3422 Series Analog Contacting Conductivity Sensors, Cell Constant k=0.5 cm⁻¹
3422 Series Analog Contacting Conductivity Sensors, Cell Constant k=0.5 cm⁻¹
产品概述
Nominal Cell Constant (K) = 0.5, 3/4 inch NPT 316 Stainless Steel Compression Fitting, Aluminum Junction Box with 3/4" NPT Conduit Connection - Requires 1W1100 Interconnect Cable, Titanium Electrode
主要特点
- High Performance Design:These enhanced performance sensors are manufactured to exacting tolerances using high quality, rugged materials for demanding applications including ultra-pure water, clean-in-place (CIP), and boiler/condensate monitoring. Each sensor is tested to determine its unique, absolute four-digit cell constant. Also, each sensor has a Pt 1000 RTD temperature element built into its tip for exceptionally fast response to changes in temperature with ±0.1ºC accuracy.
- Resistivity and Conductivity Measurement Capability:These enhanced performance sensors measure from theoretically pure water (0.057 µS/cm or 18.2 MΩ) up to 200,000 µS/cm. Hach’s Digital SC Controllers accept multiple digital sensor inputs, and can be user-set to measure conductivity, resistivity,TDS, salinity, or one of six calculated measurements.
- Versatile Mounting Styles:Compression fitting sensors—Feature titanium electrodes and a compression fitting for universal installation with up to 4 inches (102 mm) insertion depth. The 1/2-inch or 3/4-inch male NPT compression fittings are offered in PVDF or 316 stainless steel. A longer version of this sensor is available for use with a 316 stainless steel ball valve hardware assembly to insert/retract the sensor from the process without stopping the flow. The longer version can also be used for insertion through a compression fitting. Maximum insertion depth is 7 inches (178 mm).
- Full-Featured “Plug and Play” Hach SC Digital Controllers:There are no complicated wiring or set up procedures with any Hach SC controller. Just plug in any combination of Hach digital sensors and it's ready to use—it’s “plug and play.”
技术参数
| 参数名称 | 说明 |
|---|---|
| Cable Length | 6 m (20 ft) |
| Cell Constant k | 0.5 cm⁻¹ |
| Digital Gateway | Aluminium with 3/4" conduit connection |
| Electrode Material | Titanium |
| Installation style | Compression |
| Junction box | Aluminium |
| Material | Compression Fitting: 3/4" NPT Stainless Steel |
| Range | 0 - 1000 µS/cm |
| Sensor Type | Analog |
| Warranty | 12 months |
| What's included? | Includes: sensor with 6 m (20 ft) cable and manual |
应用领域
Boiler Water · Clean in Place (CIP) · Membrane Protection · Membrane Protection
同系列其他配置
| 型号 | |
|---|---|
| 3422B3A | Contacting Conductivity Sensor for Low Conductivity, K=0.5, 3/4" PVDF |
| 3422B3A20G | Contacting Conductivity Sensor, 0.5 Cell Constant, 3/4 inch NPT PVDF C |
| 3422B4A | Contacting Conductivity Analog Sensor, Cell Constant 0.5, 3/4 inch NPT |
| 3422B4B | Contacting, Conductivity Analog Sensor, Cell Constant 0.5, 3/4" NPT 3 |
| 3422B4D | Contacting, Conductivity Analog Sensor, Cell Constant 0.5, 3/4" NPT 31 |
| 3422B6A | Conductivity Sensor, Cell Constant 0.5, Stainless Steel-T, 20 ft Cable |
| 3422B6B | Conductivity Sensor, Cell Constant 0.5, Stainless Steel-T, Polypropyle |
| 3422B3C | Contacting, Conductivity Analog Sensor, Cell Constant 0.5, 3/4" NPT |
| 3422B3B | Contacting, Conductivity Analog Sensor, Cell Constant 0.5, 3/4" NPT PV |
资料下载
Recomendados similares
HACHConductivity Standard Solutions, 1000 µS/cm (491 mg/L NaCl)
Ver →
HACHPolymetron Conductivity Module for SC200 Ultra Pure Controller
Ver →
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
Ver →
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
Ver →
HACHConductivity Solution, 1000-2000 µS/cm, 1 L
Ver →
HACHConductivity Solution, 300,000-800,000 µS/cm, 1 L
Ver →
HACHCDW97-K10, Conductivity probe for salinity and brackish water
Ver →
A
HACHSolution, Conductivity Assembly
Ver →