产品概述
IntelliCALⓇ ISECL181 is a digital, combination, Chloride ion selective electrode (ISE) with a with a non-refillable gel driTEK reference with a double junction, ceramic porous pin and porous PTFE annular ring, and built-in temperature sensor. The electrode measures Chloride concentration in water samples. The laboratory version of this ISE is shockproof with its Epoxy plastic body.The IntelliCAL ISECL181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications.
主要特点
- Requires virtually no maintenance:The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
- Fast, stable, and accurate results:IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
- Ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
- Can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±0.02 mV or 0.05%, whichever is greater |
| Cable Length | 1 m (3.28 ft) |
| Electrode Type | Non-Refillable Dritek Gel Reference Element |
| ISA Required | Chloride ISA (#2318069) |
| Junction | Double Junction (ceramic Porous Pin and annular porous PTFE) |
| Kit? | No |
| Length | 175 mm (6.89 in.) |
| Method Type | Laboratory: Non-Refillable Dritek Gel Reference Element |
| Parameter | Chloride |
| Probe Type | Standard |
| Product Kit | Model: ISECL181 Accessories Included: None |
| Range | 0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻ |
| Reference Type | Ag/AgCl |
| Resolution | Selectable up to 4 significant digits |
| Sample depth | 25.4 mm (1 in.) |
| Sample Volume | 25 mL |
| Sensor material | Epoxy |
| Sensor Type | Solid-state crystal membrane |
| Special Features | Dry storage & fast response time. No replacement membranes. |
| Temperature Accuracy | ±0.3 °C (±0.54 °F) |
| Temperature Range | 5 - 50 °C (41 - 122 °F) |
| Temperature Resolution | 0.1 °C (0.18 °F) |
| Test requirements | Parameter Needed: Chloride Minimum Sample Depth (mm): 26 |
| Thermistor | ATC |
| Warranty | 12 months |
| Weight | 0.1 kg |
| What's included? | IntelliCAL ISECL181 combination Chloride ISE, 1 m cable (ISECL18101), Test certificate, and Basic User Manual. |
应用领域
Municipal Water · Potable Water · Production Water · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| ISENH418101 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 1 |
| ISENH418103 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 3 |
| ISENO318101 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 1 m |
| ISENO318103 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 3 m |
| ISENH4181AP | IntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) w |
| ISENO3181AP | IntelliCAL ISENO318101 Nitrate (NO₃⁻) Ion Selective Electrode (ISE) wi |
| ISENA38103 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 3 m ca |
| ISENA38101 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 1 m ca |
| ISENH318103 | IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 3 m |
| ISENH318101 | IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m |
| ISECL18103 | IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m |
| ISEF12103 | IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 3 m ca |
| ISEF12101 | IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 1 m ca |
| ISENH3181AP | IntelliCAL ISENH318101 Ammonia (NH₃) Ion Selective Electrode (ISE) wit |
| ISECL181AP | IntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) wit |
| ISEF121AP | IntelliCAL ISEF12101 Fluoride (F⁻) Ion Selective Electrode (ISE) with |
| ISENA381AP | IntelliCAL ISENA38101 Sodium (Na⁺) Ion Selective Electrode (ISE) with |
资料下载
- Brine Analysis Package
- Introduction to Ion-Selective Measurement
- Electrochemistry Theory and Practice
- Complete Water Analysis for the UPSTREAM OIL & GAS INDUSTRY
- Measuring High Range Chloride Using the Chloride IntelliCAL
- Simplified High Range Chloride Measurement in Hydraulic Fracturing Applications Using Hach IntelliCAL™ Chloride ISE
- Introduction to Hach Services
- A melhor solução para resultados precisos em todas as aplicações
Recomendados similares
HACHDigestor (digestor rápido de COD)
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHSerie de tiras reactivas para análisis de agua
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHEspecial Servicio / Otros TSS
HACH