Familia de producto:
2582sc Dissolved Oxygen Analyzers
Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, LAN + Profibus DP, 100-240 VAC, without power cord
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your uniqu
产品概述
Simple to Integrate. Simple to Operate.
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your unique needs. The comprehensive approach saves you time on design, installation, training, maintenance, and operation.
主要特点
- Save Time on Design:A single design source and one product platform means you spend less time searching for design files or configuring components.
- Easy Adoption:The familiar experience with a modern touchscreen, the ability to use your current Hach sensor, and the same footprint as the 9500 Polymetron, make installation and integration of the SC4500 Controller seamless.
- The Connectivity Options You Need:The Controller provides local communication to SCADA or a PLC. From analog, to advanced digital protocols, to wi-fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.
- Simplify Maintenance and Operation:Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. Start-up and maintenance time are minimised with pre-mounted membrane cap and factory pre-conditioned sensors.
技术参数
| 参数名称 | 说明 |
|---|---|
| Operational Mode | Primary or secondary measurement or timer/scheduler |
| Analog Outputs | Five 0-20 mA or 4-20 mA analog outputs on analog output module |
| Cable Length | 10 m (33 ft) |
| Calibration Method | Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement |
| Communication | Modbus RS232/RS485, Profibus DPV1, Profinet optional |
| Communication | Analog: Five 0 - 20 mA or 4 - 20 mA analog outputs on each analog output module Up to two analog Input modules (0 - 20 mA or 4 - 20 mA). Each input module replaces a digital sensor input. Digital: Profibus DPV1 module Modbus TCP Profinet IO module Ethernet IP module |
| Communication Capabilities | Claros LAN + Profibus DP |
| Conduit Openings | ½" NPT Conduit |
| Connection Drain Line | 8 mm tubing |
| Connection Sample Line | ¼" NPT thread (6 mm or ¼" tubing advised) |
| Display | 3.5-inch TFT color display with capacitive touchpad |
| Electrical Certifications | CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, CMIM, Morocco |
| Enclosure Rating | UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish |
| Lower Limit of Detection (LOD) | < 1 ppb |
| Maintenance Interval | Membrane Lifetime: 6 months depending on sample |
| Material | Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl |
| Material Enclosures | Polycarbonate Aluminium (powder coated) Stainless Steel |
| Operating Temperature Range | -20 - 60 °C (-4 - 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 - 45 °C (-4 - 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 - 60 °C (-1.33 W/°C) |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 - 240 VAC |
| Power Supply | Without power cord |
| Range | 0 - 2000 ppb (0 - 2 ppm) |
| Relay Functions | Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning |
| Relays | Two relays (SPDT); Wire gauge: 0.75 - 1.5 mm² (18 - 16 AWG) AC controller Maximum switching voltage: 100 - 240 VAC Maximum switching current: 5 A Resistive/1 A Pilot Duty Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty DC controller Maximum switching voltage: 30 VAC or 42 VDC Maximum switching current: 4 A Resistive/1 A Pilot Duty Maximum switching power: 125 W Resistive/28 W Pilot Duty |
| Repeatability | ±0.5 ppb or ±5%, whichever is greater |
| Reproducibility | ±0.5 ppb or ±2% whichever is greater |
| Response Time | For step change 1 - 40 ppb: < 30 s |
| Sample Flow Rate | 66 - 166 |
| Security Levels | 2 |
| Software Available | Cloud (Claros-enabled) |
| Storage Conditions | -20 - 70 °C (-4 - 158 °F) |
| Temperature Compensation | Automatic in the range of 0 - 45 °C (32 - 113 °F) |
| Units | mg/L, ppm, µg/L, ppb, mbar, hPa, inch Hg, mmHg |
| Warranty | 12 months |
| Weight | 3.2 kg (7,2 lbs) |
| What's included? | Controller, mounting hardware, oxygen sensor, temperature sensor, cable, flow-chamber, basic user manual |
应用领域
Boiler Water · Cooling Water · Production Water
同系列其他配置
| 型号 | |
|---|---|
| 2582.99.A01801 | Polymetron 2582sc Dissolved Oxygen Analyzer, 5x mA Output, 100-240 VAC |
| 2582.99.A02801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Profibus DP, 100-240 VAC, |
| 2582.99.A06801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Profinet IO, 100-240 VAC, |
| 2582.99.A0B801 | Polymetron 2582sc Dissolved Oxygen Analyzer, LAN + mA Output, 100-240 |
| 2582.99.A0C801 | Polymetron 2582sc Dissolved Oxygen Analyzer, LAN + Profibus DP, 100-24 |
| 2582.99.A0F801 | Polymetron 2582sc Dissolved Oxygen Analyzer, LAN + Profinet IO, 100-24 |
| 2582.99.AA1801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, 5x mA Out |
| 2582.99.AA2801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, Profibus |
| 2582.99.AA6801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, Profinet |
| 2582.99.AAB801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, LAN + mA, |
| 2582.99.AAF801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, LAN + Pro |
| 2582.99.Z01801 | Polymetron 2582sc Dissolved Oxygen Analyzer, 5x mA Output, 24 VDC |
| 2582.99.Z02801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Profibus DP, 24 VDC |
| 2582.99.Z0B801 | Polymetron 2582sc Dissolved Oxygen Analyzer, LAN + mA Output, 24 VDC |
| 2582.99.Z0C801 | Polymetron 2582sc Dissolved Oxygen Analyzer, LAN + Profibus DP, 24 VDC |
| 2582.99.ZA1801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, 5x mA Out |
| 2582.99.ZA2801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, Profibus |
| 2582.99.ZAB801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, LAN + mA |
| 2582.99.ZAC801 | Polymetron 2582sc Dissolved Oxygen Analyzer, Claros-enabled, LAN + Pro |
资料下载
- The NEW SC4500 Controller : SC4500 Controller vs SC200 Controller vs SC9500 Controller
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- 2582sc Dissolved Oxygen Analyzer
- 2582sc 용존 산소 분석기
- Máy phân tích Oxy hòa tan 2582sc
- 2582sc Dissolved Oxygen Analyzer Drawing_2582.TD.1000_d1
- User Instructions : Ultrapure Amperometry Module
Recomendados similares
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
Ver →
A
HACHReplacement Protector for Clark DO sensor
Ver →
HACHField Service Partnership, 3100 LDO, 1 Service/Year
Ver →
HACHBench Service Partnership, 3100 LDO, 1 Service/Year
Ver →
HACHPocket Dissolved Oxygen (DO) Meter
Ver →
HACHHach BioTector B7000i TOC Analyzer
Ver →
HACHField Service Partnership, 2586sc Oxygen Scavenger Analyzer, 2 Services/Year
Ver →
HACHCOD TNTplus Vial Tests, LR