Medidor multiparamétrico de calidad del agua de rango alto
Product Overview
-
HI991301
-
High-range water quality meter pH: 0.00 to 14.00 pH, temperature: 0.0 to 60.0 °C, 32.0 to 140.0 °F EC: 0.00 to 20.00 mS/cm, TDS: 0 to 2000 ppm (mg/L)
-
Multi-level LCD allows manual testing anytime, anywhere, with pH and temperature or EC/TDS and temperature readable at a glance from any angle, automatic calibration recognition, temperature compensation, and two-button operation simplifies the testing process for any user. The quick-connect DIN connector makes connecting and disconnecting the probe simple and convenient. The rubber coating protects the cable and provides a waterproof seal without twisting; suitable for providing laboratory-grade measurement results even in harsh environments
-
New exterior design, extra-large dual-line screen display, on-screen calibration procedure prompts;
-
User-friendly operation interface, stability indicator, two-button simple operation, convenient to use;
-
Simultaneously measures and displays pH/(EC/TDS) and °C, with quick switching between pH, EC, and TDS;
-
1-2 point automatic pH calibration recognition, with 2 sets of built-in pH standard calibration points; pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18
-
Conductivity and TDS single-point automatic calibration recognition, with built-in standard points;
-
EC: 1413 or 12880μS/cm; TDS: 1382, 1500ppm or 6.44 ppt
-
Automatic or manual temperature compensation, ensuring measurement precision and accuracy in different environments;
-
Battery replacement is simple and quick, BEPS low-battery error-prevention system avoids incorrect measurements;
-
Suitable for providing laboratory-grade measurement results even in harsh environments.
|
pH PH |
Measuring range | 0.0 to 14.0 pH | |
| Resolution | 0.1 pH | ||
| Accuracy | ±0.01 pH | ||
|
Conductivity EC |
Measuring range |
0.00 to 20.00 mS/cm |
|
| Resolution | 0.01 mS/cm | ||
| Accuracy | ±2% F.S. | ||
|
Total Dissolved Solids TDS |
Measuring range |
0.00 to 10.00 ppt(g/L) |
|
| Resolution | 0.01 ppt (g/L) | ||
| Accuracy | ±2% F.S. | ||
|
Temperature |
Measuring range | 0.0 to 60.0℃/32.0 to 140.0 ℉ | |
| Resolution | 0.1℃ /0.1 ℉ | ||
| Accuracy | ±0.5℃/±1 ℉ | ||
|
Calibration mode |
pH |
1-2 point automatic calibration recognition, with 2 sets of built-in standard calibration points pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18 |
|
| EC single-point calibration | 1413μS/cm | ||
| TDS single-point calibration | 1382, 1500ppm | ||
|
Temperature compensation |
pH |
Automatic temperature compensation: -5.0 to 60.0℃(23.0 to 140.0 ℉) |
|
| EC-TDS | Compensation coefficient β=0.0-2.4% /℃ adjustable, increment 0.1 | ||
|
Other specifications |
TDS factor | Adjustment range: 0.45 to 1.00, increment 0.1 (default: 0.50) | |
| Electrode type | HI1288 PVC body with built-in temperature sensor pH-EC-TDS multiparameter electrode | ||
| Power supply type | 3x1.5V AAA batteries, auto power-off after 8 minutes of no operation | ||
| Operating environment | 0℃ to 50℃(32 ℉ to 122 ℉),max 100% RH | ||
| Dimensions | Meter dimensions: 152x58x30mm | ||
| Weight | Meter weight: 205g | ||
-
Meter HI991300 or HI993301, HI1288 dedicated built-in temperature sensor pH-EC-TDS multiparameter electrode, pH-conductivity standard buffer solution kit, Chinese and English instruction manual
-
The HI991301 is designed to measure pH, conductivity (EC), total dissolved solids (TDS), and temperature using a single probe. From setup to calibration, everything can be done with just two buttons. The meter is waterproof with IP 67 protection class.
-
The HI12883 pre-amplified multiparameter probe features easily cleanable sensors and a renewable cloth junction to extend probe life. To prevent interference from transient electrical noise, a solid-state amplifier is integrated into the HI12883.
-
User-selectable features include different TDS factors from 0.45 to 1.00 and a temperature coefficient (β) range from 0.0 to 2.4% for greater consistency and repeatability. Standardized buffer recognition values are also selectable.
-
These instruments fit easily in the palm of your hand, and the bottom probe connection ensures the electrode cable does not get in your way. The large multi-level LCD displays the primary reading, temperature, and calibration

| SKU | HI991301 |
|---|---|
| Product Name | Portable Waterproof pH/EC/TDS Meter (High Range) - HI991301 |
| Quote Required | Yes |
| pH Range | -2.00 to 16.00 pH; -2.0 to 16.0 pH |
| pH Resolution | 0.01 pH; 0.1 pH |
| pH Accuracy | ±0.02 pH; ±0.1 pH |
| pH Calibration | automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) |
| pH Temperature Compensation | automatic 0 to 50 °C; 32 to 122 °F |
| pH CAL Check (electrode diagnostics) | probe condition indicator |
| pH Sensor Check | yes |
| mV Range | ±825 mV (pH‐mV) |
| mV Resolution | 1 mV (pH‐mV) |
| mV Accuracy | ±1 mV (pH‐mV) |
| EC Range | 0.00 to 20.00 mS/cm |
| EC Resolution | 0.01 mS/cm |
| EC Accuracy | ±2% F.S. |
| EC Calibration | automatic, one-point at 12.88 mS/cm |
| TDS Range | 0.00 to 10.00 ppt (g/L) |
| TDS Resolution | 0.01 ppt (g/L) |
| TDS Accuracy | ±2% F.S. |
| TDS Calibration | automatic |
| EC/TDS Temperature Compensation | automatic |
| Temperature Correction Coefficient | β selectable from 0.0 to 2.4 %/ °C with 0.1 increments |
| EC to TDS Conversion Factor | selectable from 0.45 to 1.00 with 0.01 increments |
| Temperature Range | ‐5.0 to 105.0 °C; 23.0 to 221.0 °F |
| Temperature Resolution | 0.1°C; 0.1°F |
| Temperature Accuracy | ±0.5°C; ±1°F |
| pH/EC Probe | HI12883 PVC body, pre-amplified multiparameter probe with internal temperature sensor, quick connect DIN connector and 1m cable |
| Automatic Shut-Off | user selectable |
| Battery Type/Life | 1.5V (3) AAA / approximately 600 hours of continuous use |
| IP Protection | IP67 |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
| Weight | 196 g (6.91 oz.) |
| Ordering Information | HI991301 is supplied complete with HI12883 pH/EC/temperature probe, pH 4.01 calibration buffer sachet (1), pH 7.01 calibration buffer solution sachet (1), HI70030 12.88 mS/cm calibration solution sachet (1), HI70038 6.44 ppt calibration solution sachet (1), HI700601 electrode cleaning solution sachet (2), 100 mL beaker (1), batteries, calibration certificates for both meter and probe, instruction manual, and rugged thermoformed carrying case. |
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock
Resumen del proyecto
La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.
Retos técnicos
Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.
Configuración
El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.
Comportamiento
Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.
Alimentación y Bebidas — Hanna: caso de configuración desde stock
Situación en planta
Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.
El problema
La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.
Qué hicimos
Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultado operativo
En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.
Química y Farmacéutica — Hanna: caso de configuración desde stock
Contexto de aplicación
reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.
Limitaciones del proceso
la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.
Enfoque de suministro
La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.
Resultados en campo
La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.
Energía y Electricidad — Hanna: caso de configuración desde stock
Perfil del cliente
El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.
Dificultades clave
Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.
Implementación
El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Beneficio para el cliente
En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.
Recomendados similares
HANNA InstrumentsMedidor de conductividad portátil de rangos múltiples
HANNA InstrumentsFotómetro portátil de nitrógeno amoniacal de rango bajo
HANNA InstrumentsTurbidímetro portátil de rangos múltiples
HANNA InstrumentsMedidor de salinidad para acuarios de agua salada
HANNA InstrumentsAnalizador portátil de color de miel
HANNA InstrumentsFotómetro portátil de cloro libre
HANNA InstrumentsFotómetro portátil de cloro residual y total
HANNA Instruments