The FDU92 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 20m (65ft), solids 10m (33ft).
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA 6P)
Process connection G / NPT 1"
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20 mA output
Components Transmitter:
FMU90, FMU95
Application limits For tank farms scanner:
FMU95

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA 6P)
Process connection G / NPT 1"
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20mA output
Components Transmitter:
FMU90

Liquids

Measuring Principle Ultrasonic
Product headline Ultrasonic sensor for level and open channel flow measurement.
For applications requiring separate level / open channel flow measurement system.
Max. measurement error accuracy:
distance measurement: +/- 2mm + 0.17%
Measuring range Up to 20m / 65ft
Max. process pressure 0.4 bar...4 bar
(10 psi...58 psi)
Medium temperature range -40...95°C
(-40...203°F)
Degree of protection IP68
Display/Operation Transmitter FMU90
Outputs Transmitter:
4...20mA HART
PROFIBUS DP
Inputs Transmitter FMU90
Digital communication HART, PROFIBUS DP
Hazardous area approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

The FDU92 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids, is maintenance-free and can also be used for flow measurement in open channels and measuring weirs. Measured values are unaffected by dielectric constant, density or humidity, and the sensor self-cleaning function eliminates the influence of medium adhesion on measurement. Suitable for explosive hazardous areas; maximum measuring range: liquids 20m (65ft), solids 10m (33ft).

 

Advantages

Built-in temperature sensor for time-of-flight calibration; precise measurement even with temperature changes

Hermetically welded PVDF sensor for the highest level of corrosion-resistant measurement applications

Suitable for harsh climatic conditions; sensor and transmitter can be installed separately with a maximum distance of 300m

Sensor self-cleaning function reduces adhesion formation

Built-in automatic sensor detection for convenient commissioning with the FMU90/FMU95 level transmitter

Degree of protection IP68

Dust-Ex and gas-Ex approvals (ATEX, FM, CSA)

 

Areas of application

Suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids; flow measurement in open channels and measuring weirs. Maximum measuring range: liquids 20m, solids 10m; suitable for explosive hazardous areas; other measuring ranges: FDU91/91F: liquids 10m, solids 5m; FDU93: liquids 25m, solids 15m; FDU95: solids 45m; FDU96: solids 70m

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

 

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source:Endress+Hauserwebsite public information

Model Name
FDU92-AG1A 超声波液位计探头
FDU92-AG2A 超声波液位计探头
FDU92-AG3A 超声波液位计探头
FDU92-AG4A 超声波液位计探头
FDU92-AG5A 超声波液位计探头
FDU92-AG6A 超声波液位计探头
FDU92-AN1A 超声波液位计探头
FDU92-AN2A 超声波液位计探头
FDU92-AN3A 超声波液位计探头
FDU92-AN4A 超声波液位计探头
FDU92-AN5A 超声波液位计探头
FDU92-AN6A 超声波液位计探头
FDU92-JG1A 超声波液位计探头
FDU92-JG2A 超声波液位计探头
FDU92-JG3A 超声波液位计探头
FDU92-JG4A 超声波液位计探头
FDU92-JG5A 超声波液位计探头
FDU92-JG6A 超声波液位计探头
FDU92-JN1A 超声波液位计探头
FDU92-JN2A 超声波液位计探头
FDU92-JN3A 超声波液位计探头
FDU92-JN4A 超声波液位计探头
FDU92-JN5A 超声波液位计探头
FDU92-JN6A 超声波液位计探头
FDU92-LG1A 超声波液位计探头
FDU92-LG2A 超声波液位计探头
FDU92-LG3A 超声波液位计探头
FDU92-LG4A 超声波液位计探头
FDU92-LG5A 超声波液位计探头
FDU92-LG6A 超声波液位计探头
FDU92-LN1A 超声波液位计探头
FDU92-LN2A 超声波液位计探头
FDU92-LN3A 超声波液位计探头
FDU92-LN4A 超声波液位计探头
FDU92-LN5A 超声波液位计探头
FDU92-LN6A 超声波液位计探头
FDU92-RG1A 超声波液位计探头
FDU92-RG2A 超声波液位计探头
FDU92-RG3A 超声波液位计探头
FDU92-RG4A 超声波液位计探头
FDU92-RG5A 超声波液位计探头
FDU92-RG6A 超声波液位计探头
FDU92-RN1A 超声波液位计探头
FDU92-RN2A 超声波液位计探头
FDU92-RN3A 超声波液位计探头
FDU92-RN4A 超声波液位计探头
FDU92-RN5A 超声波液位计探头
FDU92-RN6A 超声波液位计探头
市政污水处理

市政污水处理污水处理厂 · 超声波应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 超声波应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 超声波应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 超声波应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。