产品概述
Hach's answer to reagentless amperometric chlorine measurement.
The CLT10sc Total Chlorine Analyzer measures total chlorine continuously for real time process control. It is based on amperometric technology and comes with the sc200 digital controller. The CLT10sc can be used in most municipal and industrial applications, and is best utilized where waste stream management is a constraint. This analyzer is equipped with a pH sensor for use with Hach's unique Cal Watch advanced diagnostic feature.
主要特点
- Compatible with Hach's "Plug and Play" Digital Controllers:The CLF10 sc and CLT10 sc Chlorine Analyzers are designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.
- No Reagent Replacement, No Waste Stream:Chlorine measurement with the CLF10sc and CLT10sc amperometric technology eliminates the need for routine reagent replacement and waste stream management.
- EPA Compliance:The CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required for Method 334.0.
- Advanced Diagnostics:CLF10sc and CLT10sc advanced diagnostics alert you when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow.
- Real-time Process Monitoring and Control:The CLF10sc and CLT10sc Chlorine Analyzers allow for real-time monitoring and control of disinfection processes.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | Free Chlorine: ±3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit) |
| Accuracy 2 | Free Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Accuracy 3 | Total Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Accuracy 4 | Total Chlorine: ±20 % of the reference test** (DPD) at stable pH greater than 8.5 |
| Cable Connection | 5 pin, M12 connector |
| Cable Length | 1 m (between gateway and sc controller) |
| Calibration Method | (zero and slope) calibration |
| Calibration Method 2 | (zero and slope) calibration |
| Certifications | CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Additional certifications when connected to an sc controller |
| Connection Drain Line | pH Flow Cell Outlet: 1/2-inch ID |
| Connection Sample Line | 1/4 inch OD |
| Controller Compatibility | sc controller platform |
| Dimensions | Sensor Only: 195 |mm x 25 mm (7.68 in x 0.98 in) |
| Interferences | Monochloramine, chlorine dioxide, ozone, and chalk deposits |
| Length | Sensor: 195 mm |
| Lower Limit of Detection (LOD) | 30 ppb (0.03 ppm) |
| Material | Corrosion-resistant materials, fully-submersible (stainless steel, PEEK, PVC, silicon rubber and polycarbonate) |
| Measurement Method | Reagentless, electrochemical, three-electrode amperometric system |
| Mounting | Panel or Wall Mounting |
| Operating Temperature Range | 0 - 45 °C |
| pH Range | 4 - 9 |
| Power Requirements (Voltage) | 12 VDC |
| Pressure Range | 0.5 bar, no pressure impulses and/or vibrations |
| Range | 0 - 20 ppm Cl₂ |
| Response Time | Total Chlorine:100 sor less for 90% change (T90) at a stable temperature and pH |
| Response Time | Free Chlorine: 140 s or less for 90% change (T90) at a stable temperature and pH |
| Sample Flow Rate | 30 - 50 L/h (7.9 - 13.2 gal/hour), Optimal is 40 L/hour (10.5 gal/hour) |
| Sample Temperature | 5 - 45°C(41 - 113°F) |
| Ship Wt. (lbs) | 9.1 |
| Warranty | 1 Year |
| Weight | 5.5 kg Approximately 5.5 kg (12 lbs) Panel and empty panel-mounted components only |
| What's included? | SC200 Controller, Mounting Hardware, SC200 Basic User Manual, CL10sc Panel, 1 m digital extension cable, Panel Manual, Combination pH Sensor Manual, Chlorine Sensor Manual. |
资料下载
- Chlorination, Chloramination And Chlorine Measurement
- Reagentless Total Chlorine Probe for Wastewater Disinfection. Comparing the Hach® CLT10 sc and Wallace & Tiernan Micro/2000®
- Discovering the Unexpected in Disinfection Applications
- Chlorine Analyzer Customer Guide
- Máy phân tích Clo tổng & Clo tự do không cần hóa chất CLF10sc & CLT10sc
- CLF10sc & CLT10sc Free & Total Reagentless Chlorine Analyzers
- HACH SC200 Controller CSI Specification
- CLF10 sc and CLT10 sc CSI Specifications
Recomendados similares
9187sc Chlorine Dioxide Analyzer with sc100 controller and RS485
HACHElectrolyte for Chlorine/Ozone
HACHAT1000 Titration Bundle, Total Chlorine (Backward)
HACHSpecCheck kit de estándares secundarios en gel, cloro DPD - rango bajo (LR)
HACHIntroducción al analizador CL17sc (usuario único)
HACH8450 Free Chlorine Probe, 25 ft
HACHpHD sensor de pH, CLF10sc sensor de cloro residual libre, con controlador SC4500, 2 canales
HACH