五参数水质分析仪
Technical Data
CompareAnalyser
| Measuring Principle | UV photometric |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay 2x relay, SD card for software update and copy & paste of setup |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs Alarmrelay, 2x relay |
| Input | 1 to 2x Memosens digital input |
Concentration
| Measuring Principle | Fluorescence measurement |
Conductivity
| Measuring Principle | Conductive |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 2x Memosens digital input |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs Alarmrelay, 2x relay |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
Disinfection
| Measuring Principle | Free chlorine |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 7.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Input | 1 to 2x Memosens digital input |
| Output / communication | 2 to 4x 0/4 to 20 mA current outputs Alarmrelay, 2x relay |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 2x Memosens digital input |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs Alarmrelay, 2x relay |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 7.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP67 |
| Input | 1 to 2x Memosens digital input |
| Output / communication | 2 to 4x 0/4...20 mA current outputs Alarmrelay, 2x relay |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
Sludge Level
| Measuring Principle | Ultrasonic sensor |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 7.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 2x Memosens digital input 2x 0/4 to 20mA input optional 2x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
Turbidity
| Measuring Principle | Four beam alternating light |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 7.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 2x Memosens digital input 2x 0/4 to 20mA input optional 2x Digital input optional |
| Output / communication | 2 to 4x 0/4 to 20 mA current outputs, Alarmrelay, 2x relay |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
pH
| Measuring Principle | Potentiometric |
| Application | Modular 4 wire controller Multichannel: 1/2 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity Two sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 2x Memosens input, 2 to 4x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal: EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 60 °C (0 to 140 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 2x Memosens digital input 2x 0/4 to 20mA input optional 2x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus, MCERTS |
The CM442 is intended for non-hazardous areas. For hazardous-area applications, please select the CM42.
If no degree of protection is required, e.g. for cabinet installation, use the CM442R.
The Liquiline CM442 digital multiparameter transmitter is suitable for all process monitoring and control applications. The 1-/2-channel controller offers seamless system integration, simple operation and reduced spare parts storage, saving time and costs. The Liquiline CM442 is not only easy to operate but also ensures maximum process safety, making it a first-class transmitter platform.
Benefits:
Simple and flexible: one controller for all parameter measurements, intuitive user interface, automatic sensor recognition and precalibrated Memosens sensors for plug and play.
High adaptability: universal modules reduce spare parts inventory and allow easy expansion to an eight-channel measuring system at any time
Seamless system integration: unique combination of communication standards for all types of distributed control systems (DCS)
Simple and safe commissioning: communication with other devices via SD card for convenient setup, saving time and cost
Process control and safety: via the built-in web server, operators can access diagnostic data and parameters remotely, or access device parameters from any web browser - even from a smartphone.
Application areas:
The Liquiline CM442 multiparameter transmitter is suitable for all non-hazardous areas, including the following industries and their utilities:
Food & Beverage
Life sciences
Power & Energy
Water & Wastewater
Chemical industry
The Liquiline CM442 is compatible with all common communication protocols and interfaces, such as:
0/4...20 mA
HART
PROFIBUS DP
Modbus TCP / Modbus RS485
EtherNet/IP
Web server
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
This product has passed the Chinese environmental certification, a mandatory certificate for wastewater treatment plant projects:

Measuring principle video
Source: public information from the Endress+Hauser website
Related Models
| Model | Name |
|---|---|
| CM442-8AM1A2F210B | 五参数水质分析仪 |
| CM442-AAM1A2F010A+AK | 五参数水质分析仪 |
| CM442-AAM1A2F060A+AK (CM442-4NM3/0) | 五参数水质分析仪 |
| CM442-AAM1A2F060B+AK | 五参数水质分析仪 |
| CM442-AAM1A2F061A+AK | 五参数水质分析仪 |
| CM442-AAM1A2F210A+AK | 五参数水质分析仪 |
| CM442-AAM1B8F010A+AK | 五参数水质分析仪 |
| CM442-AAM2A1FD10B+AK | 五参数水质分析仪 |
| CM442-AAM2A2F010A+AK | 五参数水质分析仪 |
| CM442-AAM2B8F010A+AK | 五参数水质分析仪 |
| CM442-AAN1B6F010A+ABHH | 五参数水质分析仪 |
Case Studies
市政污水处理污水处理厂 · 多参数应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 多参数应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 多参数应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 多参数应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。