TNT875
Familia de producto: Surfactants TNTplus Vial Tests
Nonionic Surfactants TNTplus Vial Test, LR (0.2-6.0 mg/L as Triton X-100), 25 Tests
HACH TNT875
Expert Low Range Nonionic Surfactants test made simple.

产品概述

Expert Low Range Nonionic Surfactants test made simple.

Nonionic Surfactants TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For determination of lower concentrations of Nonionic Surfactants by the TBPE method, calibrated with Triton X-100. Traditional surfactants measurement has often involved time consuming handling steps, requiring expensive high end instrumentation or the use of large amounts of toxic chemistries. With Surfactants TNTplus reagents, simply add sample and included reagents to the vial, shake the vial for a defined period of time and insert into your Hach spectrophotometer! The Direct Read Technology will provide your Surfactants results in mg/L! No more cleaning glassware, dealing with large amounts of toxic waste, and worrying about human errors. Upgrade from traditional Surfactants methods to TNTplus Surfactants reagents today! 25 Nonionic Surfactants vials per box.

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
  • Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.

技术参数

参数名称说明
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NameTBPE
Method Number10275
Number of tests25
ParameterSurfactants, Nonionic
PlatformTNT plus™
Range0.2 - 6.0 mg/L as Triton x 100
Sample RequirementsThe pH of the water sample must be between pH 4 - 9. The temperature of the water sample and reagents must be between 20 - 23 °C (68 - 73.4 °F).
Storage Conditions15 - 25 °C

应用领域

Industrial Wastewater · Municipal Water · Surface Water

同系列其他配置

型号
TNT885Cationic Surfactants TNTplus Vial Test (0.2 - 2.0 mg/L), 25 Tests
TNT876Nonionic Surfactants TNTplus Vial Test, HR (6.0-200 mg/L as Triton X-
TNT874Anionic Surfactants TNTplus Vial Test (0.1-4.0 mg/L), 25 Tests