产品概述
Chemical Oxygen Demand - Expert Ultra Low Range COD test made simple.
Recommended COD test for wastewater effluent. The Chemical Oxygen Demand analysis provides important information for the water treatment process and is essential to calculate the BOD COD ratio in wastewater. Due to this, the COD is one of the most frequently analyzed wastewater parameters globally. Why should you use Hach TNTplus® COD tests? Hach TNTplus COD vial test reagents are incredibly simple to use and cut down significantly on waste generation compared to other COD test kits. TNT820 is based on Hach Method 10211 for virtually any type of water sample. Hach TNTplus COD vial tests are available in multiple ranges. TNT820 provides a result in the Ultra Low Range of 1 - 60 mg/L COD and is often used for Chemical Oxygen Demand measurement in wastewater effluent. Hach TNT820 does not require a separate blanking vial for further waste reduction and is compatible with our ezCOD Waste Recycling Service for further peace of mind. Make the switch to TNTplus COD reagents today! Method For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion Method. Simply pipette in sample, digest, and read in your Hach Spectrophotometer. 25 tests per box. Recommended instruments DR3900 DR6000 DRB200 Benefits of Hach TNTplus COD test kits:
主要特点
- Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
- Automatic method detection:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
- Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.
技术参数
| 参数名称 | 说明 |
|---|---|
| Digestion Required | Yes |
| Instrument | DR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000 |
| Method Name | Reactor Digestion |
| Method Number | 10211 |
| Number of tests | 25 |
| Parameter | COD (Chemical Oxygen Demand) |
| Platform | TNT plus™ |
| Range | 1 - 60 mg/L COD |
| Truecal | Yes |
应用领域
Industrial Wastewater · Municipal Water
同系列其他配置
| 型号 | |
|---|---|
| TNT82006 | Chemical Oxygen Demand (COD) TNTplus Vial Test, ULR (1-60 mg/L COD), 1 |
资料下载
- TNTplus Vial Tests: Expert testing made simple
- Recognized Results Based on Quality Assurance and Quality Control
- How temperature affects measurement results
- TNTplus Brochure - Vietnamese
- TNTplus™ Brochure
- Pulp & Paper Industry Guide: Where, Why, What and How to Analyze
- Pulp & Paper Industry Guide: Dónde, por qué, qué y cómo analizar
- Pulp & Paper Industry Guide: Où, pourquoi, quoi et comment analyser
Recomendados similares
Replacement Protector for Clark DO sensor
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
HACHOrbisphere 510 Controller O₂ (EC), CO₂ (TC), Wall Mount, 100-240 VAC, 0/4-20mA, Ext. Press.
HACHOrbisphere 6110 Total O₂/CO₂ Package Analyzer & Installation Kit
HACHCarbon dioxide, dissolved oxygen, and pH test kit, model CA-10WR
HACHDissolved Oxygen AccuVac® Ampules, LR, pk/25
HACHField Service Partnership, 3100 LDO, 1 Service/Year
HACH