Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CLS16B Analog conductivity sensor

CLS16B  Analog conductivity sensor

模拟电导率传感器

Configurable Models 90 models
Contacting conductivity sensor for hygienic applications in the food & beverage and life sciences industries
Compare

Conductivity

Measuring Principle Conductive
Application Pharmaceuticals, pure and ultrapure water
Characteristic Hygienic 2-electrode conductivity sensor
Measuring range k=0,1: 0,04µS/cm - 500µS/cm
Measuring principle Conductive conductivity cell
Design Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished stainless steel and FDA sealing material; sterilizable
Material In contact with medium
Sensor depending on order execution:
Electropolished, stainless steel 1.4435 (AISI 316L)
PEEK
Sealing depending on order execution:
Form seal ISOLAST (FFKM)
Form seal EPDM
Dimension Electrode diameter: 17 mm
(0.66 inch)
Electrode length: 54 mm
( 2.10 inch)
Process temperature Max. 120°C (150°C/30 min)
max. 248°F (302°F/30 min.)
Process pressure max. 12 bar at 20°C
max.174 psi at 68°F
Temperature sensor Integrated Pt100 or Pt1000
Ex certification ATEX
Connection Process connection: Varivent, Neumo, Clamp
Cable: TOP68 connector or fixed cable
Ingress protection IP68
Certificates, declarations and approvals Inspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,38 µm)
Conformity to cGMP derived requirements
ASME BPE
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I

Field of application
Condumax CLS16B is an analog sensor for precise measurement in the low conductivity range of pure and ultrapure water. Its certified hygienic design complies with the relevant standards EHEDG, USP Class VI and ASME-BPE. Various hygienic process connections ensure the perfect fit for your process.
Condumax CLS16B measures conductivity in pure and ultrapure water for the monitoring of:
Ion exchangers
Reverse osmosis
Distillation
Water for injection (WFI)
With its international explosion protection approvals, such as ATEX, FM, CSA and NEPSI, the analog sensor is suitable for hazardous area use.

Benefits
Perfectly suited to life sciences and food & beverage: Complies with EHEDG, ASME, FDA and USP Class VI
Hygienic: Autoclavable, sterilizable and suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
Accurate: Cell constant of the sensor is measured individually
Robust: Electropolished stainless steel body for corrosion-free operation and easy cleaning
Long-operating life: Replaceable, hygienic EPDM/PEEK sealing

 

Conductive:

Measuring Principle Conductive
Application Pharmaceuticals, pure and ultrapure water
Characteristic Hygienic 2-electrode conductivity sensor
Measuring range k=0,1: 0,04µS/cm - 500µS/cm
Measuring principle Conductive conductivity cell
Design Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished stainless steel and FDA sealing material; sterilizable
Material In contact with medium
Sensor depending on order execution:
Electropolished, stainless steel 1.4435 (AISI 316L)
PEEK
Sealing depending on order execution:
Form seal ISOLAST (FFKM)
Form seal EPDM
Dimension Electrode diameter: 17 mm
(0.66 inch)
Electrode length: 54 mm
( 2.10 inch)
Process temperature Max. 120°C (150°C/30 min)
max. 248°F (302°F/30 min.)
Process pressure max. 12 bar at 20°C
max.174 psi at 68°F
Temperature sensor Integrated Pt100 or Pt1000
Ex certification ATEX
Connection Process connection: Varivent, Neumo, Clamp
Cable: TOP68 connector or fixed cable
Ingress protection IP68
Additional certifications - calibration certification - surface roughness Ra<0,8 (0,4)- Material certification 3.1.B - EHEDG, pharma certificate of compliance
Model Name
CLS16B-AACA401A 模拟电导率传感器
CLS16B-AACA401B 模拟电导率传感器
CLS16B-AACA402A 模拟电导率传感器
CLS16B-AACA402B 模拟电导率传感器
CLS16B-AACA403A 模拟电导率传感器
CLS16B-AACA403B 模拟电导率传感器
CLS16B-AACB401A 模拟电导率传感器
CLS16B-AACB401B 模拟电导率传感器
CLS16B-AACB402A 模拟电导率传感器
CLS16B-AACB402B 模拟电导率传感器
CLS16B-AACB403A 模拟电导率传感器
CLS16B-AACB403B 模拟电导率传感器
CLS16B-AACC401A 模拟电导率传感器
CLS16B-AACC401B 模拟电导率传感器
CLS16B-AACC402A 模拟电导率传感器
CLS16B-AACC402B 模拟电导率传感器
CLS16B-AACC403A 模拟电导率传感器
CLS16B-AACC403B 模拟电导率传感器
CLS16B-AAEH401A 模拟电导率传感器
CLS16B-AAEH401B 模拟电导率传感器
CLS16B-AAEH402A 模拟电导率传感器
CLS16B-AAEH402B 模拟电导率传感器
CLS16B-AAEH403A 模拟电导率传感器
CLS16B-AAEH403B 模拟电导率传感器
CLS16B-AAVA401A 模拟电导率传感器
CLS16B-AAVA401B 模拟电导率传感器
CLS16B-AAVA402A 模拟电导率传感器
CLS16B-AAVA402B 模拟电导率传感器
CLS16B-AAVA403A 模拟电导率传感器
CLS16B-AAVA403B 模拟电导率传感器
CLS16B-BACA401A 模拟电导率传感器
CLS16B-BACA401B 模拟电导率传感器
CLS16B-BACA402A 模拟电导率传感器
CLS16B-BACA402B 模拟电导率传感器
CLS16B-BACA403A 模拟电导率传感器
CLS16B-BACA403B 模拟电导率传感器
CLS16B-BACB401A 模拟电导率传感器
CLS16B-BACB401B 模拟电导率传感器
CLS16B-BACB402A 模拟电导率传感器
CLS16B-BACB402B 模拟电导率传感器
CLS16B-BACB403A 模拟电导率传感器
CLS16B-BACB403B 模拟电导率传感器
CLS16B-BACC401A 模拟电导率传感器
CLS16B-BACC401B 模拟电导率传感器
CLS16B-BACC402A 模拟电导率传感器
CLS16B-BACC402B 模拟电导率传感器
CLS16B-BACC403A 模拟电导率传感器
CLS16B-BACC403B 模拟电导率传感器
CLS16B-BAEH401A 模拟电导率传感器
CLS16B-BAEH401B 模拟电导率传感器
CLS16B-BAEH402A 模拟电导率传感器
CLS16B-BAEH402B 模拟电导率传感器
CLS16B-BAEH403A 模拟电导率传感器
CLS16B-BAEH403B 模拟电导率传感器
CLS16B-BAVA401A 模拟电导率传感器
CLS16B-BAVA401B 模拟电导率传感器
CLS16B-BAVA402A 模拟电导率传感器
CLS16B-BAVA402B 模拟电导率传感器
CLS16B-BAVA403A 模拟电导率传感器
CLS16B-BAVA403B 模拟电导率传感器
CLS16B-NACA401A 模拟电导率传感器
CLS16B-NACA401B 模拟电导率传感器
CLS16B-NACA402A 模拟电导率传感器
CLS16B-NACA402B 模拟电导率传感器
CLS16B-NACA403A 模拟电导率传感器
CLS16B-NACA403B 模拟电导率传感器
CLS16B-NACB401A 模拟电导率传感器
CLS16B-NACB401B 模拟电导率传感器
CLS16B-NACB402A 模拟电导率传感器
CLS16B-NACB402B 模拟电导率传感器
CLS16B-NACB403A 模拟电导率传感器
CLS16B-NACB403B 模拟电导率传感器
CLS16B-NACC401A 模拟电导率传感器
CLS16B-NACC401B 模拟电导率传感器
CLS16B-NACC402A 模拟电导率传感器
CLS16B-NACC402B 模拟电导率传感器
CLS16B-NACC403A 模拟电导率传感器
CLS16B-NACC403B 模拟电导率传感器
CLS16B-NAEH401A 模拟电导率传感器
CLS16B-NAEH401B 模拟电导率传感器
CLS16B-NAEH402A 模拟电导率传感器
CLS16B-NAEH402B 模拟电导率传感器
CLS16B-NAEH403A 模拟电导率传感器
CLS16B-NAEH403B 模拟电导率传感器
CLS16B-NAVA401A 模拟电导率传感器
CLS16B-NAVA401B 模拟电导率传感器
CLS16B-NAVA402A 模拟电导率传感器
CLS16B-NAVA402B 模拟电导率传感器
CLS16B-NAVA403A 模拟电导率传感器
CLS16B-NAVA403B 模拟电导率传感器
市政污水处理

市政污水处理污水处理厂 · 电导率应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导率应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导率应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导率应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。