Technical Data
CompareContinuous / Liquids
| Measuring Principle | Differential pressure |
| Characteristic / Application | Transmitter with metal membrane for differential pressure monitoring in liquids or gases. Intuitive and clear wizard for commissioning |
| Specialities | Bluetooth® Operation and maintenance with SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
| Supply / Communication | Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC |
| Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
| Long term stability | 0.05 % of URL/ year 0.13 % of URL/ 5 years 0.23 % of URL/ 10 years |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Process temperature | -40°C...+110°C (-40°F...+230°F) |
| Process pressure / max. overpressure limit | 250 bar (3750 psi) |
| Pressure measuring range | 10 mbar.... 40 bar (0.15 psi... 600 psi) |
| Main wetted parts | 316L, AlloyC |
| Process connection | NPT 1/4-18, RC1/4" |
| Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN 10204-3.1, NACE MR0175, NACE MR0103, AD2000 |
| Drinking water approvals | NSF, KTW |
| Application limits | None |
Gas
| Measuring Principle | Differential pressure |
| Product headline | Smart transmitter with metal membrane for differential pressure monitoring. Accurate differential pressure-, level- or flow measurement in liquids or gases. |
| Sensor features | Fill fluid: Inert oil, Silicone oil |
| Transmitter features | Bluetooth® Operation and maintenance Smartblue App, RFID TAG for easy identification, Plug and play functionalities |
| Wetted materials | 316L, Alloy |
| Measuring range | 10 mbar...40 bar (0.15 psi...600 psi) |
| Medium temperature range | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature range | -40°C...+85°C (-40°F...+185°F) |
| Transmitter housing material | Aluminium |
| Display/Operation | Configuration via local display and operating tools possible Remote display available |
| Outputs | 4...20 mA HART |
| Digital communication | HART |
| Hazardous area approvals | ATEX, CSA, IECEx |
| Functional safety | SIL |
| Material certificates | EN10204-3.1, NACE MR0175, NACE MR0103 AD2000 |
Liquids
| Measuring Principle | Differential pressure |
| Product headline | Smart transmitter with metal membrane for differential pressure monitoring. Accurate differential pressure-, level- or flow measurement in liquids or gases. |
| Sensor features | Fill fluid: Inert oil, Silicone oil |
| Transmitter features | Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
| Wetted materials | 316L, Alloy |
| Measuring range | 10 mbar...40 bar (0.15 psi...600 psi) |
| Medium temperature range | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature range | -40°C...+85°C (-40°F...+185°F) |
| Transmitter housing material | Aluminium |
| Display/Operation | Configuration via local display and operating tools possible Remote display available |
| Outputs | 4...20 mA HART |
| Digital communication | HART |
| Hazardous area approvals | ATEX, CSA, IECEx |
| Functional safety | SIL |
| Material certificates | EN10204-3.1, NACE MR0175, NACE MR0103 |
Pressure
| Measuring Principle | Differential pressure |
| Characteristic | Transmitter with metal membrane for differential pressure monitoring in liquids or gases. Intuitive and clear wizard for commissioning |
| Supply voltage | Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC |
| Reference Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
| Long term stability | 0.05 % of URL/ year 0.13 % of URL/ 5 years 0.23 % of URL/ 10 years |
| Process temperature | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Measuring cell | 10 mbar.... 40 bar (0.15 psi... 600 psi) |
| Smallest calibratable span | 0.25 mbar (0.00375 psi) |
| Vacuum resistance | 25 mbar (0.0375 psi) |
| Max. Turn down | 100:1 |
| Max. overpressure limit | 375 bar (5625 psi) |
| Process connection | NPT 1/4-18, RC1/4" |
| Material process membrane | 316L, AlloyC, Gold |
| Material gasket | EPDM, HNBR, FVMQ, |
| Fill fluid | Silicone oil, Inert oil |
| Material housing | Aluminium |
| Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN 10204-3.1, NACE MR0175, NACE MR0103, AD2000 |
| Drinking water approvals | NSF, KTW |
| Specialities | Bluetooth® Operation and maintenance with SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
PMD55B is a member of the new generation of Deltabar transmitters. The transmitter is robust and supports both on-site and remote operation. The transmitter can be controlled remotely via an app using a mobile device and a secure Bluetooth connection. PMD55B supports on-demand maintenance and significantly improves service efficiency.
The software is equally easy to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests, minimizing the risk of operating errors.
Benefits
Wireless remote control of devices within the production area using the SmartBlue App, without interrupting the process
Fewer on-site incidents, protecting devices installed at hard-to-reach measuring points
Reduced risk of system failure, error-free SIL commissioning and guided functional safety testing of the instrument
Applications
Maximum working pressure 40 bar (600 psi)
Maximum working static pressure 250 bar (3750 psi)
Highest measurement accuracy of +/-0.055%
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Related Models
Case Studies
市政污水处理污水处理厂 · 差压测量应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对差压测量的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 差压测量应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对差压测量的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 差压测量应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对差压测量的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 差压测量应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对差压测量的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。