HI1043P

Electrodo de pH de vidrio de doble unión para alta temperatura

Electrodo de pH de doble unión rellenable con conector BNC + clavija

Product Overview

  • HI1043P is a glass body, refillable, double junction pH electrode with BNC and pin connectors. The pin connector is used to enable the CAL Check function of HI2221, HI2222 and HI2223 benchtop meters. The electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made of high temperature glass.

  • This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at high temperatures.

  • Refillable electrode

  • Double junction design

  • High temperature glass

  • Hanna Instruments offers a wide variety of pH electrodes that can be used in many different applications. The type of glass used to sense pH, bulb shape, body material, type of connection, reference type and electrolyte used are just some of the design considerations.

  • HI1043P uses high temperature (HT) glass, a spherical bulb, glass body, single ceramic frit, double junction, refillable with 3.5M KCl.

Figure 1 details:

  • High temperature glass formulation

  • Measuring pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten its life. A pH electrode with general purpose (GP) glass has a resistance of 100 megohms at 25°C, while HT glass has a resistance of about 400 megohms at 25°C. When HI1043P is used at high temperatures, the resistance decreases and approaches that of GP glass. HI1043P is suitable for samples from 0 to 100°C.

Figure 2 details:

  • Spherical bulb

  • The spherical bulb is for general purpose use. Other tip shapes include conical for penetration and flat tip for surface measurements.

Figure 3 details:

  • Glass body

  • The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easy to clean. The glass body also allows heat to be transferred quickly to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium, the more stable the reference potential.

Figure 4 details:

  • Single ceramic double junction reference

  • HI1043P is a double junction design. pH electrodes are available as single or double junction. See below for a complete description of the differences. The junction is also called a salt bridge and is a necessary part of the circuit. The movement of ions must flow through the junction for a stable reading. The outer reference has a single ceramic frit. Ceramic is a porous material that is easy to fuse with the glass body and has a similar coefficient of expansion. The single ceramic junction has a flow rate of 15-20μL/hour. Other junction types are available with higher flow rates and made from different materials.

Figure 5 details:

  • Refillable

  • HI1043P is a refillable probe. Since it is a double junction pH electrode, the fill solution is HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrodes. The lack of silver will prevent any silver precipitate from forming on the junction surface and clogging it. Clogging of the junction will result in drift and unstable readings.

Figure 6 details:

  • BNC + pin connector

  • HI1043P has a BNC and pin connector. The BNC connector is universal in that it can be used on any pH meter that has a female BNC probe input. The pin connector is used to enable the CAL Check function on the following benchtop pH meters; HI122, HI123, HI221, HI222, HI223, HI2221, HI2222 and HI2223.

Single junction vs. double junction pH electrodes

  • Conventional electrodes are normally single junction. As shown in the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of electrolyte through the junction is often reversed, resulting in the sample solution entering the reference chamber. If left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is clogging of the junction due to silver chloride (AgCl) precipitation. Silver can easily precipitate in samples containing Tris buffer or heavy metals. When the electrolyte solution contacts the sample, some silver chloride precipitates on the outer surface of the junction. The result is a drifting reading from the sensor.

  • Hanna's double junction system, as the name implies, has two junctions, only one of which is in contact with the sample, as shown in the figure. Under adverse conditions, the same tendency for sample to enter is evident. However, since the reference electrode system is physically separated from the intermediate electrolyte region, contamination of the electrode is minimized. Double junction electrodes also reduce the likelihood of junction clogging because the outer reference cell uses a “silver-free” fill solution. Since silver is not present, no precipitate is formed that would clog the junction.

SKU HI1043P
Product Name Refillable Double Junction pH Electrode with BNC + Pin Connector - HI1043P
Quote Required Yes
Measurement Range pH
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl
Body Material glass
Tip / Shape spheric (dia
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 100°C (32 to 212°F) - HT
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC + pin
Recommended Use high conductivity samples, hydrocarbon, paints, sea water, solvents, strong acid and base, tris buffer
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.