The Prosonic Flow W clamp-on sensor was specially designed for water and wastewater applications. Combined with the Prosonic Flow 93 transmitter with touch control, four-line display and extended functionality, Prosonic Flow 93W offers high accuracy in standard applications in the water industry.
Compare

Liquids

Measuring Principle
Product headline std_productprofile_product_usp_8187.
Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.
Sensor features Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability.
std_successorproducts_product_differentiating_tech_features_8195_1571901112. std_successorproducts_product_differentiating_tech_features_8196_1571901112. std_successorproducts_product_differentiating_tech_features_8198_1571901212.
Transmitter features std_productprofile_product_benefits_8192. std_productprofile_product_benefits_8193. Automatic recovery of data for servicing.
std_successorproducts_product_differentiating_tech_features_58673_1571901772. std_successorproducts_product_differentiating_tech_features_58675_1571901824. std_successorproducts_product_differentiating_tech_features_58674_1571901824.
Nominal diameter range Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Wetted materials Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
Measured variables Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer
Max. measurement error Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
Measuring range 0.3 to 10 m/s (1 to 33 ft/s)
Max. process pressure N/A
Medium temperature range Clamp-on: –20 to +80 °C (–4 to +176 °F)
Insertion version: –40 to +80 °C
Ambient temperature range -20 to +60 °C (-4 to +140 °F)
Sensor housing material N/A
Transmitter housing material Wall-mounted housing: powder-coated die-cast aluminum
Degree of protection IP67, type 4X for transmitter, IP68 (option)
IP67 type 4X for sensors
IP68 type 6P for sensors (option). Transmitter: IP67, type 4X enclosure
Display/Operation 4 lines backlit display with three optical keys
Outputs 1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)
Inputs N/A
Digital communication HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus
Power supply AC 85 to 260 V
AC 20 to 55 V
DC 16 to 62 V
Hazardous area approvals ATEX, FM, CSA
Other approvals and certificates Flowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only
Marine certificate
EAC marking
Product safety CE, C-Tick, EAC marking
Metrological approvals and certificates Flowmeter verification for DN15, 25, 40, 50, 100, 250, 400 only
Marine approvals and certificates Marine certificate

The Prosonic Flow 93W clamp-on sensor is designed specifically for water and wastewater flow measurement. Combined with the Prosonic Flow 93 transmitter featuring touch control, a four-line display and numerous extended functions, the Prosonic Flow 93W delivers extremely high accuracy in standard applications in the water industry.

Advantages
Low investment cost - the larger the pipe diameter (up to DN 4000), the better the cost-effectiveness of the investment
No leaks - measurement takes place directly outside the pipe
High process transparency - with diagnostic functions
Optimum performance - extended functions and diagnostic software
Flexible data transmission - a choice of communication methods
Automatic data recovery for service purposes

Application areas
Choice of measuring principle not limited by pressure, density, temperature, conductivity and viscosity
Clamp-on flow measurement for measuring process water, brine, demineralized water, drinking water and wastewater
Instrument features
Medium temperature: –20~ +80 °C (-4 ~ +176 °F)
Degree of protection IP68 (6P housing) for underwater pipe flow measurement
Shock and vibration resistance in accordance with IEC 68-2-6
Aluminum transmitter housing
Four-line backlit display, touch control
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus

 

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

   

Measuring principle video

Source:Endress+Hauserpublic information from the website

市政污水处理

市政污水处理污水处理厂 · 超声波流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对超声波流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 超声波流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对超声波流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 超声波流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对超声波流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 超声波流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对超声波流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。