9582sc Dissolved Oxygen Analyzers
Polymetron 9582 Dissolved Oxygen System with 4-20mA Output Communications, AC-DCDescontinuado
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your uniqu
产品概述
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your unique needs. Hach’s comprehensive approach saves you time on design, installation, training, maintenance, and operation.
主要特点
- Save Time on Design:A single design source and one product platform means you spend less time searching for design files or configuring components. Create and reuse your optimal design templates.
- Accelerate Your Installation:One source, interchangeable electronic components, a common user interface, and one support team make installation faster and less complicated. Quickly and easily transfer user settings between dissolved oxygen loops.
- Reduce Training Complexity:A single platform minimizes time required to teach and learn product operations, getting new systems in use faster.
- Simplify Maintenance and Operation:Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. Start-up and maintenance time are minimized with pre-mounted membrane cap and factory pre-conditioned sensors.
技术参数
| 参数名称 | 说明 |
|---|---|
| Operational Mode | Primary or secondary measurement, calculated value (dual channel only) or timer/scheduler |
| Cable Length | 10 m (33 ft) |
| Calibration Method | Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement |
| Communication | MODBUS RS232/RS485, PROFIBUS DPV1, HART optional |
| Communication Capabilities | 5x 4-20mA Out |
| Conduit Openings | 1/2" NPT Conduit |
| Connection Drain Line | 8 mm tubing |
| Connection Sample Line | 1/4" NPT thread (6mm or 1/4" tubing advised) |
| Display | Graphic dot matrix LCD with LED backlighting, transreflective |
| Display Resolution | 240 x 160 pixels |
| Display Size | 48 x 68 mm |
| Electrical Certifications | EMC CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Safety CAN/CSA C22.2 No. 61010-1 |
| Enclosure Rating | IP66 / NEMA 4X |
| Lower Limit of Detection (LOD) | < 1 ppb |
| Maintenance Interval | Membrane Lifetime: 6 months depending on sample |
| Manual Languages | Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish |
| Material | Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl |
| Material Enclosures | Polycarbonate Aluminium (powder coated) Stainless Steel |
| Measurements | 0 to 2000 ppb (0-2 ppm) |
| Operating Temperature Range | -20 - 60 °C at 0 - 95% RH (non-condensing) |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 - 240 VAC |
| Range | 0 - 2000 ppb (0-2 ppm) |
| Range | 0 - 2000 ppb |
| Relay Functions | Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning |
| Relays | Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A |
| Repeatability | ± 0.5 ppb or ±5%, whichever is greater |
| Reproducibility | ± 0.5 ppb or ± 2% whichever is greater |
| Response Time | For step change 1-40 ppb: <30s |
| Sample Flow Rate | 66 - 166 |
| Security Levels | 2 |
| Storage Conditions | -20 °C - 70 °C |
| Temperature Compensation | Automatic in the range of 0 - 45 °C (32 - 113 °F) |
| Temperature Compensation | Automatic in the range of 0 - 45 °C (32 - 113 °F) |
| Units | mg/L, ppm, µg/L, ppb, mbar, hPa, inch Hg, mmHg |
| Weight | 3.2 kg |
| What's included? | Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual |
同系列其他配置
| 型号 | |
|---|---|
| 9582.99.05P4 | Polymetron 9582 Dissolved Oxygen System with HART Communications, AC-D |
| 9582.99.75P4 | Polymetron 9582 Dissolved Oxygen System with HART Communications, 24 V |
| 9582.99.03P4 | Polymetron 9582 Dissolved Oxygen System with Profibus DP Communication |
| 9582.99.00P4 | Polymetron 9582 Dissolved Oxygen System, AC-DC |
| 9582.99.01P4 | Polymetron 9582 Dissolved Oxygen System with Modbus Communications, AC |
| 9582.99.70P4 | Polymetron 9582 Dissolved Oxygen System, 24 V DC |
| 9582.99.71P4 | Polymetron 9582 Dissolved Oxygen System with Modbus Communications, 24 |
| 9582.99.73P4 | Hach 9582sc Dissolved Oxygen System with Profibus DP Communications, 2 |
| 9582.99.79P4 | Polymetron 9582 Dissolved Oxygen System with 4-20mA Output Communicati |
资料下载
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Hach 9582sc Dissolved Oxygen Analyzer
- Hach 9582sc Dissolved Oxygen Analyzer
- Basic User Manual : Hach 9582sc Dissolved Oxygen Analyzer
- Basic User Manual : Hach 9582sc Dissolved Oxygen Analyzer
Recomendados similares
A
HACHReplacement Protector for Clark DO sensor
Ver →
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
Ver →
HACHField Service Partnership, 3100 LDO, 1 Service/Year
Ver →
HACHBench Service Partnership, 3100 LDO, 1 Service/Year
Ver →
HACHPocket Dissolved Oxygen (DO) Meter
Ver →
HACHField Service Partnership, 2586sc Oxygen Scavenger Analyzer, 2 Services/Year
Ver →
HACHCOD TNTplus Vial Tests, LR
Ver →
HACHHach BioTector B7000i TOC Analyzer
Ver →