Configurable Models 1 models
The process transmitter Nivotester FTR525 is used in conjunction with the microwave barrier Soliwave FQR57/FDR57 for detection of point levels and bulk flow (flow / no flow, trend). The microwave barrier is also suitable for detecting and counting objects, detection of deposits as well as monitoring of filling processes and material transfer points. It can be installed in containers, conduits, hoppers, filling stations, shafts, filters or on free fall shafts.
Compare

Point Level / Solids

Measuring Principle Microwave barrier
Characteristic / Application Process transmitter for FQR57 / FDR57
With graphical display
Many settings like:
:: Sensitivity, attenuation, channel
:: Switch on and off points, delay
Functions for application analysis
Design: Top-hat rail
Supply / Communication 24-230 VDC (-15%/+10%)
resp. 42-230 VAC (-15%/+10%),
50/60Hz
Ambient temperature -20 °C...+60 °C
(-4 °F...+140 °F)
Communication Relay, SPDT
Solid-state relay
4-20 mA
Alarm open collector
Certificates / Approvals ATEX, CSA C/US, IEC Ex
Components Transmitter: FQR57
Transceiver: FDR57

The Nivotester FTR525 process transmitter is used together with the Soliwave FQR57/FDR57 microwave barrier for limit detection and bulk solids flow detection (non-zero flow/zero flow, flow trend). The microwave barrier can be used for detection and counting, detection of deposits, and monitoring of the feeding process and material transport quantity. It can be installed in vessels, channels, on stockpiles, at feed stations, in pumping stations, in filters or in other free-fall shafts.

Advantages
Simple, convenient menu-guided operation via the display unit and operating keys
Various adjustment functions (automatic or manual operation), clear graphic display of the set detection range and current signal strength
Up to 5 different channels can be set to operate several microwave barriers installed side by side simultaneously
Application analysis functions available
Various adjustment functions such as damping time, selectable switch-on and switch-off points, and switch-on/switch-off delay times
Compact housing for easy installation, conveniently mounted in-line on a standard top-hat rail and wired via pluggable terminal blocks
Online monitoring including the sensors ensures high operational safety

Application
Non-contact (wear-free, maintenance-free) limit detection (low/high limit) and flow monitoring (non-zero flow/zero flow, flow trend) of bulk solids.
Provides detection, counting and positioning functions
Detects and analyzes deposits and contaminants in filters
Monitors the feeding process
Monitors the material transport quantity
Suitable for use at maximum temperatures not exceeding 450°C (+842°F)
Suitable for use at maximum pressures not exceeding 20 bar (+290 psi)
International explosion protection certification

 

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Model Name
FTR525-AA22+AB 过程变送器 适用FQR57/FDR57
市政污水处理

市政污水处理污水处理厂 · 微波限位应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对微波限位的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的微波限位,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 微波限位应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对微波限位的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的微波限位,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 微波限位应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对微波限位的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的微波限位,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 微波限位应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对微波限位的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的微波限位,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。