SPADNS 2 (Arsenic-free) Fluoride Reagent Accuvac® Ampules, pk/25
For a greener determination of Fluoride by ARSENIC-FREE Hach SPADNS 2 Method 10225, using Accuvac® Ampules. The SPADNS 2 reagent formulation removes interference from chlorine without arsenic to deliv
产品概述
For a greener determination of Fluoride by ARSENIC-FREE Hach SPADNS 2 Method 10225, using Accuvac® Ampules. The SPADNS 2 reagent formulation removes interference from chlorine without arsenic to deliver safer, EPA-compliant fluoride testing. Easy-to-use and EPA Compliant for use in Drinking Water and Wastewater reporting programs and equivalent to the EPA reference method SM 4500-F D.
Range: 0.02 - 2.00 mg/L F- Pack of 25 ampules
主要特点
- Fast:Use AccuVac® Ampules anywhere you need quick results. Just snap, fill and read - saving you valuable time.
- Easy:No need to measure sample or reagents. Ampules are both reagent containers and photometric measurement cells. The evacuated ampules draw in the correct sample volume, so anyone can obtain reliable results with minimal effort.
- Accurate:High sensitivity using 1-inch diameter vials. EPA Compliant for use in Drinking Water and Wastewater reporting programs and equivalent to the EPA reference method SM 4500-F D.
- Greener:The innovative, arsenic-free solution removes interference from Chlorine without arsenic to deliver safer EPA-compliant fluoride testing with a sustainable edge.
技术参数
| 参数名称 | 说明 |
|---|---|
| EPA compliant | Yes |
| Instrument | See Methods/Procedures for instruments compatible with this product |
| Method Name | SPADNS 2 |
| Method Number | 10225 |
| Number of tests | 25 |
| Parameter | Fluoride |
| Platform | Accuvac® |
| Quantity | 25 /pk |
| Range | 0.02 - 2.00 mg/L F- |
应用领域
Municipal Water · Potable Water
资料下载
- 시약정보요약서-CAS-Number-7647-01-0
- Hach Methods Quick Reference Guide : Australia
- Hach Methods Quick Reference Guide : New Zealand
- Hach Methods Quick Reference Guide : Singapore
- Phương pháp Hach Hướng dẫn tham khảo nhanh
- Hach Methods Quick Reference Guide
- GSA Supply Schedule
- Fluoride, SPADNS Method 8029 and SPADNS 2 Method 10225 AccuVac® Ampuls, Pocket Colorimeter II
Recomendados similares
HACHPhosphoric Acid Solution, 1.0 Molar 5 Gallon
Ver →
HACHAmino acid reagent powder pillows for LR silica, 25 mL, pk/1000
Ver →
A
HACHNutrients Basic Reagent Set, TNTplus
Ver →
HACHRochelle Salt-PVA Reagent, 500 mL
Ver →
HACHToluene, 4 L
Ver →
HACHSodium carbonate solution, 500 mL
Ver →
HACHRapid Silver Reagent Powder Pillows, pk/100
Ver →
HACHBottle, Storage, Glass, Reagent, 125 mL
Ver →