Ultra low range turbidity measurement.

Filtertrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Complies with USEPA approved Hach Method 10133 for regulatory reporting and compliance monitoring. Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach's new SC200 or SC1000 Digital Controllers. Includes Manual and Stablcal Turbidity Standards.

The FT660 is passing the torch to the TU5400 sc. The last day to order the FT660 is July 27, 2018. See the recommended products section of this page or visit HachTU5.com to learn more.

主要特点

  • Lowest Limit of Detection in the Market:Using advanced laser optics and signal processing, the instrument detects increased concentrations of submicron-sized particles that are a precursor to larger particles. This allows for early filter deterioration detection that meets or exceeds that of particle counters all with the day-to-day convenience, simplicity, and reliability of a Hach turbidimeter. Operators can detect impending filter breakthrough, delineate filter ripening, and maximize effective filter run time. The Hach Filtertrak 660 sc Laser Nephelometer has the ability to detect a 0.3 mNTU or 0.0003 NTU change in turbidity, providing operators with confidence in their turbidity measurement.
  • Meets All USEPA Filter Monitoring Requirements:The Filtertrak sensor uses U.S. Environmental Protection Agency (USEPA) approved Hach Filtertrak Method #10133, the method specified in the USEPA LT2 draft guidance manual for compliance monitoring of membrane filters. The sensor meets all regulatory requirements for individual filter and combined effluent monitoring.
  • Monitor, Optimize, and Report:USEPA method compliance means that treatment plants with conventional or membrane filtration can monitor and optimize, as well as report, using this single technology.
  • Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers:The Filtertrak sensor can be used with any of Hach's sc Digital Controllers. Each sc controller accepts from two to eight sensors. Multiple controllers can be networked to accommodate many more sensors and parameters, reducing the cost per measuring point. Just plug in any Hach “plug and play digital sensor and it's ready to use without software configuration. “Plug and play connectivity means there's no complicated wiring or set up. The Filtertrak 660 sc Laser Nephelometer controller system now can manage multiple digital sensors.

技术参数

参数名称说明
Accuracy(Defined according to ISO 15839) From ±3% of reading or ±5 mNTU, whichever is greater
AlarmTwo nephelometric set-point alarms (SOM required)
Cable Length1.8m (5.9 feet)
Calibration MethodStablcal, stabilized formazin
CertificationsCE certified by Hach Company to EN61326 (industrial levels)
CertificationsListed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1
CommunicationMODBUS® RS485/ RS232, PROFIBUS DP, HART available with sc controller
ControllerSensor only
Dimensions (H x W x D)406 mm x 305 mm x 254 mm
Display Resolution0.001 mNTU up to 9.9999 mNTU
Fitting TypeDrenaje: Hembra de 1/2" NPT, lengüeta de manguera de 1/2" (suministrado), Drain: 1/2-inch NPT female, 1/2-inch hose barb (provided), clear drain tubing is recommended
Flow100 - 750 mL/min
Flow Rate100 - 750 mL / min (1.6 to 11.9 gal/hour)
Light SourceClass 1 laser product; with embedded 10 mW, 660 nm, Class 3B laser source (complies with 21 CFR 1040.10 and 1040.11. FDA Laser Accession No. 9911570)
Lower Limit of Detection (LOD)(Defined according to ISO 15839) Less than 0.3 mNTU
Lowest Expected Reading5 mNTU using deionized, reverse osmosis water, based on statistical averages from three instruments
Measurement FrequencyOne reading per second
Measuring PrincipleNephelometric light scatter at 90 degrees relative to incident monochromatic light beam
MountingWall and floor stand
Operating Humidity5 - 99 % non-condensing
Operating Temperature Range0 - 40 °C
Range(0.0 - 5.0 NTU) 5000 mNTU = 5.000 NTU
Repeatability(Defined according to ISO 15839) Better than ± 3.6 % at 30 mNTU (0.03 NTU)
Resolution0.01 mNTU from 10.00 - 99.99 mNTU
Resolution0.1 mNTU from 100.0 - 999.9 mNTU
Resolution1 mNTU from 1000 - 5000 mNTU
Sample Input0.25 " NPT female thread (1/4" compression fitting provided)
Sample Output0.5 " NPT female thread (1/2" hose barb provided) clear drain tubing is recommended
Sample Temperature0 - 50°C (32 - 122°F)
Signal Average TimeUser selectable from 0, 6, 30, 60, 90 seconds; default 90 seconds
Storage Conditions-20 °C to 60 °C
Warranty12 months
Weight4.54 kg
What's included?FT660sc, FT660sc User Manual, and 1000 mL 800 mNTU Stablcal ®.