Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

LPV431.99.00002

LPV431.99.00002
Surface Scatter® 7 sc (SS7 sc) Sensor Assembly (Instrument Only)
HACH LPV431.99.00002
Outstanding results in high temperatures: Surface Scatter 7 sc

产品概述

Outstanding results in high temperatures: Surface Scatter 7 sc

Able to measure very high and low turbidity levels accurately, this turbidimeter is uniquely designed so that the light source and the photocells never come in contact with the sample. The sample is introduced into the center sample tube of an inclined turbidimeter body at a flow rate of 1 - 2 liters per minute. As the fluid spills over the top of the turbidimeter body, a stable, flat surface of liquid forms and becomes the measuring surface. The light source emits a high-intensity beam of light, which strikes the surface of the fluid diagonally. The detector registers the light that is scattered at 90° to the incident beam. This scattered light is proportional to the content of suspended particles in the sample.

主要特点

  • Less fouling for easy maintenance:The Hach Surface Scatter 7 sc Turbidimeter (SS7) is uniquely designed so that the light source and photocell never come in contact with the sample. In fluids with high loads of suspended solids this makes sample cell cleaning and replacement unnecessary.
  • Built to Last:All wetted parts of the Hach SS7 turbidimeter are made with corrosion-resistant materials for extended life. The photo-detector and light source assemblies are protected from the effects of corrosive vapors and heated samples. The SS7 turbidimeter is warranted against defects in materials or workmanship for two years from the date of shipment.
  • Wide Measurement Range:The SS7 turbidimeter can reliably measure turbidity from 0.01 to 9999.9 NTU in samples that vary from clear water to corrosive and high temperature paper mill and oil field samples.

技术参数

参数名称说明
Accuracy±5% of reading or ±0.1 NTU (whichever is greater) from 0 - 2000 NTU
Accuracy 2±10% of reading from 2000 - 9999 NTU
AlarmRelays can be programmed through sc controller for warning, alarm, feeder, event, pulse width modulation, and frequency control.
Ambient Temperature0 - 50 °C
ChannelsInstrument Only
ControllerNo
Controller CompatibilitySC4500, SC1000, SC200
Enclosure ConstructionPlastic instrument enclosure
Enclosure RatingNEMA 12
Installation CategoryCategory II
MountingWall mount
Power Requirements (Voltage)100/230 VAC
Range0.01 - 9999.9 NTU
Relative Humidity5 - 95% non-condensing
Repeatability1.0% or ±0.04 NTU, whichever is greater
Resolution<1000 NTU: 0.01 NTU 1000 - 9999.9 NTU: 0.1 NTU
Response TimeInitial response in 45 seconds
Sample Flow RateSample flow required 1.0 - 2.0 L/min
Sample Input0.75 " NPT female thread
Sample Output1 " NPT female thread
Sample Temperature0 - 50 °C
Storage Conditions-20 - 80 °C
Warranty24 months
Weight15.8 kg (34.8 lb)
What's included?SS7®sc, Wall Mount Kit, Cylinder Brush, Light Source Alignment Template, 0.75 x 0.75 inch NPT Nipple, Calibration Cup, 0.75 inch NPT Ball Valve, SS7sc User Manual, and 500 mL 4000 NTU Formazin Standard.