Technical Data
CompareContinuous / Liquids
| Measuring Principle | Ultrasonic |
| Characteristic / Application | Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter |
| Supply / Communication | 4-wire (HART, PROFIBUS DP) |
| Accuracy | +/- 2 mm + 0.17% of measured distance |
| Ambient temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
| Process temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
| Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 43 psi) |
| Main wetted parts | UP (unsaturated polyester) |
| Process connection | G / NPT 1" |
| Blocking distance | 0.6 m (2 ft) |
| Max. measurement distance | Liquids: 25 m (85 ft), Solids: 15 m (50 ft) |
| Communication | Transmitter: 4...20 mA HART PROFIBUS DP |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex |
| Options | Second 4...20 mA output |
| Components | Transmitter: FMU90, FMU95 |
| Application limits | For tank farms scanner: FMU95 |
Continuous / Solids
| Measuring Principle | Ultrasonic |
| Characteristic / Application | Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter |
| Supply / Communication | 4-wire (HART, PROFIBUS DP) |
| Accuracy | +/- 2mm + 0.17% of measured distance |
| Ambient temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
| Process temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
| Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 43 psi) |
| Main wetted parts | UP (unsaturated polyester) |
| Process connection | G / NPT 1" |
| Blocking distance | 0.6 m (2 ft) |
| Max. measurement distance | Liquids: 25 m (85 ft), Solids: 15 m (50 ft) |
| Communication | Transmitter: 4 ... 20 mA HART PROFIBUS DP |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex |
| Options | Second 4...20mA output |
| Components | Transmitter: FMU90 |
The FDU93 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids, is maintenance-free, and can also be used for flow measurement in open channels and weirs. The measured values are unaffected by dielectric constant, density or humidity, and the self-cleaning function of the sensor eliminates the influence of medium adhesion on the measurement. Suitable for hazardous areas; maximum measuring range: liquids 25 m (85 ft), solids 15 m (50 ft).
Benefits
Integrated temperature sensor for time-of-flight correction. Precise measurement even when the temperature changes
Suitable for use in harsh climatic conditions; sensor and transmitter can be installed separately up to 300 m apart
Sensor self-cleaning function reduces adhesion formation
Integrated automatic sensor detection for convenient commissioning with the FMU90 / FMU95 level transmitter
Degree of protection IP68
Non-contact measurement minimizes service requirements
Dust-Ex and gas-Ex approval (ATEX, FM, CSA)
Applications
Suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids; flow measurement in open channels and weirs. Maximum measuring range: liquids 25 m, solids 15 m; suitable for hazardous areas; other measuring ranges: FDU91/91F: liquids 10 m, solids 5 m; FDU92: liquids 20 m, solids 10 m; FDU95: solids 45 m; FDU96: solids 70 m
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measurement principle video
Source: Endress+Hauserpublic information from the website
Related Models
| Model | Name |
|---|---|
| FDU93-AG1A | 超声波液位计探头 |
| FDU93-AG2A | 超声波液位计探头 |
| FDU93-AG3A | 超声波液位计探头 |
| FDU93-AG4A | 超声波液位计探头 |
| FDU93-AG5A | 超声波液位计探头 |
| FDU93-AG6A | 超声波液位计探头 |
| FDU93-AN1A | 超声波液位计探头 |
| FDU93-AN2A | 超声波液位计探头 |
| FDU93-AN3A | 超声波液位计探头 |
| FDU93-AN4A | 超声波液位计探头 |
| FDU93-AN5A | 超声波液位计探头 |
| FDU93-AN6A | 超声波液位计探头 |
| FDU93-JG1A | 超声波液位计探头 |
| FDU93-JG2A | 超声波液位计探头 |
| FDU93-JG3A | 超声波液位计探头 |
| FDU93-JG4A | 超声波液位计探头 |
| FDU93-JG5A | 超声波液位计探头 |
| FDU93-JG6A | 超声波液位计探头 |
| FDU93-JN1A | 超声波液位计探头 |
| FDU93-JN2A | 超声波液位计探头 |
| FDU93-JN3A | 超声波液位计探头 |
| FDU93-JN4A | 超声波液位计探头 |
| FDU93-JN5A | 超声波液位计探头 |
| FDU93-JN6A | 超声波液位计探头 |
| FDU93-LG1A | 超声波液位计探头 |
| FDU93-LG2A | 超声波液位计探头 |
| FDU93-LG3A | 超声波液位计探头 |
| FDU93-LG4A | 超声波液位计探头 |
| FDU93-LG5A | 超声波液位计探头 |
| FDU93-LG6A | 超声波液位计探头 |
| FDU93-LN1A | 超声波液位计探头 |
| FDU93-LN2A | 超声波液位计探头 |
| FDU93-LN3A | 超声波液位计探头 |
| FDU93-LN4A | 超声波液位计探头 |
| FDU93-LN5A | 超声波液位计探头 |
| FDU93-LN6A | 超声波液位计探头 |
| FDU93-RG1A | 超声波液位计探头 |
| FDU93-RG2A | 超声波液位计探头 |
| FDU93-RG3A | 超声波液位计探头 |
| FDU93-RG4A | 超声波液位计探头 |
| FDU93-RG5A | 超声波液位计探头 |
| FDU93-RG6A | 超声波液位计探头 |
| FDU93-RN1A | 超声波液位计探头 |
| FDU93-RN2A | 超声波液位计探头 |
| FDU93-RN3A | 超声波液位计探头 |
| FDU93-RN4A | 超声波液位计探头 |
| FDU93-RN5A | 超声波液位计探头 |
| FDU93-RN6A | 超声波液位计探头 |
Case Studies
市政污水处理污水处理厂 · 超声波应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对超声波的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 超声波应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对超声波的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 超声波应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对超声波的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 超声波应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对超声波的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。