Industries
Pharmaceutical, power, CDC, water utilities, and other industries
Target Customers
Pharmaceutical company QC laboratories, drug R&D, drug testing institutes, power plants, CDC laboratories, third-party testing organizations, universities and research institutes, etc.
Instrument Features
Excellent Repeatability
-
Reduces interference between measurements of different samples
-
Consistent results with excellent repeatability
-
Reliable Measurement Assurance
-
Multiple sensors continuously monitor the instrument's health status
-
Self-check at startup and on-demand diagnostics are both reported
-
Over-range recovery function when samples exceed the measuring range
-
Simple and Easy Operation and Maintenance
-
10.4-inch color touchscreen with a more intuitive user interface
-
Wizard-based software interface makes instrument operation simpler and easier
-
The instrument's built-in automatic measuring range adjustment/dilution function allows users to complete measurements without knowing the sample concentration in advance
-
Only one reagent is needed to complete the corresponding measurement and analysis (self-prepared or purchased from Hach)
-
Simple and convenient paperless function, capable of exporting data to network shared directories managed by Windows security policies
Low Cost of Ownership
-
Low reagent cost
-
No frequent maintenance required, once a year is sufficient
-
No need for a separate computer
-
Fast Calibration Saves Time
-
Calibration takes only 2 hours!
-
Built-in automatic system suitability test for USP and EP, and SDBS verification procedure for JP
-
Compliance with Pharmacopoeias and Regulations
-
Complies with major global pharmacopoeias, including: USP, JP, EP, IP, KP, ICH
-
Simplified IQ / OQ / PQ qualification procedures comply with ICH guidelines
-
Simple automated workflows applicable to the following areas:
-
USP/EP SST bulk water
-
USP SST sterile water
-
JP SDBS verification
-
KHP calibration compliant with JP standards
Technical Specifications
-
Performance Specifications
-
Measuring range 0 ~ 100 ppm
-
Precision <2% or 3ppb (whichever is greater)
-
Accuracy ± 3% (≥500ppb)
-
Calibration interval Approx. 2 hours
-
Analysis time Fastest approx. 4.5 minutes
-
Inorganic Carbon Treatment
-
Do samples with high inorganic carbon content require an additional inorganic carbon removal module? No
-
Is dynamic endpoint detection used to ensure complete removal of inorganic carbon? Yes
-
System self-diagnostics to ensure data integrity
-
Will the instrument report a TOC value under the following conditions?
-
UV lamp intensity too low No
-
Insufficient carrier gas/tank empty No
-
Insufficient reagent/bottle empty No
-
Insufficient sample volume/vial empty No
Reagent
-
Reagent supply Purchase or self-prepare
-
Option to prepare reagent yourself Yes
-
Total number of reagents (acid, oxidant, dilution water) One
-
Measurement Method and Assurance
-
Oxidation UV (ultraviolet) lamp + persulfate
-
UV lamp confirmation Broadband silicon photodiode sensor
-
Detector Digital NDIR
-
Detector stability Continuously verified against reference values
-
Detector moisture pre-removal Peltier cooler with continuous current monitoring
-
Dispenser module Syringe pump, accurate to +/-1% of volume
-
Flow sensor Dynamic fluid sensor (ensures sample and reagent volume accuracy)
-
Carrier gas selection High-purity air, oxygen, or nitrogen
-
Carrier gas pressure confirmation Dual-orifice pressure sensor
-
Carrier gas valve shutoff Valve closes after measurement is complete to avoid gas waste
-
Auto-range function Yes
-
Analysis mode NPOC (Non-Purgeable Organic Carbon)
-
Data storage and retrieval
-
Regulatory compliance 21 CFR Part 11, all measurement results recorded to an encrypted database
-
Paperless reporting Report output via Ethernet to network shared directories managed by Windows security policies
-
IO (Input/Output) 3 USB ports, 1 Ethernet port
-
Data export format PDF, CSV
User Interface
-
Display 10.4-inch high-resolution color touchscreen
-
External PC No external hardware required, embedded Windows 10 IoT Enterprise operating system
-
External keyboard/mouse Optional, not required
-
Ease of operation Intuitive user interface with measurement setup that guides the operator through the process
Technical Procedures
-
Calibration Automated workflow: 18-point calibration with KHP (5 concentrations, each repeated 3 times, 3 backgrounds)
-
Calibration solution 5ppm C KHP (single 125 mL bottle), diluted with reagent to concentrations of 1, 2, 3, 4, 5ppm
-
Verification test/system suitability Automated workflow:
-
● USP SST bulk water
-
Blank, 500ppb as C: sucrose, p-benzoquinone
-
● USP SST sterile water
-
Blank, 8ppm as C: sucrose, p-benzoquinone
-
● JP-16<2.59> verification
-
Blank, 500ppb as C SDBS
Regulatory Compliance
-
USP<643> (including sterile water SST), JP-16<2.59>, EP<2.2.44>, IP, CP, KP, US EPA 5310c Yes
-
21 CFR Part 11 Yes
-
ICH guidelines for instrument qualification, including:
-
Accuracy, precision, detection limit, quantitation limit, linearity, range, specificity, robustness Yes
Autosampler
-
Capacity 64 sample vials (40mL glass vials TOC)
-
Style XYZ, septum piercing
-
Sample tray material Anodized aluminum
General Technical Data
-
Instrument dimensions W320 x D507 x H410 mm
-
Power supply 100-240 VAC, 50/60 Hz, 2A
-
Weight 14 kg (31 lbs)
-
Autosampler dimensions W366 x D537 x H457 mm
-
Power supply 100-240 VAC, 47-63Hz
-
Weight 21 kg (45 lbs)
-
Operating temperature and humidity 5-35℃; relative humidity up to 90%, non-condensing
-
Reporting units ug/L (ppb)
Accessories Information
-
Order No. Description
-
Consumables and Spare Parts
-
9459400 Concentrated reagent, QbD1200+
-
9459500 5 ppm C KHP calibration solution, 125ml
-
9459600 SDBS verification kit, 500 ppb C
-
9459700 USP system suitability kit (500 ppb)
-
9459800 USP system suitability kit (8 ppm)
-
9459900 Characterization test kit (1 ppm)
-
9460000 Stability test kit
-
9460100 Verification protocol kit
-
9891700 Syringe replacement kit
-
9890500 Ozone processor replacement kit
-
9898900 Tubing replacement kit
-
9880200 UV reactor replacement kit
-
9890600 Reagent bottle kit with custom caps
-
9898300 QBD1200+ power adapter
-
9467200 AS 0640 autosampler tray
-
9454400 AS 0640 autosampler flangeless nut removal tool
-
9467400 AS 0640 autosampler needle sleeve
-
SP6790 AS 0640 autosampler septum piercing probe
-
2672700 Vials with septa, 40 mL, TOC, 72 pcs
Hach Service Products
-
SP-QLF1-QBD QBD1200+ instrument qualification service (IQ/OQ)
-
SP-COMF1-QBD QBD1200+ installation and commissioning service
Ordering Information
Order No. Description
Analyzer
-
9880000 QbD1200+ laboratory TOC analyzer
-
9890400 AS-0640 autosampler (64 sample positions)
-
QbD1200+ laboratory TOC analyzer & autosampler
-
Source: Hach Water Quality website public information
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Hach-Lab: caso de aplicación
Resumen del proyecto
La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hach-Lab en la planta existente, con el objetivo de análisis de agua colorimétrico y volumétrico en laboratorio.
Retos técnicos
Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hach-Lab deba incluir selección por método, volumen de muestras y kit de reactivos.
Configuración
El suministro y la instalación se organizaron por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. En planta esto supuso selección por método, volumen de muestras y kit de reactivos; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.
Comportamiento
Tras la puesta en marcha el resultado es métodos normalizados que hacen comparables los datos entre laboratorios, y las lecturas se usan ya para ajustar el proceso.
Alimentación y Bebidas — Hach-Lab: caso de aplicación
Situación en planta
Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis de agua colorimétrico y volumétrico en laboratorio.
El problema
La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por método, volumen de muestras y kit de reactivos.
Qué hicimos
Adoptamos un enfoque de laboratorio: configurar según métodos de laboratorio y volumen de muestras. La entrega se construyó en torno a selección por método, volumen de muestras y kit de reactivos; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultado operativo
En servicio el sistema responde a lo previsto: métodos normalizados que hacen comparables los datos entre laboratorios, con un mantenimiento rutinario notablemente menor.
Química y Farmacéutica — Hach-Lab: caso de aplicación
Contexto de aplicación
reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hach-Lab, centrándose en análisis de agua colorimétrico y volumétrico en laboratorio.
Limitaciones del proceso
la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hach-Lab debe cubrir selección por método, volumen de muestras y kit de reactivos.
Enfoque de suministro
La entrega se gestionó como laboratorio: configurar según métodos de laboratorio y volumen de muestras. La ejecución se centró en selección por método, volumen de muestras y kit de reactivos, junto con certificación Ex y trazabilidad de datos según GMP.
Resultados en campo
La operación evidencia el beneficio: métodos normalizados que hacen comparables los datos entre laboratorios, con una confianza claramente mayor en este punto de medición.
Energía y Electricidad — Hach-Lab: caso de aplicación
Perfil del cliente
El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hach-Lab; el foco es análisis de agua colorimétrico y volumétrico en laboratorio.
Dificultades clave
Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por método, volumen de muestras y kit de reactivos.
Implementación
El alcance se canalizó por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. Técnicamente se apoya en selección por método, volumen de muestras y kit de reactivos, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Beneficio para el cliente
En la práctica esto significa métodos normalizados que hacen comparables los datos entre laboratorios, lo que redujo la carga del equipo de mantenimiento.
Recomendados similares
HACHDigestor (digestor rápido de COD)
HACHSerie de tiras reactivas para análisis de agua
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHValorador potenciométrico automático serie 1000
HACH