产品概述
Expert Low Range Phosphorus test made simple.
Phosphorus TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, every time. For determination of Reactive (ortho) and Total Phosphorus (phosphate) in wastewater, drinking water, boiler water, surface water and process water. TNTplus® phosphorus reagents can provide an Orthophosphate or Total Phosphorus result. Ascorbic Acid Method is Equivalent to EPA 365.1. Phosphorus TNTplus chemistry allows you to test for reactive or total phosphorus with each vial. Follow the easy to navigate procedure printed on the lid of the box and then insert the TNTplus vial into your Hach spectrophotometer for an immediate result. Measurments are reported in the low range of 0.15 - 4.50 mg/L as PO4. If you are required to digest your phosphorus sample, performing this step in the sealed vial eliminates loss to evaporation and allows up to 30 simultaneous digestions depending on which DRB200 Reactor Block you are using. Phosphates present in organic and condensed inorganic forms (meta-, pyro- or other polyphosphates) are first converted to reactive orthophosphate in the total phosphorus procedure. Treatment of the sample with acid and heat provides the conditions for hydrolysis of the condensed inorganic forms. Organic phosphates are also converted to orthophosphates in the total phosphorus procedure by heating with acid and persulfate. The reactive phosphorus procedure measures only the reactive (ortho) phosphorus present in the sample.
主要特点
- Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
- Automatic method detection:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
- Documented shelf life and COA:The 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.
技术参数
| 参数名称 | 说明 |
|---|---|
| According to standard | EPA 365.1 |
| Digestion Required | Yes for Total |
| EPA compliant | Yes |
| Instrument | DR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000 |
| Method Name | Ascorbic Acid |
| Method Number | 10209 |
| Number of tests | 25 |
| Parameter | Phosphorus, Acid Hydrolyzable Phosphorus, Reactive (Ortho) Phosphorus, Total |
| Platform | TNT plus™ |
| Range | 0.05 - 1.5 mg/L PO₄-P; 0.15 - 4.5 mg/L PO₄ |
| Sample Requirements | The pH of the water sample must be between pH 2 - 10. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F). |
| Truecal | Yes |
应用领域
Boiler Water · Cooling Water · Discharge · Groundwater · Industrial Wastewater · Influent for Wastewater · Municipal Water · Nutrient Monitoring · Pre-Treatment · Primary Treatment · Source Water
同系列其他配置
| 型号 | |
|---|---|
| TNT846 | Phosphorus (Reactive) TNTplus Vial Test (5-90 mg/L PO₄), 25 Tests |
| TNT844 | Phosphorus (Reactive and Total) TNTplus Vial Test, HR (1.5-15.0 mg/L P |
| TNT845 | Phosphorus (Reactive and Total) TNTplus Vial Test, UHR (6-60 mg/L PO₄) |
资料下载
- TNTplus Vial Tests: Expert testing made simple
- Recognized Results Based on Quality Assurance and Quality Control
- Understanding the Different Phosphorus Tests
- How temperature affects measurement results
- Ultra Low Range Total and Reactive Phosphorus for use with DR 2700, DR 2800, DR 3800, DR 3900 and DR 5000 Hach Spectrophotometers
- TNTplus Brochure - Vietnamese
- Complete Water and Product Quality Analysis: Beverage Industry
- TNTplus™ Brochure
Recomendados similares
HACHPhosphoric Acid Solution, 1.0 Molar 5 Gallon
HACHAmino acid reagent powder pillows for LR silica, 25 mL, pk/1000
Nutrients Basic Reagent Set, TNTplus
HACHRapid Silver Reagent Powder Pillows, pk/100
HACHRochelle Salt-PVA Reagent, 500 mL
HACHToluene, 4 L
HACHSodium carbonate solution, 500 mL
HACH