产品概述
The turbidity bypass sensor that brings clarity
Turbidities in the range of FNU (NTU) 0.0001-1,000 are measured and displayed alphanumerically using a controller. This high resolution facilitates precision differentiation, even for ultra clear liquids. A pulsed, long-life IR radiation source (LED) ensures that costs are minimized. Designed in accordance with DIN EN ISO 7027 and permanently calibrated before leaving the factory. All key data is set to practical standard values. The instruments are immediately ready for use after connection to the power supply and the supply of sample water. The measuring range and all data outputs are modified to suit requirements using menus on the controller. All optical and electronic assemblies are installed in housings that are physically very strong and proof against water jets.
主要特点
- Large measuring range: 0.0001 - 1,000 FNU:The Hach Ultraturb Seawater sc sensor measures turbidity from 0.0001 to 1000 FNU (NTU) for a wide variety of low to medium range turbidity applications. Use it to effectively monitor conventional filtered water processes, effluent water, distribution systems, and elevated tanks where small-sized particulates or air entrapment may be an issue.
- Self-cleaning Sample Chamber:The Ultraturb Seawater sc sensor is available with an automatically self-cleaning sample chamber that guarantees stable measured values. The silicon wiper blades inside the sample chamber are held in place with a magnetic coupling wheel to further keep the sample chamber intact.
- Suitable for seawater, brackish water, raw water and other applications:The Ultraturb Seawater sc sensor is resistant to salt concentrations up to 65 g/L.
- Ratio Methodology Detects Sample Chamber Fouling:The Ultraturb Seawater sc sensor uses ratio methodology with detection at 90° and 180° to minimize reflections in the measuring cell and on the windows. In this way, fouling of the sample chamber is detected earlier than with a single detection system. The Hach Ultraturb Seawater sc sensor meets the ISO 7027 turbidity requirements for on-line process turbidity.
- Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controller:The Ultraturb Seawater sc sensor can be used with Hach’s Digital SC Controllers. The SC4500 controller accepts up to two sensors and the SC1000 accepts up to eight sensors. Multiple controllers can be networked to accommodate many more sensors and parameters, reducing the cost per measuring point. Just plug in any Hach “plug and play” digital sensor and it’s ready to use without software configuration. “Plug and play” connectivity means there’s no complicated wiring or set up. Network the Ultraturb Seawater sc sensor with any of Hach’s digital sensors for measuring dissolved oxygen, ORP, conductivity, and many other parameters.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ± 0.008 FNU ±1% of reading whichever is greater (0 - 10 FNU) |
| Automatic Wiper | Yes |
| Cable Length | 5 m |
| Calibration Method | Stablcal |
| Controller Compatibility | SC4500, SC1000, SC200 |
| Dimensions (H x W x D) | 240 mm x 250 mm x 110 mm |
| Display | Display provided through connection with Hach sc Controller |
| Enclosure Rating | IP55 |
| Inlet | 13 mm ID Tubing or fixed connection (PVC system component pipework) |
| Material | Housing: ASA; Window: Quartz; Wiper Blade: Silicon; Wiper Shaft: stainless steel 1.4571; Wiperarm: titanium alloy |
| Measurement Method | 90° infrared pulse scattered light technique in accordance with EN ISO 7027-1:2016 |
| Model | Ultraturb seawater sc |
| Operating Temperature Range | 2 - 40 °C (36 - 104 °F) |
| Outlet | 13 mm ID Tubing or fixed connection (PVC system component pipework) |
| Pressure Range | 6 bar at 20 °C (87 psi at 68 °F) |
| Range | 0.0001 - 1000 FNU (TE/F, NTU, FNU) can be programmed as required (0.001-250 EBC = 2500 ppm SiO2) (Note: 1 FNU is equivalent to 1 NTU) |
| Repeatability | ± 0.003 FNU or ± 0.5% of reading (whichever is greater) from 0 - 2 FNU |
| Resolution | 0.0001 - 0.9999 / 1.000 - 9.999 / 10.00 - 99.99 / 100 - 1000 FNU (NTU) |
| Response Time | 1 - 60 s (programmable) |
| Sample Flow Rate | 0.2 - 1 L/min |
| Sample Temperature | Max. 50 °C (122 °F) |
| Sensor cleaning | Wiper, automatic |
| Verification | Stablcal |
| Warranty | 12 months |
| Weight | Approx. 1.5 kg (3.3 lbs.) |
| What's included? | Hach Ultraturb sc, Factory Test Certificate, 4 wipers, Accessory set LZP816, User Manual. |
同系列其他配置
| 型号 | |
|---|---|
| LPV415.99.12002 | Ultraturb Seawater sc with 0.35 m cable |
| LPV415.99.32002 | Ultraturb Seawater sc with 10 m Cable |
| LPV415.99.82002 | Ultraturb Seawater sc with 1 m Cable |
资料下载
- Ολοκληρωµένη λύση παρακολούθησης της ποιότητας του νερού σε µια εγκατάσταση αφαλάτωσης
- Turnkey Water Quality Monitoring Solution for a Desalination Facility
- Soluzione chiavi in mano per il monitoraggio della qualità dell’acqua in un impianto di desalinizzazione
- Solución llave en mano para el control de la calidad del agua en una planta desaladora
- Schlüsselfertige Lösung zur Überwachung der Wasserqualität einer Entsalzungsanlage
- Solution clé en main de contrôle de la qualité de l’eau pour une installation de dessalement
- Desalinasyon Tesisi için Anahtar Teslim Su Kalitesi İzleme Çözümü
- Article: BWM Indicative Measurement
Recomendados similares
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
Accu4 Spare Chamber with Plumbing, High Pressure
HACH