Total Nitrogen & s-TKN TNTplus Vial Tests
Total Nitrogen & s-TKN TNTplus Vial Tests
产品概述
Expert Low Range Nitrogen test made simple.
Nitrogen TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. Hach Method 10208 determines Total Nitrogen in water and wastewater by the Persulfate Digestion Method with a range up to 16 mg/L N. Digestion occurs within the sealed vial which eliminates evaporation and nitrogen loss due to splatter.
主要特点
- Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
- Automatic method detection:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
- Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.
技术参数
| 参数名称 | 说明 |
|---|---|
| Digestion Required | Yes |
| Instrument | DR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000 |
| Method Name | Persulfate Digestion |
| Method Number | 10208 |
| Number of tests | 25 |
| Parameter | Nitrogen, Total |
| Platform | TNT plus™ |
| Range | 1 - 16 mg/L N |
| Sample Requirements | The pH of the water sample must be between pH 3 - 12. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F). |
| Truecal | Yes |
同系列其他配置
| 型号 | |
|---|---|
| TNT880 | Simplified TKN (s-TKN) TNTplus Vial Test (0-16 mg/L N), 25 Tests |
| TNT827 | Nitrogen (Total) TNTplus Vial Test, HR (5-40 mg/L N), 25 Tests |
| TNT828 | Nitrogen (Total) TNTplus Vial Test, UHR (20-100 mg/L N), 25 Tests |
| TNT818 | Nitrogen (Total) TNTplus Vial Test, UHR (100-250 mg/L N), 25 Tests |
资料下载
- TNTplus Vial Tests: Expert testing made simple
- Recognized Results Based on Quality Assurance and Quality Control
- How temperature affects measurement results
- TNTplus Brochure - Vietnamese
- Complete Water and Product Quality Analysis: Beverage Industry
- TNTplus™ Brochure
- Pulp & Paper Industry Guide: Where, Why, What and How to Analyze
- Pulp & Paper Industry Guide: Dónde, por qué, qué y cómo analizar
Recomendados similares
HACHPhosphoric Acid Solution, 1.0 Molar 5 Gallon
Ver →
HACHAmino acid reagent powder pillows for LR silica, 25 mL, pk/1000
Ver →
A
HACHNutrients Basic Reagent Set, TNTplus
Ver →
HACHRochelle Salt-PVA Reagent, 500 mL
Ver →
HACHToluene, 4 L
Ver →
HACHSodium carbonate solution, 500 mL
Ver →
HACHPhosphate Reagent Set
Ver →
HACHRapid Silver Reagent Powder Pillows, pk/100
Ver →