0755-82221901 sales@ainstru.com

HI1043B

HI1043B

Electrodo de pH rellenable de doble unión para alta temperatura

Electrodo de pH de doble unión rellenable con conector BNC
  • HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass.

  • This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.

  • Refillable electrode

  • Double junction design

  • High temperature glass

  • Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of connector, reference type, and the electrolyte used are just some of the design considerations.

  • The HI1043B uses high temperature (HT) glass, spherical bulb, glass body, single ceramic frit, double junction and is refillable with 3.5M KCl.

Figure 1 Details:

High Temperature Glass Formulation Measuring pH at very high temperatures is harmful to the sensitive glass bulb and will shorten its life. A pH electrode with general purpose (GP) glass has a resistance of 100 megohms at 25°C, while HT glass has a resistance of about 400 megohms at 25°C. When the HI1043B is used at high temperatures, the resistance decreases and approaches that of GP glass. The HI1043B is suitable for samples from 0 to 100°C.

Figure 2 Details:

  • Spherical Bulb

  • The spherical bulb is for general purpose use. Other tip shapes include conical for penetration and flat tip for surface measurements.

Figure 3 Details:

  • Glass Body

  • The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the more stable the reference potential.

Figure 4 Details:

  • Single Ceramic Double Junction Reference

  • The HI1043B is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction, also known as a salt bridge, is a necessary component of the electrical circuit. The movement of ions must flow through the junction for a stable reading. The outer reference has a single ceramic frit. Ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

Figure 5 Details:

  • Refillable

  • The HI1043B is a refillable probe. Since it is a double junction pH electrode, the fill solution is HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrodes. The absence of silver will prevent any silver precipitate from forming and clogging the junction. Clogging of the junction will result in drift and unstable readings.

Figure 6 Details:

  • BNC Connector

  • The HI1043B has a BNC connector. This type of connector is universal in that it can be used on any pH meter that has a female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These other types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

  • Conventional electrodes are normally single junction. As shown in the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, high acidity or alkalinity solutions, the positive flow of electrolyte through the junction is often reversed, allowing the sample solution to enter the reference chamber. If left unchecked, the reference electrode may become contaminated, resulting in complete failure of the electrode. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can easily precipitate in samples containing Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some silver chloride will precipitate on the outer surface of the junction. The result is a drifting reading from the sensor.

  • Hanna's double junction system, as the name implies, has two junctions, only one of which is in contact with the sample, as shown in the figure. Under adverse conditions, the same tendency for the sample to enter is evident. However, since the reference electrode system is physically separated from the intermediate electrolyte zone, contamination of the electrode is minimized. The double junction electrode also reduces the likelihood of junction clogging because the outer reference cell uses a “silver-free” fill solution. Since silver is not present, no precipitate that would clog the junction can form.

SKU HI1043B
Product Name Refillable Double Junction pH Electrode with BNC Connector - HI1043B
Quote Required Yes
Measurement Range pH
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl
Body Material glass
Tip / Shape spheric (dia
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 100°C (32 to 212°F) - HT
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Recommended Use high conductivity samples, hydrocarbon, paints, sea water, solvents, strong acid and base, tris buffer
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.