Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

伺服罐表 NMS83

伺服罐表 NMS83

伺服罐表 NMS83

The intelligent tank gauge Proservo NMS83 is designed for high accuracy liquid level measurement in custody transfer and inventory control applications with NMi- and PTB-approvals. It meets all requirements for hygienic applications. It fulfills the exact demands of tank inventory management and loss control and is optimized in regards of total cost saving and safe operation.
Compare

Continuous / Liquids

Measuring Principle Servo / Float Tank Gauging
Characteristic / Application Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications
Specialities Custody transfer level measurement
Interface measurement
Spot density, density profile measurement
Supply / Communication 85-264VAC
52-74VAC
19-64VDC
Accuracy up to 0.4 mm
Ambient temperature Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature -200°C...200°C
(-328°F...392°F)
Process pressure / max. overpressure limit 6 bar abs
Main wetted parts 316L, AlloyC276, PTFE
Process connection Flange:
DN80/3" / DN150/6"
Max. measurement distance 22 m (72 ft)
Communication Outputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / Approvals TIIS
Safety approvals Overfill protection WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
Options Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
Application limits Stilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Interface measurement requires min. difference of 0.100 g/ml
between layers

Density

Measuring Principle Servo / Float Tank Gauging
Characteristic / Application Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications
Supply / Communication 85-264VAC
Ambient temperature Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature -200°C...200°C
(-328°F...392°F)
Process pressure 6 bar abs
Wetted parts 316L, AlloyC276, PTFE
Output Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / Approvals ATEX, FM, IEC Ex, NEPSI, EAC
Options Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
Specialities Custody transfer level measurement
Interface measurement
Spot density, density profile measurement
Measuring range 22 m (72 ft)
Other approvals and certificates EN 10204-3.1
NACE MR0175, MR0103
OIML, NMi, PTB

The Proservo NMS83 intelligent tank gauge enables high-precision level measurement in custody transfer and inventory control applications, and is certified by NMi and PTB. It meets all the requirements of hygienic applications. It satisfies the strict requirements of tank farm inventory management and loss control, and has been optimized for total cost savings and safe operation.

Advantages
Hardware and software design complies with IEC 61508, with maximum safety SIL3 (in homogeneous redundant systems)
Maximum measuring accuracy of ±0.4mm (±0.02"), resulting in maximum reliability
Design complies with international metrology regulations such as OIML R85 and API MPMS standards
Local and national approvals, such as NMi or PTB approval for custody transfer applications
Simple connection to higher-level DCS systems via open protocols, simple installation and trouble-free operation
Measurement of up to three interfaces, tank bottom, single-point temperature and density profile

Application areas
High-precision custody transfer measurement of beer, whisky, wine and sake.
Process connection: flange
Temperature: -200...+200°C (-328...+392°F)
Pressure: 0...+6bar (0...+87psi)
Measuring range: Max. 22 m (72 ft)
Measuring accuracy: ±0.4 mm (±0.02")
International explosion protection and custody transfer approvals, WHG overfill protection and SIL approval

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

市政污水处理

市政污水处理污水处理厂 · 罐区应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对罐区的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 罐区应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对罐区的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 罐区应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对罐区的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 罐区应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对罐区的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。