Product Overview
-
HI96753 is no longer available.
-
Below is a link to a new meter that has been upgraded with many advanced features, including an improved optical system, dot-matrix LCD, which provides a graphical tutorial mode to help users complete the measurement process, and is waterproof, including the cuvette assembly.
-
Both meters use the same reagents.
-
The HI96753 portable photometer is used to measure chloride. Hanna's portable photometers use an advanced optical system; the combination of a light-emitting diode (LED), a narrow-band interference filter, and a silicon photodetector ensures accurate photometric readings every time. Hanna's exclusive CAL Check™ feature uses ready-made NIST-traceable standards to verify meter validation and calibration. A dedicated cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
-
Features at a glance
-
CAL Check™ - allows performance verification and calibration of the meter using CAL Check NIST-traceable secondary standards.
-
GLP - records the date the last user calibration was performed.
-
Built-in timer - allows the use of a timer to ensure the chemical reaction uses the appropriate 3 minute 30 second reaction time. When the timer countdown ends, the meter will automatically take a reading. This feature ensures consistency between multiple users.
-
Indexing detent on the meter - the meter has a detent that allows a lock and key to engage with the cuvette cap. This ensures that the cuvette is consistently indexed (same position) so that the same path length is maintained for accurate results.
-
Cooling lamp indicator - in order to maintain narrow-band light, it is necessary to keep the temperature of the optical components consistent. This photometer has a cooling lamp indicator that is displayed for a short period before each measurement so that the components can cool and the highest possible accuracy can be obtained.
-
Error messages - displayed messages warn of problems, including no cap, over-range and under-range readings, and light source errors.
-
Auto shut-off - when the meter is in measurement mode, it automatically shuts off after 10 minutes of non-use. Prevents wasting battery if the meter is accidentally left on.
-
Battery status indicator
-
The instrument has a battery level indicator to show remaining battery life, as follows:
-
3 bars, 100% capacity
-
2 bars, 66% capacity
-
1 bar, 33% capacity
-
When the battery is below 10%, the battery icon flashes.
-
Measurement unit - the appropriate measurement unit is displayed together with the reading.
-
Chloride, as one of the major inorganic anions in water and wastewater, is frequently measured in various industries. Due to its corrosiveness, chloride levels in boiler systems and cooling towers are monitored to prevent damage to metal components. Chlorine is not currently known to be toxic to humans, but due to its negative effect on taste, chlorine in drinking water is monitored for aesthetic purposes. However, chloride can be toxic to plants. Chloride can be monitored in agricultural applications in certain regions of the world where salinity levels are known to be naturally high.
-
The HI96753 uses the mercuric thiocyanate (II) method to measure chloride concentrations below 20.0 mg/L (ppm). When both mercuric thiocyanate (II) and an iron-based reagent are added to a sample containing chloride, the sample will turn orange; the higher the concentration, the deeper the color. The associated color change is then analyzed colorimetrically according to the Beer-Lambert law. This principle states that light is absorbed by the complementary color, and the emitted radiation depends on the concentration. For chloride determination, a 466 nm (blue) narrow-band interference filter allows only blue light to be detected by the silicon photodetector, while ignoring all other visible light emitted by the LED. As the color change of the reacted sample increases, the absorbance of light at a specific wavelength also increases, while transmittance decreases.
-
The HI96753 is supplied as a kit (HI96753C), including:
-
Portable photometer
-
Sample cuvettes (2)
-
Caps
-
CAL Check™ standards with certificate
-
Cuvette cleaning cloth
-
Scissors
-
Rugged carrying case
-
The carrying case has thermoformed inserts for the meter and accessories
-
*Reagents are ordered separately
-
CAL Check™ standards with certificate
-
HI96753-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ feature.
-
Certificate of analysis provided
-
Lot number
-
Expiration date
-
Standard value at 25°C
-
NIST-traceable reference meter
-
Storage container provided
-
Lightproof
-
Protects against accidental breakage
| SKU | HI96753-web |
|---|---|
| Product Name | Chloride Portable Photometer - HI96753 |
| Quote Required | Yes |
| Chloride Range | 0.0 a 20.0 mg/L (ppm) |
| Chloride Resolution | 0.1 mg/L (ppm) |
| Chloride Accuracy | ±0.5 mg/L ±6% de la lectura |
| Chloride Method | Adaptación del método de tiocianato de mercurio (II) |
| Total Chlorine Range | 0.000 to 0.500 mg/L |
| Total Chlorine Resolution | 0.001 mg/L (ppm) |
| Total Chlorine Accuracy | ±0.020 mg/L ±3% of reading |
| Chlorine Method | adaptation of the USEPA method 330.5 |
| Photometer/Colorimeter Light Source | tungsten lamp |
| Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
| Battery Type/Life | 9V battery |
| Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Weight | 360g (12.7oz.) |
| Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
| Ordering Information | HI96761 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate, and instruction manual. |
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock
Resumen del proyecto
La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.
Retos técnicos
Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.
Configuración
El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.
Comportamiento
Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.
Alimentación y Bebidas — Hanna: caso de configuración desde stock
Situación en planta
Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.
El problema
La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.
Qué hicimos
Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultado operativo
En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.
Química y Farmacéutica — Hanna: caso de configuración desde stock
Contexto de aplicación
reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.
Limitaciones del proceso
la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.
Enfoque de suministro
La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.
Resultados en campo
La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.
Energía y Electricidad — Hanna: caso de configuración desde stock
Perfil del cliente
El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.
Dificultades clave
Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.
Implementación
El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Beneficio para el cliente
En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.
Recomendados similares
HANNA InstrumentsMedidor de conductividad portátil de rangos múltiples
HANNA InstrumentsFotómetro portátil de nitrógeno amoniacal de rango bajo
HANNA InstrumentsTurbidímetro portátil de rangos múltiples
HANNA InstrumentsMedidor de salinidad para acuarios de agua salada
HANNA InstrumentsAnalizador portátil de color de miel
HANNA InstrumentsFotómetro portátil de cloro libre
HANNA InstrumentsFotómetro portátil de cloro residual y total
HANNA Instruments