产品概述
The next standard in the evolution of turbidity
The platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test. For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection® Technology in both, lab and process, instruments. The TU5 Series® dramatically reduces the time needed to get a turbidity measurement you can rely on. The TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of your sample meaning you no longer have to apply silicone oil to your vial and index to ensure an accurate reading. In addition, you can have confidence that you will get consistent results in the lab, from operator to operator, since the impact of small interferences is minimized due to the collection of light at 360°. Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.
主要特点
- Groundbreaking 360° x 90° Detection Technology:The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
- Matching lab and online results:For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.
- Everything about turbidity – faster:The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±2% plus 0.01 NTU from 0 - 40 NTU; ±10% of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C) |
| Calibration Method | For Formazin and Stablcal: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations Degrees 0 - 100 mg/L SDVB 0 - 1000 NTU |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) Australian ACMA Marking |
| Communication | Link2sc |
| Dimensions (H x W x D) | 195 mm x 409 mm x 278 mm |
| Display | 7" WVGA (800 x 480) color TFT-LCD with touch screen |
| Enclosure Construction | PC/ABS Blend Plastic |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Model | TU5200 ISO |
| Operating Humidity | 80% at 30 °C (non condensing) |
| Operating Temperature Range | 10 - 40 °C (50 - 104 °F) |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 - 240 VAC |
| Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 250 EBC |
| Regulatory | DIN EN ISO 7027 |
| Repeatability | <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater >40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F) |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L |
| Response Time | Signal averaging off: 7 seconds Signal averaging on: 10 seconds (when averaging time is 5 seconds) |
| Sample Temperature | 4 - 70 °C (39 - 158 °F) |
| Source Lamp | ISO Version - 850 nm Class 2 Laser |
| Storage Conditions | -30 - 60 °C (-22 - 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC; mg/L if calibrated with Degrees calibration curve |
| Warranty | 12 months |
| Weight | 2.4 kg (5.29 lbs.) |
| What's included? | TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand |
应用领域
Filtration · Groundwater · Municipal Water · QA/QC Lab · Surface Water · Water Supply Conditioning
同系列其他配置
| 型号 | |
|---|---|
| LPV442.99.01012 | TU5 Series® TU5200 Laboratory Laser Turbidimeter without RFID, EPA Ver |
| LPV442.99.03012 | TU5 Series® TU5200 Laboratory Laser Turbidimeter with RFID, EPA Versio |
| LPV442.99.03022 | TU5 Series® TU5200 Laboratory Laser Turbidimeter with RFID, ISO Versio |
资料下载
- Nova tecnologia de medição de turbidez em água – a Experiência para UE
- New Water Turbidity Measurement Technology - the US Experience
- Measuring Turbidity and Suspended Solids in Power Plants
- Lab Standards : Stay compliant with your turbidity reading using Stablcal Sealed Vials
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Rimanete conformi alle vostre letture di torbidità utilizzando gli standard in cuvette sigillate Stablcal
Recomendados similares
HACHDigestor (digestor rápido de COD)
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHSerie de tiras reactivas para análisis de agua
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHEspecial Servicio / Otros TSS
HACH