A
Advanced HACH LDO™ Process Dissolved Oxygen Probe for seawaterDescontinuado
Break-through luminescent technology for dissolved oxygen. The HACH LDO® Dissolved Oxygen Probe continuously monitors DO with this revolutionary method of detection. It’s virtually maintenance-free wi
产品概述
Break-through luminescent technology for dissolved oxygen. The HACH LDO® Dissolved Oxygen Probe continuously monitors DO with this revolutionary method of detection. It’s virtually maintenance-free with no membranes to replace, no electrolyte solution to replenish, and no anode or cathode to clean or replace.
主要特点
- No Calibration for 1 Year:An internal standard calibrates the instrument with every reading. Factory calibration and membrane replacement are unnecessary. Periodic wiping of the sensor with a wet rag is all that is required for continuous measurement.
- No drift, 99% Accurate LDO Technology:The sensor is unaffected by pH swings, hydrogen sulfide, wastewater chemicals, heavy metals, or organic build-up on the sensor. Warm-up time is unnecessary so the analyzer can start measuring within 30 seconds of when it’s turned on.
- No Membranes, Simple Installation and Maintenance:The HACH LDO probe can be installed with a choice of pole or ball-float mounting kits. The probe has only one inexpensive replacement part—the sensor cap that is simple to replace. The sensor cap is warranted for one year. The probe is warranted for three years.
- Method of Detection:The HACH LDO sensor is coated with a luminescent material. Blue light from an LED is transmitted to the sensor surface. The blue light excites the luminescent material. As the material relaxes it emits red light. The time for the red light to be emitted is measured. Between the flashes of blue light, a red LED is flashed on the sensor and used as an internal reference. Increased oxygen in the sample decreases the time it takes for the red light to be emitted. The time measurements correlate to the oxygen concentration.
- Full Featured “Plug and Play” sc Digital Controllers:There’s no complicated wiring or set up procedures with the Hach sc100 controller. Just plug in any Hach digital sensor and it’s ready to use—it’s “plug and play.” One or two sensors—Use the sc100 Digital Controller to receive data from up to two Hach dig
技术参数
| 参数名称 | 说明 |
|---|---|
| Body material | Noryl |
| Cable Length | 10 m (33 ft) |
资料下载
- Prognosys For LDO sc: Eliminate last-minute maintenance emergencies
- Prognosys Para LDO sc : Elimine las emergencias de mantenimiento de última hora
- Prognosys pur LDO sc: Supprimez les opérations de maintenance imprévues!
- Prognosys Para LDO sc Elimine as emergências de manutenção de última hora
- Dissolved Oxygen, Direct Measurement, Method 10360
Recomendados similares
A
HACHReplacement Protector for Clark DO sensor
Ver →
HACHAcuerdo de servicio de laboratorio, LDO modelo 2, 1 servicio al año
Ver →
HACHOrbisphere 510 Ozone Controllers AC Power
Ver →
HACHOrbisphere M1100 Oxygen (LDO) Sensors
Ver →
HACHOrbisphere 510 Oxygen Controllers Panel Mount
Ver →
HACHOrbisphere 51x Nitrogen Controllers
Ver →
HACHOrbisphere 510, controlador O₂ (EC), CO₂ (TC), montaje en pared, 100-240 VAC, 0/4-20mA, presión externa
Ver →
HACHOrbisphere 3100 Portable Oxygen Analyzers
Ver →