Nr Order Number Specifications
71249291 heat conduction oil FDA certification 30g
71312729 heat transfer oil HSC 340, 100g
52028179 Washer
Profile gasket for cover
Stainless steel housing F15
60017971 Display
Display LC for TA20J
71043745 Atmospheric compensation filter port
Consists:
filter plug plastic
Pressure compensation filter, O-ring.
Usage: housing F15.
Non Ex.
71090687 Fieldbus connector
71313382 Connector
71367414 copper sealing ring
Packing unit: 10 pieces
71367420 copper sealing ring
Packing unit: 10 pieces
71367425 copper sealing ring
Packing unit: 10 pieces
71367427 Gasket
Packing unit: 10 pieces
71438347 Spare parts kit copper ring M18
Packing unit: 10 pieces
C 71111510 ceramic terminal
C 71111514 ceramic terminal
71044061 Device Pack
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector
71389488 Extension Wire TC IEC 2x type K
L=180mm.
Packing unit: 3 pieces
71389497 Extension Wire TC IEC 2x type J
L=180mm.
Packing unit: 3 pieces
71586415 Spare parts kit O-ring TA20R
44.17x1.78 EPDM labs free, black
Packing unit: 5 pieces
71182602 seal
5x O-ring 3.69x 1.78
5x 0-ring 74.7x2.75
A TPC100- thermocouple armored core TPC100
Replaceable insert (MgO)
3
A
G
H
J
P
U
V
AA
AE
AF
AH
AJ
AL
AR
AU
XX
YY
1
2
C
F
A
B
E
F
Y
1
2
3
4
9
0
1
2
E
Y
0
9
E TN15- Neck extension TN15
Neck tube made from welded parts,
thread connection to a terminal head
form DIN B and different connections
a separate thermowell.
1
2
5
D
E
F
X
Y
B
E
Y
7
A
B
C
E
F
G
H
Y
0
9
D TA20A- **Junction box TA20A
Product being phased out
limited availability.
Connection head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material: Aluminium epoxy resin coating
Area temperature : max. 100 oC;
ATEX: 95 oC.
A
2
5
6
7
A
1
D TA20B- Junction Box TA20B
Connecting head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material:Polyamid black
Ambient temperature: max. 80 oC
Protection: IP65
A
2
C
1
D TA21E- Junction Box TA21E
Retainer for terminal block or head
transmitter.
Cover: srewable.
Material: Aluminum.
Max. temp.: 100 oC; ATEX 95 oC.
Protection: IP65.
A
1
A
B
C
B
A
F TA50- Mounting Mount Sleeve Fitting TA50
Screw in.
KC
B TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
A1
B1
B2
B4
D1
D3
E1
GA
GR
A
1
2
A
D1
D2
F1
B TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
A1
B1
B2
D1
D3
E1
GA
GR
A
1
2
A
D1
D2
F1
TID10- temperature transmitter display TID10
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84.
A1
B1
B2
B4
D1
E1
GA
GR
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
TXU10- Instrument debugging package TXU10
for PC-programmable devices
The program sets the connection line for a PC with USB interface
AA
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
D TA30A- lug TA30A
Retainer for terminal block or head
transmitter optional display.
Cover: low, hinged, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
A
B
1
2
A1
A2
A3
B1
B3
D TA30D- Terminal lug TA30D
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
A
B
C
B1
B3
D TA30P- junction box TA30P
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: Polyamid PA12 antistatic.
Colour: black.
Ambient temp.: -40...120oC (housing).
Protection: IP65 (housing).
1
A
TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
AA
B2
BA
GA
GR
IA
NA
NN
A
1
2
A
D1
D2
TJ
TK
AA
TJ
TK
A1
A2
F1
LA
TM131- industrial thermometer TM131
Modular thermometer with resistance
sensor or thermocouple.
Metrical version with exchangeable
insert for demanding applications in
chemical, oil/gas and power industry.
With thermowell or to be installed
into thermowell.
Measuring range: -200... 1.100oC/
-328...2.012oF
(depending on the configuration).
::Fastest response times for optimal
process control through iTHERM QuickSens
insert and fast response thermowell
options.
::Maximum robustness for highest process
safety through iTHERM StrongSens insert.
::Cost savings with recalibrations
through iTHERM QuickNeck coupling
::Material selection for a wide range
of applications.
AA