Hach's answer to reagentless amperometric chlorine measurement.
The CLF10 sc analyzer uses Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow. Free chlorine measurement with an amperometric analyzer, such as the CLF10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management. The CLF10sc free chlorine analyzer allows for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed. Product includes free chlorine sensor, chlorine sensor block, sc200 controller, sc Gateway, stainless steel panel and pH flow cell for grab samples.
主要特点
- Compatible with Hach's "Plug and Play" Digital Controllers:The CLF10 sc and CLT10 sc analyzers leverage Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.
- EPA compliant according to Method 334.0:Chlorine measurement with an amperometric analyzer, such as the CLF10 sc or CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.
- Exclusive Self Diagnostics:The CLF10 sc and CLT10 sc analyzers allow for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.
- No Reagent Replacement, No Waste Stream:The CLF10 sc and CLT10 sc analyzers can be used with any Hach sc digital controller. Whether you're measuring turbidity or chlorine, you only need to learn one controller for all your water analysis measurement points. Hach sc controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it's ready to use without software configuration.
- Real-time Process Control:In accordance with EPA Method 334.0, the CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required in Method 334.0. (See page 4 for a partial listing of accessories.)
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | Free Chlorine: ±3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit) |
| Accuracy 2 | Free Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Accuracy 3 | Total Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Accuracy 4 | Total Chlorine: ±20 % of the reference test** (DPD) at stable pH greater than 8.5 |
| Cable Connection | 5 pin, M12 connector |
| Cable Length | 1 m (between gateway and sc controller) |
| Calibration Method | (zero and slope) calibration |
| Calibration Method 2 | (zero and slope) calibration |
| Certifications | CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Additional certifications when connected to an sc controller |
| Connection Drain Line | pH Flow Cell Outlet: 1/2-inch ID |
| Connection Sample Line | 1/4 inch OD |
| Controller Compatibility | sc controller platform |
| Dimensions | Sensor Only: 195 |mm x 25 mm (7.68 in x 0.98 in) |
| Interferences | Monochloramine, chlorine dioxide, ozone, and chalk deposits |
| Length | Sensor: 195 mm |
| Lower Limit of Detection (LOD) | 30 ppb (0.03 ppm) |
| Material | Corrosion-resistant materials, fully-submersible (stainless steel, PEEK, PVC, silicon rubber and polycarbonate) |
| Measurement Method | Reagentless, electrochemical, three-electrode amperometric system |
| Mounting | Panel or Wall Mounting |
| Operating Temperature Range | 0 - 45 °C |
| pH Range | 4 - 9 |
| Pressure Range | 0.5 bar, no pressure impulses and/or vibrations |
| Range | 0 - 20 ppm Cl₂ |
| Response Time | Total Chlorine:100 sor less for 90% change (T90) at a stable temperature and pH |
| Response Time | Free Chlorine: 140 s or less for 90% change (T90) at a stable temperature and pH |
| Sample Flow Rate | 30 - 50 L/h (7.9 - 13.2 gal/hour), Optimal is 40 L/hour (10.5 gal/hour) |
| Sample Temperature | 5 - 45°C(41 - 113°F) |
| Ship Wt. (lbs) | 9.1 |
| Warranty | 1 Year |
| Weight | 5.5 kg Approximately 5.5 kg (12 lbs) Panel and empty panel-mounted components only |
| What's included? | SC200 Controller, Mounting Hardware, SC200 Basic User Manual, CL10sc Panel, 1 m digital extension cable, Panel Manual, Combination pH Sensor Manual, Chlorine Sensor Manual. |
资料下载
- Chlorination, Chloramination And Chlorine Measurement
- Reagentless Total Chlorine Probe for Wastewater Disinfection. Comparing the Hach® CLT10 sc and Wallace & Tiernan Micro/2000®
- Discovering the Unexpected in Disinfection Applications
- Chlorine Analyzer Customer Guide
- Máy phân tích Clo tổng & Clo tự do không cần hóa chất CLF10sc & CLT10sc
- CLF10sc & CLT10sc Free & Total Reagentless Chlorine Analyzers
- CLF10 sc and CLT10 sc CSI Specifications
- CLF10 sc and CLT10 sc Dimensional Drawing
Recomendados similares
HACHSension Refillable combination pH electrode, 5-pin connector
HACHRadiometer Analytical PHC3031-9 Combination pH Electrode for Penetration Applications (glass body, Ag/AgCl ref., screw cap)
Radiometer Analytical PHC4006-9 Combination Calomel pH Electrode (l=158 mm, d=6.5 mm, glass body, screw cap)
pHC2501-8 Combined pH Electrode, Red Rod, Double Junction, BNC plug (Radiometer Analytical)
HACHpH Electrode Storage Solution, 500 mL
HACHRadiometer Analytical PHC2601-8 Combination Red-Rod pH Electrode (sleeve junction, glass body, BNC)
Radiometer Analytical PHC2401-7 Combination Red-Rod pH Electrode (glass body, type 7 plug)
HACH