Nr Order No. Specifications
71367427 Spare parts kit ring D21/di 10xgreen,10p
Packing unit: 10 pieces
71389488 Extension cable TC IEC 2x type K
L=180mm, 3 pieces
TPC100- thermocouple armored core TPC100
Replaceable insert (MgO)
Approval:
A Non-hazardous area
B ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
Insertion Length IL:
XX ..... mm
YY ..... mm, TSP-no. to be spec.
Insert Diameter:
2 6mm
Head Transmitter; Range:
C Terminal block
F Flying leads
TC Type; Class; Material:
B 2x type K, cl. 1; Alloy600, max.1100oC
TC Standard; Hot Junction:
1 EN 60584 std.; ungrounded
TS111- iTHERM TS111 core
Replaceable.
Metric version according DIN43735.
Approval:
AA Non-hazardous area
BA ATEX II1G Ex ia IIC T6
Sensor Version:
1 RTD
Sensor Type; Measuring Range:
1B PT100 TF, StrongSens vibration resistant up to 60g; -50... 500oC
Insert Diameter:
C 6mm
Sensor Standard:
1 IEC 60751 (a=0.03851 Ohm/K)
Accuracy Class Insert:
1 Class A (IEC 60751)
Number of Sensors:
212 1x StrongSens, class A, 6mm
Sheath Material; Insert Design:
AC2 316L; 4-wire MI-Cable (6mm)
Insert Length:
X1 ..... mm (=<965)
YY Special version, TSP-no. to be spec.
Electrical Connection:
0A Flying leads
1A Terminal block
MLTWS01- Thermowell MLTWS01
Flanged protection tube
Head Connection:
A Fitting M24x1,5
Y Special version, TSP-no. to be spec.
Pipe diameter; Material:
1 16x 10mm; 1.4571
9 Special version, TSP-no. to be spec.
Neck Length E:
A0 ***W/o
A1 125mm
A2 135mm
A3 145mm
A4 155mm
X8 ..... mm
YY Special version, TSP-no. to be spec.
Process Connection:
AA ***W/o
AB Flange DN25 PN40 B1 EN1092-1, 1.4571
AC Flange DN25 PN63 B2 EN1092-1, 1.4571
YY Special version, TSP-no. to be spec.
Tip Shape:
1 Reduced 12x7x50 mm, 1.4571
9 Special version, TSP-no. to be spec.
Immersion Length L:
A1 235mm
A2 265mm
A3 325mm
A4 445mm
YY Special version, TSP-no. to be spec.
>>Test, Certificate:
JA 3.1 Material certificate, wetted metallic parts, EN10204-3.1 inspection certificate
JC 3.1 Material certificate short form, wetted metallic parts, EN10204-3.1 inspection certificate
K4 Dye penetrant acc. to ASME V and EN571-1 TW welding, inspection certificate
KE Pressure test, external procedure, inspection certificate
>>Marking:
Z2 Tagging (TAG), on device
TMT182- module temperature transmitter TMT182
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, SIL2, galvanic isolation
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN43729.
UL listed.
GL (German Llyod) Marine.
Approval:
A Non-hazardous area
B ATEX II1G Ex ia IIC T4/T5/T6
Configuration Connection:
1 ***Thermocouple TC, SIL2
4 ***RTD 4-wire, SIL2
Configuration Sensor Type:
1 Pt100, -200...850oC, min. span 10K, IEC751 (a = 0,00385)
K Type K, -200...1370oC, min. span 50K
Configuration:
B Measuring range, see additional spec.
Additional Option:
A Standard - DIN mounting set
TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical applications
by means of SIL 2/3 acc. to IEC61508.
Approval:
AA Non-hazardous area
BA ATEX II1G Ex ia IIC T4/T5/T6
Communication; Output Signal:
A HART; 1x 4-20 mA
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
A W/o, mounting set DIN standard
Configuration Universal Input:
C1 Ch1: RTD 4-wire, Ch2: inactive
D2 Ch1: TC, Ch2: TC
Sensor Type Input 1:
A1 Pt100, -200...850oC, min. span 10K, IEC60751 (a = 0.00385)
TK Type K, -270...1372oC, min. span 50K IEC 584
Sensor Type Input 2:
AA Inactive
TK Type K, IEC 584
Input; Interconnection:
A1 PV = CH1; CH2 inactive
A2 PV = CH1; SV = CH2
>>Additional Approval:
LA SIL conformity
>>Marking:
Z2 Tagging (TAG), on device
Z4 Tagging (TAG), Fieldbus
ZA Tagging (TAG), Descriptor
TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
Approval:
A1 Non-hazardous area
B1 ATEX II1G Ex ia IIC T4/T5/T6
Output Signal:
A PROFIBUS PA
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
C W/o
>Configuration Input:
C1 Ch1: RTD 4-wire, Ch2: inactive
D2 Ch1: TC, Ch2: TC
>Firmware Version:
78 01.01.zz, PROFIBUS PA, Profile 3.02, DevRev02
>>Marking:
Z2 Tagging (TAG), on device
Z4 Tagging (TAG), Fieldbus
Z5 Bus adress
TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
Approval:
A1 Non-hazardous area
B1 ATEX II1G Ex ia IIC T4/T5/T6
Output Signal:
A FOUNDATION Fieldbus H1
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
C W/o
>Configuration Input:
C1 Ch1: RTD 4-wire, Ch2: inactive
D2 Ch1: TC, Ch2: TC
>Firmware Version:
77 02.00.zz, FF, DevRev02
78 01.00.zz, FF, DevRev01
>>Marking:
Z2 Tagging (TAG), on device
Z4 Tagging (TAG), Fieldbus
Z5 Bus address