Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Conductive |
| Characteristic / Application | One rod probe for high temperature and high pressure. corrosion resistant |
| Supply / Communication | Relay |
| Ambient temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
| Process temperature | -40 °C ... 135 °C (-40 °F ... 275 °F) |
| Process pressure / max. overpressure limit | Vacuum ... 50 bar (Vacuum ... 725 psi) |
| Min. conductivity of medium | 20 µS/cm |
| Main wetted parts | PTFE, 316TI |
| Process connection | G1/2 |
| Sensor length | 0.05m ... 2m (2" ... 79") |
| Communication | Relay |
| Certificates / Approvals | ATEX |
| Components | Transmitter: FTW325 |
| Application limits | observe min. medium conductivity |
The economical 11375Z probe can be used for limit detection of various liquids in processes and tanks.
Advantages
A cooler can be fitted when measuring high-temperature liquids (e.g. 100°C)
Probe length can be shortened
WHG (German Water Resources Act) + ATEX II 1/2 G approval
Can be connected to the independent FTW325 switching unit
Linear monitoring, safe and reliable
No moving parts in the tank, no wear, long service life, reliable function
Economical probe for conductive liquids
Areas of application
For limit detection of various liquids in processes or tanks:
Conductivity of 0.02mS/cm
Temperature range 40~+200°C
Pressure up to 50bar; linear monitoring and overflow protection in explosion Zone 0, upper/lower limit detection in tanks, protection of pipeline pumps, and two-point control
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
市政污水处理污水处理厂 · 电导式应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电导式应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电导式应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电导式应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。