... 100oC
AA
UR
A
P
1
A
AB
A1
B4
CK
CT
CU
B TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Presetting failure current high.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
AA
UR
A
2
A
D1
D2
D3
TB
TR
TS
AA
TB
TR
TS
A1
A2
H2
LA
NA