Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CPF82E

 CPF82E

ORP电极

Configurable Models 1 models
ORP electrode CPF82E has a compact structure and is suitable for industries such as wastewater, metallurgy, mining, and basic raw materials
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Flotation, leaching, neutralization, outlet monitoring
Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4"
Measuring range -1500mV to +1500mV
Measuring principle Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum ring
Design Compact electrode in PPS housing with NPT3/4" process connection
Material Housing: PPS
ORP electrode: platinum ring
Double chamber reference system: KNO3 and KCl/AgCl
Dimension Diameter: 22 mm (0.87 inch)
Length: 150 mm (5.91 inch)
Process temperature 0 to 80 °C (32 to 170 °F)
Process pressure 1 to 10 bar abs at 80 °C
(15 to 145 psi abs at 176 °F)
Temperature sensor NTC
Ex certification (optional) FM IS NI Cl. I Div.1&2, Groups A-D
Connection Process connection: NPT 3/4"
Memosens plug
Ingress protection IP 68

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Flotation, leaching, neutralization, outlet monitoring
Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4"
Measuring range -1500mV to +1500mV
Measuring principle Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum ring
Design Compact electrode in PPS housing with NPT3/4" process connection
Material Housing: PPS
ORP electrode: platinum ring
Double chamber reference system: KNO3 and KCl/AgCl
Dimension Diameter: 22 mm (0.87 inch)
Length: 150 mm (5.91 inch)
Process temperature 0 to 80 °C (32 to 170 °F)
Process pressure 1 to 10 bar abs at 80 °C
(15 to 145 psi abs at 176 °F)
Temperature sensor NTC
Ex certification (optional) FM IS NI Cl. I Div.1&2, Groups A-D
Connection Process connection: NPT 3/4"
Memosens plug
Ingress protection IP 68
Model Name
CPF82E-AA5PAD1 ORP电极
市政污水处理

市政污水处理污水处理厂 · ORP应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对ORP的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · ORP应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对ORP的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · ORP应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对ORP的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · ORP应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对ORP的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。