Technical Data
CompareAnalyser
| Measuring Principle | UV absorbance |
| Characteristic | Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
| Measuring method | UV/VIS Absorbance at 200 to 800 nm |
| Size | 571.4 x 40 mm 21.5 x 1.6 in |
| Design | 40 mm |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Ambient temperature | -20 to 60°C -4 to 140 °F |
| Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
| Specials | G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60 days |
| Application | Monitoring of WWTP in- and outlet Drinking water and surface water |
| Measuring range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 8000 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 4000 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 1000 mg/l APHA/Hazen: 0 to 12500 Hazen |
Concentration
| Measuring Principle | UV absorbance |
| Product headline | Multiparameter Sensor for water analysis. Process control and quality monitoring in the field of wastewater, drinking water and surface water. |
| Application | Monitoring of WWTP in- and outlet, drinking water and surface water |
| Characteristic | Insitu (immersion in process) Extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
| Measuring range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 8000 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 4000 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 1000 mg/l APHA/Hazen: 0 to 12500 Hazen |
| Design | 40 mm |
| Material | Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
| Temperature sensor | -20 to 60°C -4 to 140 °F |
| Connection | G1 and NPT 3/4" |
| Ingress protection | IP68 |
Turbidity
| Measuring Principle | Absorption |
| Application | Monitoring of WWTP in- and outlet Drinking water and surface water |
| Installation | Insitu (immersion in process), extractive with sample and flow cell |
| Characteristic | Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
| Measuring range | "Depending on the path length and the application the measuring range vary: TOCeq: 0 to 8000 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 4000 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 1000 mg/l APHA/Hazen: 0 to 12500 Hazen |
| Measuring principle | UV/VIS absorbance at 200 to 800 nm |
| Design | 40 mm |
| Material | Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM |
| Dimension | 571.4 x 40 mm 21.5 x 1.6 in |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
| Temperature sensor | -20 to 60°C -4 to 140 °F |
| Connection | G1 and NPT 3/4" |
| Ingress protection | IP68 |
The Memosens Wave CAS80E reliably delivers real-time measuring results of relevant analysis parameters and measures chemical and biological oxygen demand (COD, BOD), turbidity, nitrate and spectral absorption coefficient in a single device. This increases the efficiency of the measuring point and minimizes operating costs. The Memosens Wave CAS80E full-spectrum sensor is compact and easy to use, and installation and maintenance are very simple. It uses Memosens digital sensor technology for reliable non-contact data transmission.
Advantages
Direct online operation for uninterrupted measuring results.
Memosens digital sensor technology for reliable non-contact data communication.
Supports analysis of multiple standard parameters for water and wastewater monitoring. Measurable parameters on demand: turbidity, suspended solids concentration, CODeq, BODeq, TOCeq, SAC254, nitrate and APHA-Hazen color.
The full-spectrum sensor contains different analysis models and adapts quickly to actual application conditions.
Compact, lightweight full-spectrum sensor with convenient installation and low maintenance costs
Application areas
The Memosens Wave CAS80E full-spectrum sensor can measure multiple analysis parameters and is widely used in:
Drinking water
Surface water
Wastewater
Industrial wastewater
Utilities
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
A
Source:Endress+Hauserpublic information from the website
Case Studies
市政污水处理污水处理厂 · EH-ONLINE应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · EH-ONLINE应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · EH-ONLINE应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · EH-ONLINE应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;