HI98168

Medidor de pH portátil de acidez del suelo

Medidor portátil pH-mV-°C°F [suelo y agricultura]
  • pH range: -2.000 to 20.000 pH; mV conversion: ±2000.0 mV; temperature: -20.0 to 120.0 °C, -4.0 to 248.0 °F

  • Designed specifically for acidity-pH measurement and analysis of samples in agriculture/gardening/soil industries

  • Large LCD screen display allows you to easily view pH, pH-mV, temperature measurement readings and instrument performance status from multiple angles; features a carefully designed Sensor Check™ function that allows users to check electrode status at any time;

  • Automatic endpoint locking function can lock stable readings on the LCD, making it convenient to read measurement results and record them; USB data interface, 200 data records [100 pH reading records, 100 mV reading records];

  • GLP function, query acidity-pH calibration data, up to five-point automatic recognition calibration and five-point custom calibration, built-in seven standard calibration points, messages on the graphical LCD, allowing easy and accurate calibration

  • New design, rugged and durable, built-in amplifier and temperature sensor conical glass acidity-pH electrode, convenient and quick setup and calibration modes, making the meter easier to operate.

Waterproof:

Ergonomic, rugged and durable waterproof (IP67) design, able to withstand harsh environments

Automatic calibration :

HI98168 can connect 5 points, including custom buffers. Calibration buffers are automatically recognized; after calibration, the buffer values used will be displayed on the screen

Calibration check:

  • Alerts the user to potential problems during calibration, including when to clean the electrode and possible buffer contamination.

  • Displays the overall condition of the pH electrode after calibration based on offset and slope characteristics

GLP data:

GLP data can be viewed at any time, including recorded readings. Calibration data includes date, time, pH calibration buffers, offset and slope.

Dot matrix LCD screen:

The high-contrast graphical LCD screen is easy to view in bright sunlight as well as in low-light areas with backlight. The combination of dedicated and virtual keys allows easy, intuitive operation of the meter in multiple languages.

On-demand logging:

Record up to 100 samples on demand (100 pH/100 mV)

PC connection:

Sealed optically isolated USB connects to a PC via micro USB cable and a PC running HI92000 software

Intuitive dot matrix display:

HI98168 features a backlit graphical LCD design. It has virtual keys, battery status indicator and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information related to the current meter operation and can be used at any stage of the setup or measurement process to display context-sensitive help.

Automatic buffer recognition:

  • Low battery indicator, optional auto-off.  

  • Auto power off: user selectable: 5, 10, 30, 60 minutes or can be disabled

Order No. HI98168
Product name Professional GroLine portable soil pH meter - HI98168
Quote required Yes
pH range -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
pH resolution 0.1; 0.01; 0.001 pH
pH accuracy ±0.1; ±0.01; ±0.002 pH
pH calibration Up to five-point calibration, providing seven standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers
pH input impedance 10¹² ohms
mV range ±2000 mV
mV resolution 0.1 mV
mV accuracy ±0.2 mV
Temperature range -20.0 to 120.0 °C (-4.0 to 248.0°F)
Temperature resolution 0.1°C; 0.1°F
Temperature accuracy ±0.4°C; ±0.8F (excluding probe error)
Temperature compensation Automatic or manual, -20.0 to 120.0 °C (-4.0 to 248.0°F)
Electrode HI12923 refillable pH electrode with conical tip, internal temperature sensor, quick-connect DIN connector and 1 m (3.3' cable)
Logging type On-demand logging
Logging memory Up to 200 samples (100 pH/100 mV)
Connectivity Optically isolated USB
Auto power off User selectable
Display LCD screen (backlit display)
Battery type/life 1.5V AA (4) / approx. 200 hours of continuous use without backlight (50 hours with backlight)
IP protection Protection class IP67
Environment 0 to 50°C (32 to 122°F); relative humidity 100% 
Dimensions 185 x 93 x 36.2 mm (5.7 x 3.6 x 1.4 in)
Weight 400 g (14.2 oz)
Ordering information HI98168 is supplied with HI12923 glass body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI7051M soil sample preparation solution (230 ml), HI700663 electrode cleaning solution soil sediment sachet (1), HI700664 electrode cleaning solution humus sediment sachet (1), HI 721319 grinding auger (1), 100 mL plastic beaker (2), 1.5V AA batteries (4 pcs), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.

HI98168 is supplied with HI12923 glass body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI7051M soil sample preparation solution (230 ml), HI700663 electrode cleaning solution soil sediment sachet (1), HI700664 electrode cleaning solution humus sediment sachet (1), HI 721319 grinding auger (1), 100 mL plastic beaker (2), 1.5V AA batteries (4 pcs), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.

Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.