107072	AmmoLyt® Plus SET/Comp

AmmoLyt® Plus SET/Comp

WTW 107072
Robust digital ammonium sensor for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system, delivered with VARiON® Ref, VARiON®Plus NH4 and VARiON®Plus K electrodes. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: SACIQ connection cable (Please order separately). 用于离子选择性电极(原位测量)的坚固数字铵传感器,与IQ sensor NET系统配合使用,与VARiON®Ref、VARiON™Plus NH4和VARiON?Plus K电极一起交付。内置防雷、前置放大器和温度传感器。不包括:SACIQ连接线(请单独订购)。

Digital ISE sensor for ammonium, connectable to the IQ SENSOR NET

Ammonium measurement directly in the medium without sample preparation and sample transfer. Measurement of centrate and other process waters up to 2,000 mg/l NH4-N:

  • Calibration free, long-term stability
  • No chemicals
  • Short response times

The ISE sensor AmmoLyt®Plus 700 IQ allows ammonium measurement directly in the process. Time-consuming steps such as sampling and preparation are eliminated. For stable measured values, the interference substance potassium is compensated simultaneously and can be displayed if needed. An energy-optimized operation by a suitable regulation of the blower aggregates is made possible by this ISE sensor. This will help effectively reduce operating costs of the system, which is amortized by the system in a very short time. Starting now, you will be able to reliably determine centrate and other process water with high ammonium load up to 2.000 mg/l NH4-N with the AmmoLyt®Plus!

Measuring method

Electrochemical

Appropriate Electrode

Reference electrode VARiON® Ref, Measuring electrode VARiON®Plus NO3, Compensation electrode VARiON®Plus Cl

Measuring range/Resolution

NH4-N: 1 ... 2,000 mg/l / 1 mg/l; 0.1 ... 100 mg/l / 0.1 mg/l
NH4+: 1 ... 2,580 mg/l / 1 mg/l; 0.1 ... 129.0 mg/l / 0.1 mg/l

Compensation Range

K+: 0.1 ... 1,000 mg/l / 0.1 mg/l

Measuring Accuracy in laboratory standard solutions

± 5 % of measured value ± 0.2 mg/l in standard solutions

Calibration Procedures

Matrix adjustment against any reference value, 2-point-calibration possible with multiple standard solution

Working Life (typically)

Reference electrode: 18 months,
measuring and compensation electrode: 18 months (in typical application - municipal sewage plants)

Temperature Measurement and Compensation

Integrated NTC thermistor, 
Range 32 °F … 104 °F (0 °C … +40 °C), Accuracy ±0.5 K, Resolution 0.1 K, t95 < 20 s

Pressure Resistance

Maximum 0.2 bar (incl. SACIQ sensor connection cable, with installed electrodes)

Ambient Conditions

Operating temperature: 32 °F … 104 °F (0 °C … +40 °C), storing temperature: 32 °F … 104 °F (0 °C … +40 °C)

Electrical connections

2-wire shield cable with quick fastener to sensor

Electromagnetic Compatibility

EN 61326, Class B, FCC Class A;
Intended for indispensable operation

Certifications

CE

Mechanical

Sensor body: V4A stainless steel 1.4571 Protective cup: POM
Temperature sensor: V4A stainless steel 1.4571 Protection rating: IP 68 (0.2 bar, with installed electrodes)
Electrode connector: POM

Weight

Approx. 1.48 lb (670 g, without electrode, without sensor connection cable)

Warranty

AmmoLyt®Plus 700 IQ: 2 years
Electrodes: 1 year for defects of quality