Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

6TAB 热式质量流量计

6TAB  热式质量流量计

热式质量流量计

The t-mass T 150 is the first thermal mass device from Endress+Hauser for measuring liquids. t-mass T 150 is designed chiefly for water applications. As it measures independently of the electrical conductivity of a fluid and can be used in a variety of water-based and non-water-based liquids for the purpose of monitoring and trending. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Compare

Liquids

Measuring Principle Thermal
Product headline The flowmeter for reliable and easy monitoring of liquids. Dedicated to the
monitoring of conductive and non‐conductive liquids.
Sensor features High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1½ to 40"). Sensor in standard or hygienic version.
Transmitter features Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output.
Nominal diameter range DN 40 to 1000 (1½ to 40")
Wetted materials Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)
Measured variables Mass flow, temperature, volume flow
Max. measurement error Flow: ±5 % o.f.s.
Measuring range 226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)
Max. process pressure PN 40
Medium temperature range –20 to +100 °C (–4 to +212 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
Power supply DC 18 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, EAC
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Hygienic approvals: EHEDG, 3-A
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates Sanitary approval: 3-A, EHEDG

The t-mass T 150 is the first Endress+Hauser thermal mass flowmeter for liquid measurement. The t-mass T 150 is mainly used for measurement in water; when the flowmeter measures the conductivity of a liquid independently, it can also be used for monitoring and trend monitoring of various conductive and non-conductive liquids. User-specific substances can be stored on the display and transferred from one device to another via the display.

 

Advantages

Specially designed for monitoring conductive and non-conductive liquids

High process safety: built-in temperature compensation, high repeatability and linearity

Economical measurement: easy installation, negligible pressure loss, maintenance-free

Reliable flow trend: multivariable measurement

Fast and effective commissioning: guided operating menu

High plant adaptability: self-diagnostics and error monitoring

Automatic data recovery for easy maintenance

 

Areas of application

The measuring principle has a highly operable measuring range and directly measures mass flow

Professional measurement of conductive and non-conductive liquid flow

Device features

 

Insertion type suitable for pipes with nominal diameters from DN 40 to 1000 (1 1/2 to 40")

Standard sensor or hygienic sensor

SIP-resistant, temperature up to 130 °C (266 °F)

Compact version with DC 24 V power supply

4-20 mA HART, pulse/frequency/switch output

Compact and robust transmitter

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 热式气体质量流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热式气体质量流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热式气体质量流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热式气体质量流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。