Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FTL71 音叉限位开关

FTL71 音叉限位开关

音叉限位开关

Liquiphant FTL71 is a point level switch with extension tube for use in hazardous areas with all international certificates. FTL71 is especially designed for applications with high process temperatures up to 280°C and can be used up to SIL2, in homogeneous redundancy up to SIL3. An integrated second line of defense offers the highest degree of safety. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Compare

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application Modular housing concept
High process temperatures up to 280°C
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g. Ex,WHG)
compact, e.g. pipes
Dual Sealing / Second line of defense
Specialities Foam detection
Detect a density change
second line of defense
Supply / Communication PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM
Ambient temperature -50 °C...+70 °C
(-58 °F...+158 °F)
Process temperature -60 °C...+280 °C
(-76 °F...+540 °F)
(300°C / 572°F, 50h cumulated)
Process pressure / max. overpressure limit Vacuum...100 bar
(Vacuum...1450 bar)
Min. density of medium 0.5g/cm³ (0.4g/cm³ optional)
Main wetted parts 316L / Alloy
PFA and Enamel on request
Process connection Thread:
G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
Flange:
DIN DN25...DN100,
ASME 1"...4",
JIS 25A...100A
Sensor length Length 130mm (5.12") (Liquiphant II)
148mm...3000mm / 6000mm optional
(5.83"...118" / 236" optional)
Communication PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000
Marine approval GL/ ABS
Options Heavy duty stainless steel housing mainly for the oil and gas industry
Components FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR

The Liquiphant FTL71 vibronic point level switch can be used in hazardous areas and has various international approvals. The FTL71 is especially suitable for high-temperature applications up to 280 °C, with functional safety up to SIL2 and up to SIL3 with homogeneous redundancy. The second line of defense ensures the highest degree of device safety and availability. The measured value is stable and unaffected by flow, turbulence, bubbles, foam, vibration, solids content or buildup.

 

Benefits

Suitable for safety systems requiring SIL2/SIL3 functional safety, in accordance with IEC 61508/IEC 61511-1

Welded, hermetically sealed feedthrough ensures maximum safety even if the sensor is damaged

Various electronic inserts, such as NAMUR, relay, semiconductor thyristor, PFM signal output, for connection to various process control systems

Various process connections available

No calibration required: fast and economical device startup

No mechanical moving parts, no maintenance, no wear and a long service life. The fork can be monitored for damage to ensure proper function

FDA-listed material (PFA Edlon)

 

Application areas

Limit switch for detection of all types of liquids.

Process connection: thread and flange

Temperature: -60 ~ +280 °C (-76 ~ +540 °F)

Pressure: -1 ~ +100 bar (-14.5 ~ +1,450 psi)

Sensor material: 316L, Alloy (PFA and enamel optionally available)

International explosion protection approval, WHG overflow protection, SIL, marine approval

 

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

市政污水处理

市政污水处理污水处理厂 · 音叉应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 音叉应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 音叉应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 音叉应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。