Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

HI991301

HI991301

Medidor multiparamétrico de calidad del agua de rango alto

Medidor de calidad del agua de rango alto, pH: 0.00 a 14.00 pH, temperatura: 0,0 a 60.0 °C, 32.0 a 140.0 °F, conductividad EC: 0.00 a 20.00 mS/cm, sólidos disueltos totales TDS: 0 a 2000 ppm (mg/L)

Product Overview

  • HI991301

  • High-range water quality meter pH: 0.00 to 14.00 pH, temperature: 0.0 to 60.0 °C, 32.0 to 140.0 °F EC: 0.00 to 20.00 mS/cm, TDS: 0 to 2000 ppm (mg/L)

  • Multi-level LCD allows manual testing anytime, anywhere, with pH and temperature or EC/TDS and temperature readable at a glance from any angle, automatic calibration recognition, temperature compensation, and two-button operation simplifies the testing process for any user. The quick-connect DIN connector makes connecting and disconnecting the probe simple and convenient. The rubber coating protects the cable and provides a waterproof seal without twisting; suitable for providing laboratory-grade measurement results even in harsh environments

  • New exterior design, extra-large dual-line screen display, on-screen calibration procedure prompts;

  • User-friendly operation interface, stability indicator, two-button simple operation, convenient to use;

  • Simultaneously measures and displays pH/(EC/TDS) and °C, with quick switching between pH, EC, and TDS;

  • 1-2 point automatic pH calibration recognition, with 2 sets of built-in pH standard calibration points; pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18

  • Conductivity and TDS single-point automatic calibration recognition, with built-in standard points;

  • EC: 1413 or 12880μS/cm; TDS: 1382, 1500ppm or 6.44 ppt

  • Automatic or manual temperature compensation, ensuring measurement precision and accuracy in different environments;

  • Battery replacement is simple and quick, BEPS low-battery error-prevention system avoids incorrect measurements;

  • Suitable for providing laboratory-grade measurement results even in harsh environments.

   pH 

   PH

     Measuring range 0.0 to 14.0 pH
     Resolution 0.1 pH
     Accuracy ±0.01 pH

   Conductivity EC

     Measuring range

0.00 to 20.00 mS/cm

     Resolution 0.01 mS/cm
     Accuracy ±2% F.S.

  Total Dissolved Solids 

  TDS

     Measuring range

0.00 to 10.00 ppt(g/L)

     Resolution 0.01 ppt (g/L)
     Accuracy ±2% F.S.

   Temperature

     Measuring range 0.0 to 60.0℃/32.0 to 140.0 ℉
     Resolution 0.1℃ /0.1 ℉
     Accuracy ±0.5℃/±1 ℉

   Calibration mode

     pH

1-2 point automatic calibration recognition, with 2 sets of built-in standard calibration points pH4.01, 7.01,

10.01 and pH4.01, 6.86, 9.18

     EC single-point calibration 1413μS/cm
     TDS single-point calibration 1382, 1500ppm

  

  Temperature compensation

     pH

Automatic temperature compensation: -5.0 to  60.0℃(23.0 to 140.0 ℉)

     EC-TDS Compensation coefficient β=0.0-2.4% /℃ adjustable, increment 0.1

  Other specifications

     TDS factor Adjustment range: 0.45 to 1.00, increment 0.1 (default: 0.50)
     Electrode type HI1288 PVC body with built-in temperature sensor pH-EC-TDS multiparameter electrode
     Power supply type 3x1.5V AAA batteries, auto power-off after 8 minutes of no operation
     Operating environment 0℃ to 50℃(32 ℉ to 122 ℉),max 100% RH
     Dimensions Meter dimensions: 152x58x30mm  
     Weight Meter weight: 205g
  • Meter HI991300 or HI993301, HI1288 dedicated built-in temperature sensor pH-EC-TDS multiparameter electrode, pH-conductivity standard buffer solution kit, Chinese and English instruction manual

  • The HI991301 is designed to measure pH, conductivity (EC), total dissolved solids (TDS), and temperature using a single probe. From setup to calibration, everything can be done with just two buttons. The meter is waterproof with IP 67 protection class.

  • The HI12883 pre-amplified multiparameter probe features easily cleanable sensors and a renewable cloth junction to extend probe life. To prevent interference from transient electrical noise, a solid-state amplifier is integrated into the HI12883.

  • User-selectable features include different TDS factors from 0.45 to 1.00 and a temperature coefficient (β) range from 0.0 to 2.4% for greater consistency and repeatability. Standardized buffer recognition values are also selectable.

  • These instruments fit easily in the palm of your hand, and the bottom probe connection ensures the electrode cable does not get in your way. The large multi-level LCD displays the primary reading, temperature, and calibration

SKU HI991301
Product Name Portable Waterproof pH/EC/TDS Meter (High Range) - HI991301
Quote Required Yes
pH Range -2.00 to 16.00 pH; -2.0 to 16.0 pH
pH Resolution 0.01 pH; 0.1 pH
pH Accuracy ±0.02 pH; ±0.1 pH
pH Calibration automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
pH Temperature Compensation automatic 0 to 50 °C; 32 to 122 °F
pH CAL Check (electrode diagnostics) probe condition indicator
pH Sensor Check yes
mV Range ±825 mV (pH‐mV)
mV Resolution 1 mV (pH‐mV)
mV Accuracy ±1 mV (pH‐mV)
EC Range 0.00 to 20.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% F.S.
EC Calibration automatic, one-point at 12.88 mS/cm
TDS Range 0.00 to 10.00 ppt (g/L)
TDS Resolution 0.01 ppt (g/L)
TDS Accuracy ±2% F.S.
TDS Calibration automatic
EC/TDS Temperature Compensation automatic
Temperature Correction Coefficient β selectable from 0.0 to 2.4 %/ °C with 0.1 increments
EC to TDS Conversion Factor selectable from 0.45 to 1.00 with 0.01 increments
Temperature Range ‐5.0 to 105.0 °C; 23.0 to 221.0 °F
Temperature Resolution 0.1°C; 0.1°F
Temperature Accuracy ±0.5°C; ±1°F
pH/EC Probe HI12883 PVC body, pre-amplified multiparameter probe with internal temperature sensor, quick connect DIN connector and 1m cable
Automatic Shut-Off user selectable
Battery Type/Life 1.5V (3) AAA / approximately 600 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)
Weight 196 g (6.91 oz.)
Ordering Information HI991301 is supplied complete with HI12883 pH/EC/temperature probe, pH 4.01 calibration buffer sachet (1), pH 7.01 calibration buffer solution sachet (1), HI70030 12.88 mS/cm calibration solution sachet (1), HI70038 6.44 ppt calibration solution sachet (1), HI700601 electrode cleaning solution sachet (2), 100 mL beaker (1), batteries, calibration certificates for both meter and probe, instruction manual, and rugged thermoformed carrying case.
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.