Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CPA871 手动或自动可伸缩式安装支架

CPA871  手动或自动可伸缩式安装支架

手动或自动可伸缩式安装支架

Cleanfit CPA871 guarantees the highest operational safety in both standard and demanding applications. Its intelligent functions prevent any leakage of medium during operation, cleaning or calibration, offering optimum protection of the process and operating personnel. The retractable assembly flexibly adapts to your application. Be it long immersion depths in sticky media, aggressive environments or hazardous areas, you choose the right material and specification to suit your application.
Compare

Conductivity

Measuring Principle Sensor ORP / Redox
Application Water and wastewater including sea water, chemical industry, oil and gas, electricity and energy, hazardous areas, mining, minerals & metals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Robust and safe style
Manual or pneumatic
Material Seals: EPDM, FPM (Viton) or FFKM
Immersion tube, process connection, service chamber: Stainless steel 1.4404 Ra < 0.76, PEEK,
Alloy C22 Ra <0.76, PVDF, conductive PVDF
Dimension Immersion depth: 32.2 to 188.6 mm (1.27 to 7.40 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F) for all materials except PVDF and conductive PVDF
-10 to 100 / 90 °C (14 to 212 / 194 °F) for PVDF and conductive PVDF materials
Process pressure Stainless steel, Alloy C22, PEEK:
16 bar up to 140 °C (232 psi up to 284 °F)
PVDF, conductive PVDF:
Basic version: 16 bar up to 100 °C (232 psi up to 212 °F)
Immersion chamber version:
4 bar to 90 °C (58 psi up to 194 °F)
Connection Clamp 2", ISO2852, ASME BPE-2012, Clamp 2½", Flange DN 40, DN50, DIN65, DN80, EN1092-1, ASME B16.5, 10K50, JIS B2220, 10K80, Thread NPT 1½", Thread ISO 228 G1¼

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Water and wastewater including sea water, chemical industry, oil and gas, electricity and energy, hazardous areas, mining, minerals & metals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Robust and safe style
Manual or pneumatic
Material Seals: EPDM, FPM (Viton) or FFKM
Immersion tube, process connection, service chamber: Stainless steel 1.4404 Ra < 0.76, PEEK,
Alloy C22 Ra <0.76, PVDF, conductive PVDF
Dimension Immersion depth: 32.2 to 188.6 mm (1.27 to 7.40 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F) for all materials except PVDF and conductive PVDF
-10 to 100 / 90 °C (14 to 212 / 194 °F) for PVDF and conductive PVDF materials
Process pressure Stainless steel, Alloy C22, PEEK:
16 bar up to 140 °C (232 psi up to 284 °F)
PVDF, conductive PVDF:
Basic version: 16 bar up to 100 °C (232 psi up to 212 °F)
Immersion chamber version:
4 bar to 90 °C (58 psi up to 194 °F)
Connection Clamp 2", ISO2852, ASME BPE-2012, Clamp 2½", Flange DN 40, DN50, DIN65, DN80, EN1092-1, ASME B16.5, 10K50, JIS B2220, 10K80, Thread NPT 1½", Thread ISO 228 G1¼

pH

Measuring Principle Potentiometric
Application Water and wastewater including sea water, chemical industry, oil and gas, electricity and energy, hazardous areas, primaries and metals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Robust and safe style
Manual or pneumatic
Material Seals: EPDM, FPM (Viton) or FFKM
Immersion tube, process connection, service chamber: Stainless steel 1.4404 Ra < 0.76, PEEK,
Alloy C22 Ra <0.76, PVDF, conductive PVDF
Dimension Immersion depth: 32.2 to 188.6 mm (1.27 to 7.40 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F) for all materials except PVDF and conductive PVDF
-10 to 100 / 90 °C (14 to 212 / 194 °F) for PVDF and conductive PVDF materials
Process pressure Stainless steel, Alloy C22, PEEK:
16 bar up to 140 °C (232 psi up to 284 °F)
PVDF, conductive PVDF:
Basic version: 16 bar up to 100 °C (232 psi up to 212 °F)
Immersion chamber version:
4 bar to 90 °C (58 psi up to 194 °F)
Connection Clamp 2", ISO2852, ASME BPE-2012, Clamp 2½", Flange DN 40, DN50, DIN65, DN80, EN1092-1, ASME B16.5, 10K50, JIS B2220, 10K80, Thread NPT 1½", Thread ISO 228 G1¼

The Cleanfit CPA871 ensures maximum operating safety in standard and demanding applications. Its intelligent functions prevent any medium leakage during operation, cleaning or calibration, providing optimal protection for the process and operating personnel. The retractable assembly flexibly adapts to your application conditions. With long insertion depths in viscous media, corrosive environments or hazardous areas, selecting the right material and specifications ensures your application requirements are met.

 

Benefits

Maximum operating safety: intelligent functions prevent the assembly from being moved into the process without a sensor and prevent the sensor from being removed at the measuring position.

Suitable for demanding applications: optional immersion chamber eliminates problems caused by viscous media.

Rugged assembly design: steel base housing ensures mechanical stability.

Flexible adaptation to process conditions: wide range of process connections and wetted-part materials, even for corrosive media or hazardous areas.

 

Application areas

The Cleanfit CPA871 is a retractable assembly for installing pH electrodes, ORP electrodes, dissolved oxygen sensors and NIR sensors with a diameter of 12 mm and lengths of 120/225/360 mm.

 

Its design offers the highest safety in the following industries:

 

Water and wastewater industry (including seawater applications)

Chemical industry

Oil and gas industry

Power and energy industry

Hazardous areas

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

市政污水处理

市政污水处理污水处理厂 · 支架应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 支架应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 支架应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 支架应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。