HI9811-5 is a multi-functional, waterproof, multi-parameter, portable meter, using the HI1285-5 electrode. The electrode features a unique DIN connector design and gel electrolyte, making it suitable for routine, greenhouse, hydroponic, water treatment, agricultural, boiler, cooling tower and other sample measurements. The meter features an oversized backlit LCD display showing measurement parameters and calibration indicators. Calibration can be easily performed using the knobs on the panel. Hanna's unique CAL CHECK TM calibration verification function allows users to quickly check the calibration status of the multi-parameter electrode at any time. 

  • New exterior design, oversized dual-line screen display, user-friendly design, ergonomic, excellent cost-performance ratio;

  • Simultaneously measures and displays pH/(EC/TDS) and ℃ measurements, with quick switching between pH, EC, and TDS;

  • Setup and calibration information prompts, manual acidity calibration, built-in 2 sets of standard calibration points; pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18;

  • Designed for field measurement, battery replacement is simple and quick, BEPS low battery error prevention system avoids erroneous measurements;

  • Suitable for providing laboratory-grade measurement results even in harsh environments.

Acidity 

   PH

     Measuring range 0.0 to 14.0 pH
     Resolution 0.1 pH
     Accuracy ±0.1 pH

   Conductivity EC

     Measuring range

0 to 6000 μS/cm

     Resolution 10 μS/cm
     Accuracy ±2% F.S.

  Total Dissolved SolidsTDS

     Measuring range

0 to 3000 ppm(mg/L)

     Resolution 10 ppm (mg/L)
     Accuracy ±2% F.S.

   Temperature

     Measuring range 0.0 to 60.0℃
     Resolution 0.1℃ 
     Accuracy ±0.5℃

  

  Temperature compensation

      pH

Automatic temperature compensation: -5.0 to 60.0℃(23.0 to 140.0  ℉)

      EC-TDS Compensation coefficient β=2.0% /℃

  Other specifications

      TDS factor 0.5ppm (mg/L)=1 μS/cm
      Calibration mode pH, EC/TDS single-point calibration
      Electrode type HI1285-5 polypropylene body with built-in temperature sensor pH-EC-TDS electrode (DIN connector, 1m cable length)
      Power supply 9V battery
      Operating environment 0℃ to 50℃(32 ℉ to 122 ℉),max 100% RH
      Dimensions & weight Dimensions: 145x80x36 mm, Weight: 230g

HI9811-5 meter, HI9812-5 meter, HI1285-5 polypropylene body with built-in temperature sensor pH-EC-TDS electrode, acidity-conductivity standard buffer solution kit, Chinese and English instruction manual