HI1332B

HI1332B

Electrodo combinado de pH de doble unión de PEI

Electrodo de pH de cuerpo de PEI rellenable con conector BNC

Product Overview

  • HI1332B is a PEI body double junction pH electrode with BNC connector. The electrode has a ceramic junction in the outer reference cell, and the pH sensing portion is made of general purpose glass, protected by an extension of the durable PEI body.

  • This design consideration makes it ideal for chemicals, quality control, field applications, and general purpose use.

  • Durable PEI body

  • Double junction design

  • Refillable electrode

Hanna Instruments offers a wide variety of pH electrodes designed for many different applications. The type of glass used to detect pH, bulb shape, body material, junction type, reference type, and the electrolyte used are just some of the design considerations.

The HI1332B uses general purpose (GP) glass, a spherical bulb, a polyetherimide (PEI) body, a single ceramic frit, and a double junction.

Figure 1 details:

  • General purpose glass formulation

  • Measuring pH at very high temperatures is harmful to the sensitive glass bulb and shortens its life. A pH electrode with general purpose (GP) glass has a resistance of 100 megohms at 25C, while LT glass has a resistance of approximately 25 megohms at 50C. As the temperature of the glass in the sample decreases, the resistance of LT glass will approach that of GP glass. If GP glass is used, the resistance will increase above the optimum range, causing increased impedance and ultimately affecting the measurement. The HI1332B is suitable for samples with a measurement range of 0 to 70C.°°°

Figure 2 details:

  • Spherical bulb

  • Spherical bulbs are used for general purpose applications. Other tip shapes include conical for penetration and flat tips for surface measurements.

Figure 3 details:

  • PEI body

  • The body of the HI1332B is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and, due to its durability, performs excellently in field measurements. The shield around the spherical glass tip minimizes damage from accidental impact or dropping of the electrode. PEI plastic is a high-quality plastic that is chemically resistant to many harsh chemicals.

Figure 4 details:

  • Double junction reference

  • A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment that houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver-free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or where silver precipitates may form on the junction.

Figure 5 details:

  • BNC connector

  • The HI1332B uses a BNC connector. This type of connector is universal in that it can be used with any pH meter that has a female BNC probe input. Other types of connectors include DIN, threaded, T-type, and 3.5mm, etc. These types of connectors tend to be proprietary connectors for specific types of meters and are not interchangeable.

  • Conventional electrodes are usually single junction. As shown in the figure above, these electrodes have only one junction between the internal reference wire and the external solution. Under adverse conditions such as high pressure, high temperature, or highly acidic or alkaline solutions, the positive flow of electrolyte through the junction often reverses, causing the sample solution to enter the reference chamber. If left unchecked, the reference electrode becomes contaminated, resulting in complete electrode failure. Another potential problem with single junction electrodes is junction clogging caused by silver chloride (AgCl) precipitation. In samples containing Tris buffer or heavy metals, silver readily precipitates. When the electrolyte solution contacts the sample, some AgCl precipitates on the outer surface of the junction. The result is drifting readings from the sensor.

  • Hanna's double junction system, as the name implies, has two junctions, with only one junction in contact with the sample, as shown in Figure 0. Under adverse conditions, the same intrusion trend is also evident. However, when the reference electrode system is physically separated from the intermediate electrolyte region, contamination of the electrode is minimized. Double junction electrodes also reduce the likelihood of junction clogging because the outer reference cell uses a “silver-free” fill solution. Since no silver is present, no precipitate can form to clog the junction.

SKU HI1332B
Product Name Refillable PEI Body pH Electrode with BNC Connector - HI1332B
Quote Required Yes
Measurement Range pH
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl
Body Material PEI
Tip / Shape spheric (dia
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 70°C (32 to 158°F) - GP
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use chemicals, field applications, quality control
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.