Nr Order No. Specifications
TMT142X-DA Spare parts TMT142X
Spare parts TMT142X
TMT142X-DB Spare parts TMT142X
Spare parts TMT142X
TMT142X-DC Spare parts TMT142X
Spare parts TMT142X
F TMT142X-HI Spare parts TMT142X
Spare parts TMT142X
F TMT142X-HL Spare parts TMT142X
Spare parts TMT142X
F TMT162X-HI Spare parts TMT162X
F TMT162X-HL Spare parts TMT162X
51006845 cable plug
Cable gland NPT 1/2, D4-8.5, IP68
51007995 Mounting Bracket
Mounting bracket SS316L, tube 1,5-3"
TMT162X-DA Spare parts TMT162X
TMT162X-DB Spare parts TMT162X
TMT162X-DC Spare parts TMT162X
TMT162X-DD Spare parts TMT162X
TMT162A-MA TMT162A Accessories
TMT162A-MB TMT162A Accessories
71111513 ceramic terminal
71111514 ceramic terminal
71502617 O-ring 88x 3 HNBR 70 ° Shore PTFE_5pcs
Packing unit: 5 pieces
A 71182606 seal
5x O-ring 57x2.5
5x O-ring 64.3x1.8 blau
71600564 Set O-ring 74x3 75° VMQ Silicon
Packing unit: 5 pieces
71386275
71044062 Device Pack
2x screws, 1x sealing CDI-connector
A TS212- iTHERM Insert imperial TS212
Replaceable insert acc. IEC 60751.
Imperial version with central spring
load.
::Fastest response times for optimal
process control through iTHERM
QuickSens.
::Maximum robustness for highest process
safety through iTHERM StrongSens.
AA
1
1B
1D
C
D
1
1
2
A1
A2
C2
D2
EA
EB
FA
FB
X1
B1
I7
SA
TG
TS
A TU111- General Purpose RTD Insert, TU111, U.S.
Spare part. Spring loaded.
General purpose.
Pt100 Sensor comply with IEC60751
standard, alpha=0.00385.
8
A
B
D
H
I
J
K
L
M
Y
A
A
B
C
D
E
F
G
H
J
K
L
M
2
1
B
J
K
1
F TA30H- junction box TA30H
Retainer for terminal block or head
transmitter optional display.
Design: explosion proof
Cover: screwed, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50#150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
Protection Ex d/XP: IP66/67 (housing).
A1
1
B
D
2
A TA30R- junction box TA30R
Retainer for terminal block
or head transmitter optional display.
Cover: screwed, optional window.
Material: Stainless Steel 316L.
Colour: Steel (no coating).
Ambient Temp.: -50...85/130 oC
(display/standard).
Protection: IP66/68, NEMA4X;
IP69K (housing).
:: easy wiring through best
accessibility.
:: compact desing and low weight.
A
B
2
B
1
2
F TU401- Enclosure TU401, US Style
A
1
A
B
A
B
E
1
4
A
Y
A
A XPT0004- Spare Parts Kit Cover TA30R
cover of connecting head
A
B
A
B
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
SFE500- Plant Asset Management System FieldCare SFE500
FieldCare is a software tool that
combines the best of the leading
device integration technologies FDT
and FDI. FieldCare is scalable which
allows to fulfill tasks from easy
Device Setup, Plant Asset Management
or Condition Monitoring (Asset Health
Monitoring).
FieldCare includes approved DTM and FDI
Package libraries from Endress Hauser
and third party.
Additional hardware e.g. modems or
communication interfaces are needed.
One year software update service is
included to guarantee top quality
security and performance via online
updates or download from
Endress Hauser Software Portal:
https://software-products.endress.com
N
TXU10- Instrument debugging package TXU10
for devices that can be PC-programmed and debugged
The program sets the connection line for a PC with USB interface
AA
AC
AD
TMT31- temperature transmitter TMT31
2-wire temperature transmitter.
Single sensor input.
Application: RTD.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC
presetting failure current low.
Mounting: head form B, DIN EN50446.
CA
A
1
A
1
A1
B2
B3
C1
PB
78
Z2
Z9
TMT71- temperature transmitter TMT71
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC.
CA
CE
A
P
1
A
AC
A1
B2
B3
C1
Z2
TMT72- temperature transmitter TMT72
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification: Pt100, 4-wire, 0... 100oC
CA
CE
A
P
1
A
AA
A1
B2
B3
C1
Z2
TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Presetting failure current high.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
8C
CA
CP
A
2
B
B1
B3
C1
A1
A1
AA
A1
A2
LA
ZE
TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
C1
C2
CA
CH
A
2
B
B1
B3
C1
ZE
TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
CA
CH
A
2
B
B1
B3
C1
TMT162E- Electronic Module TMT162E
Attention: Only 1 piece per position
orderable in offer/order because
item category group ZTA1.
A
B
A
B
D
E
F
G
H
I
J
K
K
F TMT162G- Shell TMT162G
A
A
F
K
1
A
TID10- temperature transmitter display TID10
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84.
A1
CA
TMT142E- Electronic Module TMT142E
Attention: Only 1 piece per position
orderable in offer/order because
item category group ZTA1.
A
B
A
B
C
K
F TMT142G- Shell TMT142G
Housing TMT142G
A
A
C
1
A