Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CPS11E Digital pH sensor

CPS11E  Digital pH sensor

PH电极

Configurable Models 77 models
Memosens 2.0 pH electrode for standard applications in process and water & wastewater industries
Compare

pH

Measuring Principle Potentiometric
Application Long-term monitoring and limit control in processes with stable process conditions
Water and wastewater treatment
Characteristic Digital pH electrode for standard applications in process and environmental technology with dirt-repellent PTFE ring junction and built-in temperature sensor
Measuring range Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
Application F
• pH: 0 to 10
Measuring principle Gel compact electrode with PTFE ring junction
Design All shaft lengths with temperature sensor
Advanced gel technology
Material Sensor shaft: Glass to suit process
pH membrane glass: Type A, B, F
Metal lead: Ag/AgCl
Aperture: Ring-shaped PTFE junction
O-ring: FKM
Process coupling: PPS fibre-glass reinforced
Nameplate: ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.17 and 16.73 inch)
Process temperature Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F)
Application F: 0 to 70 °C (32 to 158 °F)
Process pressure Applications A and B:
0.8 to 17 bar (11.6 to 246.5 psi) absolute
Application F:
0.8 to 7 bar (11.6 to 101.5 psi) absolute
Temperature sensor NTC 30K
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

Field of application
Memosens CPS11E is the digital all-rounder for stable processes. It measures reliably even in extreme pH ranges or hazardous areas. Thanks to Memosens 2.0 digital technology, the pH sensor resists moisture and enables lab calibration, increasing process safety and simplifying operation. Its extended storage of calibration and process data provides the perfect basis for predictive maintenance. Designed for a long operating life and low maintenance, Memosens CPS11E offers you best value for money.
Long-term monitoring and limit monitoring of processes with stable process conditions:
- Chemical industry
- Pulp & paper industry
- Power plants (e.g. flue gas washers, boiler feed water)
- Incineration plants
Water & wastewater treatment:
- Drinking water
- Cooling water
- Well water
- Wastewater treatment plants
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

 

Benefits
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Low operating costs: Lab calibration and quick sensor exchange in the process result in minimized process downtime and longer sensor lifetime.
Robust, low maintenance electrode: Long poison diffusion path or optimized ion trap prevent poisoning of the electrode reference. Large, dirt-repellent PTFE junction protects from soiling by the medium.
Process glass is suitable for the full pH range and pressure-stable up to 17 bar (246.5 psi) absolute. Optional F-glass allows application in media containing hydrofluoric acid such as etching baths in semiconductor production.
Improved optional salt storage ensures reliable measurement in low conductivity applications such as boiler feed water.
Maximum process integrity through non-contact, inductive signal transmission.

Measuring Principle Potentiometric
Application Long-term monitoring and limit control in processes with stable process conditions
Water and wastewater treatment
Characteristic Digital pH electrode for standard applications in process and environmental technology with dirt-repellent PTFE ring junction and built-in temperature sensor
Measuring range Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
Application F
• pH: 0 to 10
 
Measuring principle Gel compact electrode with PTFE ring junction
Design All shaft lengths with temperature sensor
Advanced gel technology
 
Material Sensor shaft: Glass to suit process
pH membrane glass: Type A, B, F
Metal lead: Ag/AgCl
Aperture: Ring-shaped PTFE junction
O-ring: FKM
Process coupling: PPS fibre-glass reinforced
Nameplate: ceramic metal oxide
 
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.17 and 16.73 inch)
Process temperature Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F)
Application F: 0 to 70 °C (32 to 158 °F)
 
Process pressure Applications A and B:
0.8 to 17 bar (11.6 to 246.5 psi) absolute
Application F:
0.8 to 7 bar (11.6 to 101.5 psi) absolute
 
Temperature sensor NTC 30K
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68
Model Name
CPS11E-AA7AAA2 PH电极
CPS11E-AA7AAS2 PH电极
CPS11E-AA7ATA2 PH电极
CPS11E-AA7BAA2 PH电极
CPS11E-AA7BAA2+HC PH电极
CPS11E-AA7BAA5 PH电极
CPS11E-AA7BAA6 PH电极
CPS11E-AA7BTA2 PH电极
CPS11E-AA7FAA2 PH电极
CPS11E-BA7AAA2 PH电极
CPS11E-BA7AAS2 PH电极
CPS11E-BA7ASA2 PH电极
CPS11E-BA7BAA2 PH电极
CPS11E-BA7BAA2+HC PH电极
CPS11E-BA7BAA4 PH电极
CPS11E-BA7BAA5 PH电极
CPS11E-BA7BAA6 PH电极
CPS11E-BA7BTA2 PH电极
CPS11E-BA7FAA2 PH电极
CPS11E-CB7AAA2 PH电极
CPS11E-CB7ASA2 PH电极
CPS11E-CB7BAA2 PH电极
CPS11E-CB7BAA4 PH电极
CPS11E-CB7BTA2 PH电极
CPS11E-CB7FAA2 PH电极
CPS11E-CI7AAA2 PH电极
CPS11E-CI7ASA2 PH电极
CPS11E-CI7BAA2 PH电极
CPS11E-CI7BAA4 PH电极
CPS11E-CI7BTA2 PH电极
CPS11E-CI7FAA2 PH电极
CPS11E-GR7AAA2 PH电极
CPS11E-GR7ASA2 PH电极
CPS11E-GR7BAA2 PH电极
CPS11E-GR7BAA4 PH电极
CPS11E-GR7BTA2 PH电极
CPS11E-GR7FAA2 PH电极
CPS11E-IA7AAA2 PH电极
CPS11E-IA7ASA2 PH电极
CPS11E-IA7BAA2 PH电极
CPS11E-IA7BAA4 PH电极
CPS11E-IA7BTA2 PH电极
CPS11E-IA7FAA2 PH电极
CPS11E-JA7AAA2 PH电极
CPS11E-JA7ASA2 PH电极
CPS11E-JA7BAA2 PH电极
CPS11E-JA7BAA4 PH电极
CPS11E-JA7BTA2 PH电极
CPS11E-JA7FAA2 PH电极
CPS11E-KA7AAA2 PH电极
CPS11E-KA7ASA2 PH电极
CPS11E-KA7BAA2 PH电极
CPS11E-KA7BAA4 PH电极
CPS11E-KA7BTA2 PH电极
CPS11E-KA7FAA2 PH电极
CPS11E-MA7ASA2 PH电极
CPS11E-MA7BAA4 PH电极
CPS11E-MA7FAA2 PH电极
CPS11E-NA7AAA2 PH电极
CPS11E-NA7ASA2 PH电极
CPS11E-NA7ATA2 PH电极
CPS11E-NA7BAA2 PH电极
CPS11E-NA7BAA4 PH电极
CPS11E-NA7BTA2 PH电极
CPS11E-NA7FAA2 PH电极
CPS11E-UA7AAA2 PH电极
CPS11E-UA7ASA2 PH电极
CPS11E-UA7BAA2 PH电极
CPS11E-UA7BAA4 PH电极
CPS11E-UA7BTA2 PH电极
CPS11E-UA7FAA2 PH电极
CPS11E-UR7AAA2 PH电极
CPS11E-UR7ASA2 PH电极
CPS11E-UR7BAA2 PH电极
CPS11E-UR7BAA4 PH电极
CPS11E-UR7BTA2 PH电极
CPS11E-UR7FAA2 PH电极
市政污水处理

市政污水处理污水处理厂 · PH应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · PH应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · PH应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · PH应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。