Technical Data
CompareDisinfection
| Measuring Principle | Total chlorine |
| Application | Wastewater treatment plants, disinfection monitoring and control in wastewater outlet, reuse of outlet water, utilities of all industries, all disinfection measuring points |
| Characteristic | Amperometric measurement of total chlorine |
| Measuring range | 0.1 to 10 mg/l total chlorine |
| Measuring method | Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent |
| Design | Closed, membrane covered measuring cell |
| Material | Sensor shaft: PVC Membrane: PET Membrane cap: PPE |
| Dimension | Diameter: 25 mm (0.98 inch) Length: 148 mm (5.83 inch) |
| Process temperature | 5 to 45 °C (41 to 113 °F) |
| Process pressure | 1 to 4 bar (14.5 to 58 psi) |
| Temperature sensor | 10k NTC integrated (Memosens) |
| Connection | Inductive, digital connection head with Memosens |
Total chlorine is the collective term for free chlorine and combined chlorine, and is also an indicator of the residual disinfectant concentration in discharged water. The CCS120D reliably monitors the total chlorine limit at the outlet. The convenient replacement of the electrolyte and membrane cap significantly reduces maintenance costs. The CCS120D uses Memosens digital technology with maximum process safety and data integrity. The sensor is moisture- and corrosion-resistant and can be calibrated in the laboratory for predictive maintenance.
Benefits
Simple operation thanks to Memosens digital technology
Storage of sensor and process parameters enables predictive maintenance
Fast replacement of membrane cap and electrolyte, low maintenance workload
Flexible installation in the CYA112 immersion holder or the CCA250 flow-through holder
Used together with the Liquiline multichannel transmitter, other relevant water quality parameters can be measured simultaneously.
Applications
The Memosens CCS120D is used for total chlorine measurement:
Wastewater treatment plants
- Disinfectant monitoring and control at the wastewater outlet
- Outlet water recycling and reuse
Utilities in all industries
- All disinfection measuring points
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
Source: Endress+Hauserpublic information from the website
Case Studies
市政污水处理污水处理厂 · 消毒应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对消毒的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 消毒应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对消毒的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 消毒应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对消毒的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 消毒应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对消毒的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。