Nr Order No. Specifications
34 71108602 I/O Modules
Non-Ex, Ex.
Current output, 4-20mA HART 4-20mA
analog.
Usage: FTM50/FTM51/FTM52.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
34 71164940 I/O Modules
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200
Promag 200.
71128617 Overvoltage protector
4-20mA HART.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
71128619 Overvoltage protector
4-20mA HART, PROFIBUS PA, FOUNDATION
Fieldbus, Imp./Freq./Switch output.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
71197334 transmitter FHX50
Consists:
electronics, ribbon cable.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass200, Prowirl 200
Promag 200, Prosonic Flow 200.
Remote display FHX50 please order
separate order structure.
71296840 Plug M12, VA
To connect FHX50.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Not for dust Ex.
Usage: Prowirl 200, Promass 200
Promag 200, Prosonic Flow 200.
30 XPD0001- Electronic Promass 200 / TB2
Main electronic module
71206552 cable
Connection cable, shielded.
Usage: FHX50.
71206554 cable
Connection cable, shielded.
Usage: FHX50.
71206555 cable
Connection cable, shielded.
Usage: FHX50.
34 XPD0015- I /O module, 2-wire, 4-20mA, HART, Ex
Non-Ex, Ex.
1x current output HART.

71206556 cable
Connection cable, shielded.
Usage: FHX50.
37 71110280 Terminal Kit 2-Wiring, I/O Modules
Consists:
4x terminal 2-pole, green.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
34 XPD0016- I /O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex.
1x current output HART.
1x PFS= pulse/freq./switch output.

40 XPD0024- Display module, SD02, push buttons
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
t-mass 150, Promag 200, Prowirl 200.
Consists:
Display SD02, helix cable
ribbon cable, connector cover.
40 XPD0025- Display module, SD03, Touch Control
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
Promag 200, Prowirl 200.
Consists:
Display SD03 illuminated, ribbon cable
connector cover.
20 71110281 aluminum cover
Material: 316L.
O-ring, EPDM, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
20 71110282 aluminum cover
Material: 316L.
O-ring NBR, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67, FHX50.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110291 aluminum cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110284 aluminum cover
Material: 316L.
O-ring EPDM /PTFE coated.
Usage: terminal compartment Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71185516 Cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMP54/FMP56/FMP57, FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Prowirl 200.
20 71110299 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
20 71110297 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71110301 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71110302 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71185517 aluminum cover
Material: aluminium.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
15 50103658 cable plug
15 50098036 explosion-proof cable plug
Kit 10 cable glands M20x1.5 Ex
15 71069285 Cable Plug Assembly
15 50098041 Adapter
Kit 10 extension M20x1.5/G 1/2"
15 71115505 M20x1.5/G 1/2 "adapter
15 50098042 Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15 71115509 M20x1,5/NPT1/2 "adapter
15 50098037 PA master cable plug
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
15 50094984 FF master cable plug
Kit Cable gland Found. Fieldbus
65 71110303 Enclosure Seal Kit
Consists:
O-ring 88.5x3.53 EPDM/PTFE
cover electronics compartment
housing GT19.
O-Ring 88.5x3.53 NBR
cover electronics compartment
housing GT18, GT20.
O-ring 91.67x3.53 EPDM/PTFE
cover terminal compartment
housing GT19.
O-Ring 91.67x3.53 NBR
cover terminal compartment
housing GT18, GT20.
O-ring 50.39x3.53 EPDM/PTFE
housing/sensor.
FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
19 71115174 housing filter plug (304)
Consists:
2x filter plug metall 316L.
1x pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
19 71115175 Housing Filter Plug (Brass/Nickel)
Consists:
2x filter plug brass nickel
pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
17 71115176 Housing Set Clips
Usage: housing GT18/GT19/GT20
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
71162242 Cover | GT18/GT19/GT 20,316L
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/
FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200, Prowirl
200.
8X2BXX- Transmitter Promass 200, 8X2BXX, <=DN50
For Product 8E2B 8F2B <= DN50 2"
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.