Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

2100QIS01

2100QIS01
Familia de producto: 2100Q Portable Turbidimeters
2100Q IS Portable Turbidimeter (LED), 0-1000 FNU
HACH 2100QIS01
Effortlessly monitor turbidity and ensure accurate water quality results with the Hach 2100Q Portable Turbidimeter, a durable, lightweight tool for field and lab applications alike. Designed with prac

产品概述

Effortlessly monitor turbidity and ensure accurate water quality results with the Hach 2100Q Portable Turbidimeter, a durable, lightweight tool for field and lab applications alike. Designed with practicality in mind, this device supports effective measurement in industrial processes and municipal water systems, helping you maintain confidence in your data every step of the way.

The 2100Q takes precision to the next level, offering reliable turbidity results tailored for global regulatory alignment. This model measures turbidity in Formazin Nephelometric Units (FNU), delivering results that meet international measurement requirements for your water quality programs.

Its user-friendly interface makes calibration and verification straightforward, freeing up time to focus on collecting and managing essential turbidity data.

Don’t wait to elevate your water quality testing standards. Order the Hach 2100Q Portable Turbidimeter today and trust in its proven performance.

主要特点

  • Easy on-screen assisted calibration and verification:Save time and get accurate results with an easy-to-follow interface that eliminates the need for complicated manuals to perform routine calibrations. Single-standard Rapidcal™ calibration offers a simplified solution for low level measurements, while ensuring you meet reporting requirements.
  • Simple data transfer:Data transfer with the optional USB+Power Module is simple, flexible, and doesn't require additional software. All data can be transferred to the module in XML format and easily downloaded to your computer with a USB connection, providing superior data integrity and availability.
  • Accurate for rapidly settling samples:The innovative Rapidly Settling Turbidity™ mode provides accurate measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.
  • Convenient data logging:Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages, and the result.
  • Optical system for precision in the field:The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.

技术参数

参数名称说明
Accuracy± 2 % of reading plus stray light from 0 - 1000 FNU
Battery Requirements4, AA
CertificationsCE certified
Compliance CertificationsCE/WEEE
Data Logging500 records
Dimensions (H x W x D)77 mm x 107 mm x 229 mm
Display Size240 x 160 pixels
Display TypeGraphic LCD
Enclosure RatingIP67
InterfaceNo USB and Power Cord
Light SourceLED
Manual LanguagesEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Max. operating humidity90
Measurement MethodRatio turbidimetric determination using a primary nephelometric light scatter signal and transmitted light scatter signal.
Measurement ModesNormal (Push to Read), Signal Averaging, Rapidly Settling Turbidity
Operating Temperature Range0 - 50 °C
Power Requirements100 - 240 V AC / 50/60 Hz (with optional Power or USB+Power module)
Power SupplyBatteries (see Battery Requirements) or Optional Power Supply
Range0 - 1000 FNU
Reading ModesNormal (Push to Read) Signal Averaging Rapidly Setting Turbidity
Repeatability± 1 % of reading or 0.01 FNU whichever is greater
Response Time6 s in normal reading mode
Sample Cell Compatibility25 mm x 60 mm round
Sample Requirements15 mL (0.5 oz)
Sample Volume15 mL
Signal AveragingSelectable on/off
Storage Conditions-40 °C to 60 °C
Stray Light< 0.02 FNU
UnitsFNU
User InterfaceButton GUI (Graphical User Interface)
User Interface LanguagesEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Warranty12 months
Weight0.53 kg without batteries
What's included?Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, Stablcal ampule kit, silicone oil, oiling cloth, manual.

应用领域

Groundwater · Municipal Water · QA/QC Lab · Surface Water

同系列其他配置

型号
2100Q012100Q Portable Turbidimeter (EPA), 0-1000 NTU
2100Q01USB2100Q Portable Turbidimeter Kit (EPA), 0-1000 NTU, with USB and Power
2100QIS01USB2100Q IS Portable Turbidimeter (LED), 0-1000 FNU, with USB and Power M

资料下载

4 modelos · clic para contraer