产品概述
Simple to Integrate. Simple to Operate.
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your unique needs. Hach’s comprehensive approach saves you time on design, installation, training, maintenance, and operation. Our cationic conductivity system calculates accurate and reliable pH measurements even in the presence of contaminants such as chlorides, sulfates, nitrates and organic acids that commonly interfere with traditional pH probes.
主要特点
- Save time on design:A single design source and one product platform means you spend less time searching for design files or configuring components. Create and reuse your optimal design templates. Each sensor has a unique four-digit cell constant determined according to ISO 7888 and ASTM D 1125 standards.
- Accelerate your installation:One source, interchangeable components, a common user interface, and one support team make installation faster and less complicated. Quickly and easily transfer user settings between analyzers.
- Reduce training complexity:A single platform minimises time required to teach and learn product operations, getting new systems in use faster.
- Simplify maintenance and operation:Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. Low maintenance system is equipped with long-lasting resin which provides visual indication of exhaustion.
技术参数
| 参数名称 | 说明 |
|---|---|
| Operational Mode | Primary or secondary measurement, calculated value (dual channel only) or timer/scheduler |
| Accuracy | ± 1% of displayed value |
| Altitude | < 2000 m |
| Analog Output Functional Mode | Linear, Logarithmic, Bi-linear, PID |
| Analog Outputs | 0/4 - 20 mA isolated current outputs, max. 550 Ω, Accuracy: ±0.1% of FS (20 mA) at 25 °C, ±0.5% of FS over -20 °C - 60 °C range |
| Cell Constant k | 0.01 cm-1 |
| Communication | Five 4-20 mA Outputs, Modbus RS232/RS485, Profibus DPV1, Hart Communications |
| Communication Capabilities | Modbus RS232/RS485 |
| Conductivity Measurement Range | 0.01 - 200 µS/cm |
| Conduit Openings | 1/2" NPT Conduit |
| Display | Graphic dot matrix LCD with LED backlighting, transreflective |
| Display Resolution | 240 x 160 pixels |
| Display Size | 48 x 68 mm |
| Electrical Certifications | EMC CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Safety CAN/CSA C22.2 No. 61010-1 cETLus safety mark for: - General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1 |
| Enclosure Rating | IP66 / NEMA 4X |
| Flow | 83 - 333 mL/min (5 - 20 L/h) |
| Material Enclosures | Polycarbonate Aluminium (powder coated) Stainless Steel |
| Measurement Range 2 | 7 - 10.7 pH for Sodium Hydroxide |
| Measuring Range Conductivity | Specific Conductivity: 0.01 - 200 µS/cm |
| Measuring Range pH | 7 - 10 pH for Ammonia |
| Measuring Range pH 2 | 7 - 10.7 pH for Sodium Hydroxide |
| Measuring Range Resistivity | Specific Resistivity: 5 - 100000 kΩ x cm |
| Operating Temperature Range | 0 - 60 °C at 0 - 95 % RH (non-condensing) |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 - 240 VAC |
| Range | 7 - 10 pH for Ammonia |
| Relay Functions | Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning |
| Relays | Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A |
| Sample Input | 4 x 6 mm diameter tubing |
| Sample Output | 12 x 17 mm diameter tubing |
| Storage Conditions | -20 - 70 °C |
| Temperature Compensation | No, Automatic, and Manual |
| Temperature Compensation | No, Automatic, and Manual |
| Temperature Sensor | Pt100 Accuracy: < ± 0.2 °C |
| Warranty | 12 months |
| Weight | 15 kg |
| What's included? | Panel, Controller, Resin Cartridge, Conductivity Electrodes (2), Basic User Manual |
应用领域
Steam Cycle
同系列其他配置
| 型号 | |
|---|---|
| 9523.99.03P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH Ca |
| 9523.99.05P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH C |
| 9523.99.09P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH C |
| 9523.99.71P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH C |
| 9523.99.73P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH C |
| 9523.99.79P4 | Polymetron 9523 Specific and Cationic Conductivity Analyzer, and pH C |
资料下载
- Conductivity Monitoring with Hach Sensors for Critical Boilers
- Monitoring the Efficiency of Cation Exchangers
- Monitoring the Efficiency of Mixed Bed Ion Exchangers
- Monitoring Efficiency of Water/Steam Quality in Power Plants
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Complete Water Analysis Solutions for Power and Steam Generation
Recomendados similares
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
HACHConductivity Solution, 1000-2000 µS/cm, 1 L
HACHConductivity Solution, 2000-150,000 µS/cm, 1 L
HACHConductivity Solution, 200,000-300,000 µS/cm, 1 L
HACHConductivity Solution, 300,000-800,000 µS/cm, 1 L
HACH